indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
for the specific
05/2016 Subject to change
Preface
Scope
Note
This document belongs to the device and will also be required for repeat commissioning.
Keep all supplied and supplementary documentation for the entire service life of the
Provide all associated documents to any future owner of the device.
Style conventions
Style Convention
Scope
menu commands.
<F1>, <Alt+P>
Keyboard operation
Note
A note
or a specific section of the manual to which you should pay particular attention.
These compact operating instructions apply to the following HMI devices in conjunction with
the WinCC software package:
● TP700 Comfort Outdoor, article number 6AV2124-0GC13-0AX_
● TP1500 Comfort Outdoor, article number 6AV2124-0QC13-0AX_
"_" stands for the variant key of the article number.
These compact operating instructions describe the technical differences of the Outdoor
devices to the corresponding standard devices.
The information in these compact operating instructions take precedence in terms of their
binding character over the statements in the following underlying operating instructions, the
release notes and the online help.
Operating instructions on the Comfort Panels
(http://support.automation.siemens.com/WW/view/en/49313233
"Add screen"
"File > Edit" Operational sequences, for example, menu commands, shortcut
Please observe notes labeled as follows:
• Terminology that appears in the user interface, for example,
dialog names, tabs, buttons, menu commands
• Required input, for example, limits, tag values.
• Path information
)
device.
contains important information about the product described in the manual and its use,
7 Technical information ............................................................................................................................ 25
A Technical Support ................................................................................................................................. 36
Index .................................................................................................................................................... 37
7.1 Certificates and approvals ..................................................................................................... 25
SIMATIC Comfort Outdoor devices with glass touch screen and powder-coated, UV-resistant
aluminum front are designed for use in indoor and outdoor areas, for example, in the fields of
Oil&Gas, Marine or Refrigeration Technology.
All devices offer the same excellent functionality and are configured exclusively with the
innovative HMI software, WinCC. The engineering software is integrated in the engineering
framework, "Totally Integrated Automation Portal".
Slots for SD
memory cards
device. The safety tab is not required with the Comfort Outdoor devices.
1.2
Software requirements
1.2 Software requirements
• External dimensions of the front and mounting cutout correspond to the
standard product
• Durable powder coating
• High UV resistance
• GFG (Glass-Film-Glass) touch screens, analog resistive
• Manual or automatic brightness control with brightness sensor
• High-resolution TFT display in widescreen format with 16 million colors
• Suitable for use in daylight
• Anti-reflective and bonded for glare-free reading
• Resistive single touch screen
• Suitable for operation with gloves, pen and fingers
• 2 PROFINET interfaces
• 1 PROFIBUS interface
• USB 2.0 ports:
– 2 x USB host interface (type A)
– 1 x USB device interface (type mini B)
The Comfort Outdoor devices are deeper than the corresponding Comfort HMI
device.
Read the information in the following sections:
• Preparing the mounting cutout (Page 17)
• Dimension drawings (Page 29)
The protection mechanism of the SD memory card for the Comfort Outdoor
devices is mechanically differently than that of the corresponding Comfort HMI
You require the software WinCC V13 SP1 (TIA Portal) Update 6 with the Hardware Support
Package "HSP0149 HMI TP700_1500 Comfort Outdoor" or later versions. You can find the
software under Technical Support on the Internet.
The following components are included in the scope of delivery of the HMI device.
HMI device
Installation instructions
(Quick Install Guide)
Mounting clips
Strain relief Example: Strain relief
Aluminum mounting clip 8 TP700 Comfort Outdoor
Steel mounting clip 12 TP1500 Comfort Outdoor
1
1
1 TP700 Comfort Outdoor
Power supply terminal Connector, female, 2-pin, type 1
Some components in the scope of delivery are also available as accessories, see
"Accessories" section in the Comfort Panels operating instructions or directly in the Industry
Mall (https://mall.industry.siemens.com
The figure below shows the interfaces of the HMI devices.
Use the X1 or X60 interface to connect a configuration PC. Use the X61 / X62 interfaces to
connect peripheral devices such as a printer or keyboard. Use the X90 interface to connect a
loudspeaker.
You can fasten the USB and PROFINET connecting cables to the rear panel of the
HMI device with cable ties.
Secure the cables with a separate strain relief for the TP700 Comfort Outdoor. Install the