indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Note the following:
for the specific
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
10/2018 Subject to change
Preface
Purpose of the operating instructions
Basic knowledge required
Range of validity of these operating instructions
History
Version
Comments
These operating instructions contain all the information you need for the installation,
electrical connection, commissioning, expansion of the SIMATIC IPC847E and to maintain
and repair the device. They are intended for the following qualified specialist personnel:
● Installation personnel
● Commissioning engineers
● IT administrators
● Service and maintenance personnel
A solid background in electrical installation, personal computers, Microsoft operating
systems and network technology is required to understand this manual. General knowledge
in the field automation control engineering is recommended.
These operating instructions are valid for all supplied versions of the SIMATIC IPC847E.
Currently released versions of these operating instructions:
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens' products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be
connected to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or network
segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit (http://www.siemens.com/industrialsecurity).
Siemens' products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers' exposure
to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (http://www.siemens.com/industrialsecurity).
This product includes third-party software. Siemens AG only provides a warranty for
updates/patches of the third-party software, if these have been distributed as part of a
Siemens software update service contract or officially released by Siemens AG. Otherwise,
updates/patches are undertaken at your own risk. You can find more information about our
Software Update Service offer on the Internet at Software Update Service
(http://www.automation.siemens.com/mcms/automation-software/en/software-update-
10 Standards and approvals ....................................................................................................................... 167
A Hardware description ............................................................................................................................. 171
9.1 Dimension drawing of the device .......................................................................................... 163
9.2 Dimension drawing of the Tower Kit ..................................................................................... 164
9.3 Dimension drawing of the expansion cards .......................................................................... 165
9.4 Dimension drawing of the telescope rails ............................................................................. 166
10.1 CE marking ........................................................................................................................... 167
10.2 DIN ISO 9001 certificate and software license agreements ................................................. 168
10.3 UL approval ........................................................................................................................... 168
B Technical support .................................................................................................................................. 195
C Markings and symbols ........................................................................................................................... 201
D List of abbreviations ............................................................................................................................... 205
Index ...................................................................................................................................................... 209
B.1 Service and support ............................................................................................................. 195
Depending on the configuration ordered the features and illustrations described in this
manual may differ from the features of your device.
Maximum industrial compatiblity for 24-hour continuous use in industrial environments
1.2 Product highlights
The SIMATIC IPC847E is a powerful industrial PC in 19" rack format design (4 HE). It is
perfectly suited for PC applications with high-level industry functionality.
● Maximum processor performance (in full configuration) without loss of performance
(throttling) at up to 50 °C ambient temperature
● Fully coated surfaces that repel dirt and corrosion
● Rugged all-metal housing, coated over its entire surface (blue chromated) and enameled
on the outside to protect against corrosion and dirt with high EMC compatibility
● Suitable for installation in space-saving control cabinets with a depth of only 500 mm
● Dust protection through overpressure venting concept with front-side fan and dust filter
● Protection against vibration and shock through corresponding hard drive retainer and
High system availability thanks to minimization of standstill times
Differentiated safety concepts
1.2 Product highlights
● 8th generation Intel® processors: Xeon, Core i7, Core i5 or Core i3 up to 6 cores /
12 threads
● Graphics controller (630/P630) integrated in the processor up to 4 K Ultra HD resolution
● Maximum performance, e.g. through Intel C246 chipset, DDR4 memory with support of
dual channel technology
● High data transfer rates, e.g. via PCI Express Technology Gen 3,
USB 3.1 Gen 2 SuperSpeed + (10 Gbps), M.2 NVME SSD
● Low noise level due to variable-speed fans
● High data security through RAID systems: Onboard RAID system or hardware RAID
system
● RAID1 system: Data mirroring onto two SATA or SAS drives, including in removable drive
bays, and optionally with additional SDD (for operating system) or hot-spare drive
● RAID5 system: Striping with parity onto three SATA or SAS drives for increased memory
capacity in removable drive bays, optionally with additional hot-spare drive
● Hot swap (swapping of drive during operation) in removable drive bays in RAID systems
● Hot-spare drive in removable drive bays in RAID systems: The rebuild process onto the
hot-spare drive starts automatically
● Fast identification and swapping of drives under error conditions through alarm LEDs for
RAID systems
● Efficient event diagnostics through the SIMATIC IPC DiagBase or DiagMonitor monitoring
software (optional)
● Remote control and remote maintenance of the device through iAMT (Intel® Active
Management Technology)
● SSD as 2.5" SATA or M.2 NVMe and ECC memory (optional)
● Replacement of the redundant power supply module during operation
● Lockable front door for component protection against unauthorized access, e.g.
– Software dongle in USB connection behind the front door
– Front fan can only be replaced when front door is open
– All components inside the device can only be accessed when front door is open
● Device monitoring through operating displays on the front for Ethernet; alarms for fan,
temperature, watchdog and drives in RAID1 or RAID5 systems
SIMATIC IPC847E
14Operating Instructions, 10/2018, A5E43920357-AA
Product description
High investment protection
User-friendly application scenarios for commissioning, use and service
1.3
Scope of application
1.3 Scope of application
● Platform with embedded Intel components for long-term stability
● Availability: 3 to 6 years
● Assured spare parts availability: 5 years after product expiry
● Certified for worldwide marketing (cULus)
● Support of legacy interfaces (COM)
● Compatible installation across device generations
● Worldwide service and support
● High flexibility and expandability through integrated interfaces and up to 11 slots (PCI and
PCI Express)
● Pre-installed and activated operating system
● Fast restoration of delivery state of the operating system (with supplied data storage
medium)
● Universal use as industrial workstation or industrial server
● Gbit LAN with teaming capability (3 x LAN 10/100/1000 Mbps connections)
● Service-friendly device configuration (modifications, service), e.g. replacement of filter or
front fan without tools
● Can be used flexibly in different positions with telescopic guide support or as an industrial
tower PC
The SIMATIC IPC offers system integrators, cabinet designers, system engineers and
machine designers a 19" rack PC platform for high-performance applications and IT
applications on the control and cell level for:
● Process and visualization applications
● Industrial image processing
● Quality assurance and monitoring tasks
● Measurement, control and rule-based tasks
● Data acquisition and management
The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential
and commercial areas and small businesses. In addition to the industrial applications,
therefore, it can also be used in building automation or in public facilities.
The On/off button ① and the reset button ② are located on the front of the device behind
the front door. The On/off button starts and shuts down the operating system. The reset
button is for the emergency when the device can no longer be operated.
Additional information is available in "Switching on the device (Page 59)" and "Switching off
the device (Page 60)".
The alarm reset button is only available for devices with redundant power supply.
Use the alarm reset button to switch off the signal tone of the redundant power supply in the
event of an error.
SIMATIC IPC847E
24Operating Instructions, 10/2018, A5E43920357-AA
Product description
1.4.7
Status displays
1.4.7.1
System status displays
Item
Status display
Meaning
Color
Description
OFF
Switched off or disconnected from the mains
YELLOW
Idle state or shut down
GREEN
PC in operation
OFF
No access
GREEN
Access
③
⑤
OFF
Not activated
GREEN
Activated
RED
Expired
⑦
OFF
No error
⑧
OFF
No error
1.4 External design of the device
The status displays for the system are located on the front of the device. They provide
information on the status of the device components.
HDD alarm in combination with RAID and
monitoring software.
The number of the HDD
alarm corresponds to
the number of mounting
locations of drives, see
"Drive cage type A
(Page 17)" and "Drive
cage type B (Page 18)".
A RED LED is lit up The associated drive is not OK
All RED LEDs are
flashing
All RED LEDs are lit
up
RAID synchronization running, RAID is not
OK
The hard disk newly integrated in case of
error is synchronized with an existing hard
RAID is not OK
The faulty drive could not be localized by the
monitoring software. It may be possible to
detect the defective drive with the RAID software.
Information is available at "RAID1 system
(Page 65)", "RAID5 system (Page 65)" or
"Hot-spare drive in RAID1 or RAID5 systems
SIMATIC IPC847E
26Operating Instructions, 10/2018, A5E43920357-AA
Product description
1.4.7.2
Status display of the Ethernet interface
Status display
Meaning
Status
Meaning of the status
1.4 External design of the device
The Ethernet interfaces are numbered on the enclosure to identify them clearly.
The numbering by the operating system can differ.
Obtaining accessories from the SIEMENS Industry Mall
Accessories available for order
Name
Description
Article number
1.6 Accessories and spare parts
Accessories from Siemens are available for your device. These are not included in the scope
of delivery.
You can find additional information in the online ordering system Industry Mall
(https://mall.industry.siemens.com).
Retainer for
locking the internal USB interface
Tower Kit
for
SIMATIC IPCs
The retainer is a mechanical safety device
for the internal USB interface. It optimizes
the protection of an internal USB memory
stick against loads caused by vibration and
shock during transportation or operation.
This increases the reliability and operational
safety of the device.
You can use the Tower Kit to convert the
device into an industrial Tower PC. This step
expands the operating range beyond the
control cabinet.
Components of the Tower Kit:
• Cover
• Feet
• Accessories: Screws and rubber feet
6ES7648-1AA00-0XK0
6ES7648-1AA01-0XC0
SIMATIC IPC847E
30Operating Instructions, 10/2018, A5E43920357-AA
Loading...
+ 182 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.