Siemens SIMATIC PC 870,SIMATIC PC 670 Equipment Manual

Preface, Table of Contents
Product Overview
1
Description of Device
2
Mounting
3
Maintenance
4
Appendices
A
Guidelines for ESD
B
Index
This manual is part of the documentation package with the order number 6AV7691–0AB00–0AB0
Edition 07/01
Panel PC 670 / 870 Operating Unit
Equipment Manual
SIMATIC PC
This manual contains information which you must observe for your personal safety and to prevent material damage. The information is denoted by a warning triangle and is differentiated as follows, depending on the degree of danger:
!
Danger
indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury .
!
Warning
indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
!
Caution
used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury .
Caution
used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
Notice
indicates a situation which, if not avoided, could give rise to an undesirable result or state.
Note
is an important piece of information about the product, the handling of the product or a particular part of the documentation to which attention is to be drawn.
Only qualified personnel are permitted to start up and operate the device. Quali­fied personnel for the purposes of the safety information in this manual are persons who hold the necessary authorization to install, ground and label devices, systems and circuits in accordance with the standards of safety engineering.
Please note the following:
!
Warning
The device may only be used for the application cases specified in the catalog and the technical description and may only be used in combination with third-party equipment and components recommended or approved by Siemens.
Startup must not take place until it is established that the machine which is to ac­commodate this component is in conformity with the guideline 98/37 EC.
Appropriate transport, and appropriate storage, installation and assembly , as well as careful operation and maintenance, are required to ensure that the product op­erates perfectly and safely .
Safety information
Qualified personnel
Correct usage
You will find the registered trademarks of Siemens AG in the preface. The remaining marks used in this publication (or on the CD) may be trademarks, the use of which by third parties for their own purposes could violate the rights of the owner.
Publisher: A&D PT1D1 Editor: A&D SE ES4.
Trademarks
Impressum
We have checked the content of this publication for compliance with the described hardware and software. However, discrepancies cannot be ex­cluded, with the result that we cannot guarantee total compliance. The infor­mation in this publication is, however, checked regularly, and any necessary corrections are included in the following editions. We welcome any sugges­tions for improvement.
Exclusion of liabilityCopyright Siemens AG 2001 All rights reserved
The transmission and reproduction of this documentation and the exploitation and communication of its contents are not permitted without express authority. Offenders will be liable for compensation for damage. All rights reserved, especially in the case of the granting of a patent or registration of a utility model or design
Siemens AG Automation & Drives SIMATIC Human Machine Interface Postfach 4848, D-90327 Nürnberg
Siemens AG 2001 Subject to technical changes.
Siemens Aktiengesellschaft Order No. 6AV7691–0AB00–0AA0
i
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Preface
Purpose of the manual
This manual contains information which you require when using the operating unit of the SIMATIC Panel PC 670 or PC 870. With this information you can:
become acquainted with the functions and components of the operating unit,separate the operating unit from the computing unit,install the Panel PC,perform upgrades and install spare parts, providing you fulfill the necessary
conditions.
Target group
The manual is supplied as an electronic document in PDF-format together with the SIMATIC Panel PC 670 or PC 870 and has been written for the following readers:
users who commission the device themselves or work with the Panel PC
(editing, testing),
service and maintenance engineers who perform conversions and install
upgrades or spare parts.
Preface
ii
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/01
Documentation
Commissioning Instructions
The Commissioning Instructions are supplied as a paper document. The docu­ment is intended for commissioning engineers and system administrators. The Commissioning Instructions describe briefly the most important steps for commissioning the hardware and software.
SIMATIC Panel PC 670/PC 870 Operating Unit Equipment Manual
The manual is supplied on CD together with the SIMATIC Panel PC 670 or PC 870 as an electronic document in PDF-format. It is intended for the commis­sioning engineers and service and maintenance technicians who install the Panel PC and perform maintenance work on the operating unit. Furthermore, the Equipment Manual provides an overview of how to use the controls of the operating unit.
SIMATIC Panel PC 670 Computing Unit Equipment Manual
The manual is supplied on CD together with the SIMATIC Panel PC 670 as an electronic document in PDF-format. It is intended for the commissioning engi­neers, and service and maintenance technicians who install upgrades or per­form error analyses on the computing unit.
SIMATIC Panel PC 870 Computing Unit Equipment Manual
The manual is supplied on CD together with the SIMATIC Panel PC 870 as an electronic document in PDF-format. It is intended for the commissioning engi­neers, and service and maintenance technicians who install upgrades or per­form error analyses on the computing unit.
Notation
The following conventions are used in this manual:
Motor off Text that is displayed on the operating unit is printed in
Courier typeface.
Variable
Symbolic names that stand for variable values appearing on the screen are printed in Courier italic typeface.
Screens
Selectable functions are printed in standard italic typeface.
ESC Names of keys and buttons are shown in a different
typeface.
History
Edition Comments
03/00 Initial release of the equipment manual SIMATIC Panel PC 670 –
Operating Unit.
07/01 Initial release of the equipment manual SIMATIC Panel PC
670/870 – Operating Unit
Preface
iii
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Trademarks
The following names are registered trademarks of Siemens AG:
SIMATIC
SIMATIC HMI
HMI
ProTool
ProTool/Lite
ProTool/Pro
SIMATIC Multi Panel
SIMATIC Multifunctional Platform
MP 270
ProAgent
Other Sources of Assistance
In case of technical queries, please get in touch with your Siemens contact partner at the agency or branch office responsible for your area.
Customer Support, Technical Support
Available round the clock, worldwide:
Johnson City
Nuremberg
Singapore
SIMATIC Hotline
Preface
iv
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/01
Worldwide (Nuremberg) Technical Support
(FreeContact)
Local time: Mon.-Fri. 7:00 to17:00 Telephone: +49 (180) 5050-222 Fax: +49 (180) 5050-223 E-Mail: techsupport@
ad.siemens.de
GMT: +1:00
Worldwide (Nuremberg) Technical Support
(fee–based, only with SIMATIC Card) Local time: Mon.-Fri. 0:00 to 24:00
Telephone: +49 (911) 895-7777 Fax: +49 (911) 895-7001 GMT: +01:00
Europe / Africa (Nuremberg) Authorization
Local time: Mon.-Fri. 7:00 to17:00 Telephone: +49 (911) 895-7200 Fax: +49 (911) 895-7201 E-Mail: authorization@
nbgm.siemens.de
GMT: +1:00
America (Johnson City) Technical Support and
Authorization
Local time: Mon.-Fri. 8:00 to19:00 Telephone: +1 423 461-2522 Fax: +1 423 461-2289 E-Mail: simatic.hotline@
sea.siemens.com
GMT: –5:00
Asia / Australia (Singapore) Technical Support and
Authorization
Local time: Mon.-Fri. 8:30 to17:30 Telephone: +65 740-7000 Fax: +65 740-7001 E-Mail: simatic.hotline@
sae.siemens.com.sg
GMT: +8:00
The languages of the SIMATIC Hotlines are generally German and English, though French, Italian and Spanish are also spoken on the authorization hotline.
SIMATIC Customer Support Online Services
The SIMATIC Customer Support team offers you substantial additional information about SIMATIC products via its online services:
General current information can be obtained
– from the Internet under http://www.ad.siemens.de/simatic
Current product information and downloads which you may find useful are
available : – from the Internet under http://www.ad.siemens.de/simatic-cs – or via the Bulletin Board System (BBS) in Nuremberg (
SIMATIC Customer
Support Mailbox)
under the number +49 (911) 895-7100.
To access the mailbox, use a modem with up to V.34 (28.8 Kbps) with the parameters set as follows: 8, N, 1, ANSI; or dial in via ISDN (x.75, 64 Kbps)
You can find your local customer service representative for Automation & Drives
in our customer service representative database – on the Internet under
http://www3.ad.siemens.de/partner/search.asp
Table of Contents
v
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Table of Contents
Preface i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Product Overview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Panel PC 670: Computing and operating units 1-2. . . . . . . . . . . . . . . . . . . . . . .
1.2 Panel PC 870: Computing and operating units 1-4. . . . . . . . . . . . . . . . . . . . . . .
2 Description of Device 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Operating units with key-based front panels 2-2. . . . . . . . . . . . . . . . . . . . . . . . .
2.1.1 Status indicators 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.2 Keyboard 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.3 Integrated mouse 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Operating units with touchscreen front panels 2-6. . . . . . . . . . . . . . . . . . . . . . .
2.3 Interfaces 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.1 Front-side USB interface 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.2 Rear-side interfaces 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.3 Interface assignment 2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4 Device dimensions 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.1 Dimensions of Panel PC 670 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.2 Dimensions of Panel PC 870 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Mounting 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 Mounting cut-out 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 Panel PC 670 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.2 Panel PC 870 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Installation 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 Panel PC 670 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.2 Panel PC 870 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Maintenance 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Spare parts and accessories 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.1 Spare parts 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.2 Accessories 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Detaching the operating unit from the computing unit 4-2. . . . . . . . . . . . . . . . .
4.2.1 Panel PC 670 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.2 Panel PC 870 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Replacing soft key labeling
(operating units with key-based front panels only) 4-6. . . . . . . . . . . . . . . . . . . .
A Appendix A: Technical Data A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.1 Technical data of operating unit A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2 Keyboard table (operating units with key-based front panels) A-3. . . . . . . . . .
Table of Contents
vi
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/01
B Appendix B: ESD Guidelines B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index Index-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Product Overview
The SIMATIC Panel PC 670 and PC870 are industry-standard PC plat­forms for demanding tasks in the field of PC-based automation. They are designed as fitted units for local use directly on the machine in
switch cabinets/consoles19” cabinets/racks.
The Panel PC consists of the two components computing unit and operating unit.
The present equipment manual basically describes the specific charac­teristics of the operating unit, but also makes reference to the complete unit where necessary – for example, with regard to the dimensions for mounting, maintenance and in the technical data
Usage
1
Product Overview
1-2
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/01
1.1 Panel PC 670: Computing and operating units
The computing unit is screwed to the rear of the operating unit with two mounting rails and can be separated from the latter. Figure 1-1 shows an example of the complete device and indicates the connection between the computing unit and the operating unit (2 of the 4 screw joints are marked with circles). Details on how to separate the two components are contained in Section 4.2.1.
Computing unit
Operating unit
Fig. 1-1 Panel PC: Computing unit and operating unit
The SIMATIC Panel PC 670 can be supplied with various front panels, which differ by way of their display size and style of operation, which is either by membrane keyboard or touchscreen.
The following different versions are available:
Keyboard versions
Color display with back-lighting
– 10.4” TFT screen; 640 x 480 pixel resolution
or
– 12.1” TFT screen; 800 x 600 pixel resolution
or
– 15.1” TFT screen; 1024 x 768 pixel resolution
Membrane keyboard with alpha, numeric, cursor and control keypad
Brief description
Product Overview
1-3
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Function keys/soft keys
– 2 x 8 vertical rows of key s with soft - k ey and optional direc t –k ey
functions – 2 x 10 horizontal rows of keys with soft-key functions – labeling strips for the rows of soft keys
Shift key for switching to the second level of key functionsIntegrated piezo mouseStatus LEDs for power supply and temperatureUSB interface on front side
for connecting external peripheral devices
Degree of protection IP 54 / IP 65 1) depending on version  Mounting: Clamps on rear side or 19” screw fixing
Touchscreen versions
Color display with back-lighting
– 12.1” TFT screen; 800 x 600 pixel resolution
or – 15.1” TFT screen; 1024 x 768 pixel resolution
Status LEDs for power supply and temperatureUSB interface on front side
for connecting external peripheral devices 2)
Degree of protection IP 54 / IP 65 / NEMA 4 1)
depending on version
Mounting: Clamps on rear side;
alternatively 19” screw fixing for 15.1” version
_______________________________________________________
1
) see Technical Data (Appendix)
2
) not for NEMA–standard versions (see Technical Data in Appendix)
Product Overview
1-4
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/01
1.2 Panel PC 870: Computing and operating units
The computing unit is screwed to the rear of the operating unit with two mounting rails and can be separated from the latter (see Section 4.2.2). Figure 1-2 shows an example of the complete device:
Operating unit Computing unitComputing unit
Fig. 1-2 Panel PC 870: Complete device, comprising computing unit and
operating unit
The SIMATIC Panel PC 870 can be supplied with various front panels,
which differ by way of their display size and style of operation, which is
either by membrane keyboard or touchscreen.
The following different versions are available:
Keyboard versions
Color display with back-lighting
– 12.1” TFT screen; 800 x 600 pixel resolution
or
– 15.1” TFT screen; 1024 x 768 pixel resolution
Membrane keyboard with alpha, numeric, cursor and control keypad
Function keys/soft keys
– 2 x 8 vertical rows of key s with soft - k ey and optional direc t - k ey
functions – 2 x 10 horizontal rows of keys with soft-key functions – labeling strips for the rows of soft keys
Brief description
Product Overview
1-5
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual Edition 07/01
Shift key for switching to the second level of key functionsIntegrated piezo mouseStatus LEDs for power supply and temperatureUSB interface on front side
for connecting external peripheral devices
Degree of protection IP 54 / IP 65 1) depending on version  Mounting: Clamps on rear side or 19” screw fixing
Touchscreen version
Color display with back-lighting,
15.1” TFT screen; 1024 x 768 pixel resolution
Status LEDs for power supply and temperatureUSB interface on front side
for connecting external peripheral devices 2)
Degree of protection IP 54 / IP 65 / NEMA 4 1)
depending on version
Mounting: Clamps on rear side;
alternatively 19” screw fixing
______________________________________________________________
1
) see Technical Data (Appendix)
2
) not for NEMA–standard versions (see Technical Data in Appendix)
Loading...
+ 33 hidden pages