This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: C79000-G8976-C301
Ⓟ 12/2012 Technical data subject to change
Description of the device ........................................................................................................................... 9
Please check that the consignment you have received is complete. If the consignment is
incomplete, contact your supplier or your local Siemens office.
Validity of this documentation
These operating instructions are valid for the following products:
1
● CP 5613 A2
order number: 6GK1 561-3AA01
● CP 5614 A2
order number: 6GK1 561-4AA01
Content of this documentation
These operating instructions contain information about the installation and configuration of
the CP 5613 A2 and CP 5614 A2 communications processors.
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support pages
under the following entry ID: 62612014
(http://support.automation.siemens.
Further documentation
The documents listed below contain more detailed information on commissioning and using
the communications processor. You will find this documentation on the Product Support
pages on the Internet under the following entry link:
Support (http://support.automation.siemens.com/WW/view/en
com/WW/view/en/62612014)
)
Enter the entry ID shown below of the relevant manual as the search item.
The system manuals introduce the topic of industrial communication and explain the
communications protocols used. There is also a description of the OPC interface as
user programming interface.
● Installation manual SIMATIC NET PC Software
This document contains detailed information on installing the SIMATIC NET
You will find the entire SIMATIC NET documentation on the pages of Product Support:
10805878 (http://support.automation.siemens.
Go to the required product group and make the following settings:
→ Entry list → Entry type "Manuals / Operating Instructions"
Service & Support
In addition to the product documentation, the comprehensive online information platform of
Siemens Automation Customer Support supports at any time and at any location in the
world. You will find the Service & Support pages on the Internet at the following address:
SITRAIN - Siemens training for automation and industrial solutions
With over 300 different courses, SITRAIN covers the entire Siemens product and system
spectrum in the field of automation and drive technology. Apart from the classic range of
courses, we also offer training tailored for individual needs and a combination of different
teaching media and sequences, for example self-learning programs on CD-ROM or on the
Internet.
You will find detailed information on the training curriculum and how to contact our customer
consultants at the following Internet address:
(www.siemens.com/sitrain
)
SIMATIC NET glossary
Explanations of the specialist terms used in this documentation can be found in the SIMATIC
NET glossary.
The CP 5613 A2 is a communications processor for connecting PCs to PROFIBUS. The
essential characteristics are as follows:
● The CP 5613 A2 is equipped with a PROFIBUS interface allowing up to 12 Mbps. It is
intended for operation in PGs and PCs with a PCI bus interface according to the PCI
standard V2.2.
● With the CP 5613 A2, up to 32 devices (PC, PG, SIMATIC S7 or ET 200) can be linked to
form a network segment. By linking several segments with repeaters, a maximum of 64
nodes can be connected.
● Optimized for fast DP master operation (DP Base) with up to 124 DP slaves with full data
consistency
● As an alternative, can also be used as a DP slave
● Relieves the PC due to event mechanisms (automatic detection of data changes)
2
● Fast logic support regardless of the user program (automatic linking of input and output
data can be set by the user program).
● Plug and play support during installation of the hardware
● Support of all data transmission speeds from 9.6 kbps to 12 Mbps
● Floating RS-485 connector