indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Note the following:
for the specific
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
12/2016 Subject to change
Preface
Basic knowledge required
Scope of validity of this documentation
Scope of this documentation
Conventions
These operating instructions contain all the information you need for commissioning and
operation of the SIMATIC IPC277D.
It is intended both for programming and testing personnel who commission the device and
connect it with other units (automation systems, programming devices), as well as for service
and maintenance personnel who install add-ons or carry out fault/error analyses.
A solid background in personal computers and Microsoft operating systems is required to
understand this manual. General knowledge in the field automation control engineering is
recommended.
These operating instructions are valid for all versions of the SIMATIC IPC277D.
The documentation for the SIMATIC IPC277D consists of:
● Product information, e.g. "Important notes on your device"
● Quick Install Guide SIMATIC IPC277D
● SIMATIC IPC277D operating instructions in English and German
The PDF version of the documentation is supplied with the device on the
"Documentation and Drivers" CD/DVD.
The terms "PC" or "device" are used in place of the product name SIMATIC IPC277D in
these operating instructions.
In these operating instructions, the terms "Windows Embedded Standard 2009" and
"Windows Embedded Standard 7" are also abbreviated with the term "Windows Embedded
Standard". "Windows 7" is used as an abbreviation for "Windows 7 Ultimate".
The following earlier release versions of these operating instructions have been published:
11/2011 Second edition, valid for all delivery stages
Preface Purpose, layout and description of the important topics
Table of contents Detailed organization of the documentation, including the index of pages
Overview
Safety instructions All generally valid safety aspects:
Installing and connecting the device
Commissioning the
Extended device func-
• Description of the product: Characteristics and field of application
• Product package
• Structure of the product/system: Operator control and connection ele-
ments
• Accessories
• Legal requirements
• Product/system view during installation
• General information on commissioning
• Notes on operation
• Application planning: Aspects of storage, transport, environmental and
EMC conditions to be considered in the preparatory stage.
• Installation: Product installation options and installation instructions
• Connection: Options of connecting the product and wiring instructions
• Integration: Options of integrating the product into existing or planned
automation systems and networks.
Commissioning the product/system
Monitoring and display functions
Expanding and assigning parameters to the
SIMATIC IPC277D
4Operating Instructions, 12/2016, A5E03409486-AE
Procedure for installing device expansions (modules, drives)
Preface
Content structure
Contents
Abbreviations
Abbreviations of the technical terms used
Device maintenance
and repair
Technical specifications
Technical support
• Replacing hardware components
• Restoring and setting up the operating system and BIOS (Recovery)
• Installing drivers and software
• Service and spare parts
• Recycling and disposal
• General specifications in compliance with relevant standards and cur-
rent/voltage values
• Guidelines and certifications, ESD guidelines, notes on retrofitting
• Dimension drawings: Dimensions of the device and of modules
• Detailed descriptions of boards and system resources
A Technical Support .................................................................................................................................. 161
B Markings and symbols ........................................................................................................................... 163
C List of abbreviations ............................................................................................................................... 167
Index ...................................................................................................................................................... 179
The SIMATIC IPC277D provides high-level industrial performance.
● Compact design
● Rugged
● Maintenance-free operation possible
SIMATIC IPC277D is available with various control units that differ with regard to the display
size. This display is a color display with a backlit "wide-screen" format TFT color display.
Displays are available in the following sizes for the SIMATIC IPC277D:
This section describes the 12", 15" and 19" devices using the example of the
SIMATIC IPC277D 12". The 15" and 19" devices have an additional USB port at the
front.
IPC277D 7" and 9" – interfaces and operator controls
①
RJ45 Ethernet connection LAN2 for 10/100/1000 Mbps
②
RJ45 Ethernet connection LAN1 for 10/100/1000 Mbps
③
RS-232 interface, D-sub connector, 9-pin
④
Only two USB interfaces may be operated simultaneously in high-current mode.
⑤
On/off switch. OFF position, when the symbol "C-" is pressed in.
⑥
Connection for a 24 VDC power supply
⑦
Protective conductor connection
1.2.5
IPC277D 12", 15" and 19" – interfaces and operator controls
①
Protective conductor connection
②
On/off switch: OFF position, when the symbol "C-" is pressed in.
③
Connection for a 24 VDC power supply
④
RJ45 Ethernet connection LAN2 for 10/100/1000 Mbps
⑤
RJ45 Ethernet connection LAN1 for 10/100/1000 Mbps
⑥
RS-232 interface, D-sub connector, 9-pin
⑦
Only two USB interfaces may be operated simultaneously in high-current mode.
1.2 Configuration of the devices
USB 2.0 connection, high speed
Observe the printing on the rear of the device.
USB 2.0 connection, high speed
Observe the printing on the rear of the device.
SIMATIC IPC277D
20Operating Instructions, 12/2016, A5E03409486-AE
Overview
1.3
Accessories
CompactFlash cards
Note
Replace CompactFlash cards only with replacement cards of the same product versions
You may only operate this device with SIMATIC PC Co
03 (ES03 or higher).
Touch pen
1.3 Accessories
This section contains the scope of accessories valid at the time these operating instructions
were written. Additional accessories can be found on the Internet at:
● Expansion components and accessories (http://www.automation.siemens.com/mcms/pc-
Life-threatening voltages are present with an open control cabinet
System expansions
NOTICE
Damage through system expansions
WARNING
Risk of fire
When you install the device in a control cabinet, some areas or components in the open
control cabinet may be carrying life-threatening voltages.
If you touch these areas or components, you may be killed by electric shock.
Switch off the power supply to the cabinet before opening it.
Device and system expansions may be faulty and can affect the entire machine or plant.
The installation of expansions can damage the device, machine or plant. Device and
system expansions may violate safety rules and regulations regarding radio interference
suppression. If you install or exchange system expansions and damage your device, the
warranty becomes void.
Note the following for system expansions:
• Only install system expansion devices designed for this device. Contact your technical
support team or where you purchased your PC to find out which system expansion
devices may safely be installed.
• Observe the information on electromagnetic compatibility (Page 112).
The device is classified as "Open Type" for use in the area of industrial control equipment
in accordance with UL508. Burning substances may escape and cause fire in the event of
overheating.
Please therefore note the following:
• The installation of the device in an enclosure conforming to UL508 is a mandatory
requirement for approval and operation in accordance with UL508.
• Install the device in an enclosure that meets the requirements of paragraphs 4.6 and
4.7.3 of the standards EN 60950-1:2006 and IEC/UL/EN/DIN-EN 60950-1.
Risk of explosion and release of harmful substances
High frequency radiation
NOTICE
Unintentional operating situations
2.1 General safety instructions
Improper handling of lithium batteries can result in an explosion of the batteries.
Explosion of the batteries and the released pollutants can cause severe physical injury.
Worn batteries jeopardize the function of the device.
Note the following when handling lithium batteries:
• Replace used batteries in good time; see the section "Replacing the backup battery" in
the operating instructions.
• Replace the lithium battery only with an identical battery or types recommended by the
manufacturer (order no.: A5E30314053).
• Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge,
do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C, and
protect from direct sunlight, moisture and condensation.
High frequency radiation, e g. from a cellular phone, interferes with device functions and
can result in malfunctioning of the device.
Persons are injured and the plant is damaged.
Avoid high-frequency radiation:
• Remove radiation sources from the environment of the device.
• Switch off radiating devices.
• Reduce the radio output of radiating devices.
• Observe the information on electromagnetic compatibility (Page 112).
SIMATIC IPC277D
24Operating Instructions, 12/2016, A5E03409486-AE
Safety instructions
ESD Guideline
NOTICE
Electrostatic sensitive devices (ESD)
through voltages
Industrial Security
Disclaimer for third-party software updates
2.1 General safety instructions
Electrostatic sensitive devices can be labeled with an appropriate symbol.
When you touch electrostatic sensitive components, you can destroy them
that are far below the human perception threshold.
If you work with components that can be destroyed by electrostatic discharge, observe the
ESD Guideline (Page 112).
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines
and networks. Systems, machines and components should only be connected to the
enterprise network or the internet if and to the extent necessary and with appropriate security
measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit
(http://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends to apply product updates as soon as available and to
always use the latest product versions. Use of product versions that are no longer supported,
and failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (http://www.siemens.de/automation/csi_en_WW).
This product includes third-party software. Siemens AG only provides a warranty for
updates/patches of the third-party software, if these have been distributed as part of a
Siemens software update service contract or officially released by Siemens AG. Otherwise,
updates/patches are undertaken at your own risk. You can find more information about our
Software Update Service offer on the Internet at Software Update Service
(http://www.automation.siemens.com/mcms/automation-software/en/software-update-
A user with administrator privileges has extensive access and manipulation options in the
system.
Therefore, ensure there are adequate safeguards for protecting the administrator accounts
to prevent unauthorized changes. To do this, use secure passwords and a standard user
account for normal operation. Other measures, such as the use of security policies, should
be applied as needed.
SIMATIC IPC277D
26Operating Instructions, 12/2016, A5E03409486-AE
Safety instructions
2.2
Notes on usage
WARNING
Risks associated with the unprotected machine or plant
Environment
NOTICE
Ambient conditions and chemical resistance
Without additional safety measures, such as a supply of clean air, the device may not be
2.2 Notes on usage
According to the results of a risk analysis, certain hazard potentials associated with the
unprotected machine exist. These hazards could lead to personal injury.
Avoid such hazards by taking the following precautions in accordance with the risk analysis:
• Installation of additional safety equipment on the machine or plant. In particular, the
programming, parameter assignment and wiring of the inserted I/O modules must be
executed in accordance with the safety performance identified by the necessary risk
analysis (SIL, PL or Cat.).
• Use as intended must be validated for the device by means of a function test on the
plant. These tests help you to identify programming, parameter assignment and wiring
errors.
• Documentation of the test results that you can enter in the relevant safety verification
documents, if necessary.
Unsuitable environmental conditions have a negative impact on device operation. Chemical
substances such as cleaners or fuels may alter the color, shape and structure of the device
surface, for example, the front panel.
The device may be damaged. possibly resulting in malfunctions.
For this reason, please observe the following precautions:
• Always operate the device in closed rooms. All warranties shall be void in the case of
noncompliance.
• Operate the device only in accordance with the ambient conditions specified in the
technical specifications.
• Protect the device against dust, moisture and heat.
• Do not expose the device to direct sunlight or to other strong sources of light.
•
used in locations with harsh operating conditions caused by acidic vapors or gases.
• Always use suitable cleaning agents. Read the information on the Internet concerning
chemical resistance, see the "After Sales Information System for SIMATIC PC/PG"
(http://www.siemens.com/asis) link in the chapter "Technical Support" in section service
and support (Page 161).
Note
Use in an industrial environment without additional protective measures
The device has been designed for use in a normal industrial environment in accordance with
IEC
TFT displays
NOTICE
Burn-in effect and backlighting
eensaver. The backlight brightness is reduced while the screensaver is
Defective pixels in the display
2.2 Notes on usage
60721-3-3 (pollutant class 3C2 for chemical influences, 3S2 for sand and dust).
A permanent picture with bright screen objects leads to a burn-in effect. The longer the
same screen contents are displayed, the longer it will take for the burn-in effect to
disappear. Screensavers (for example, "starfield simulation") for the backlit active black
mode reduce the burn-in effect. The brightness of the backlighting deteriorates over the
course of the screen's life cycle.
The service life of the screen and backlighting is extended by the following measures:
• Switch on the scr
active.
• You should also reduce the backlighting.
• Observe the backlighting operating time.
At present, the manufacturing process of modern displays does not guarantee that all pixels
of the display will be perfect. A small number of defective pixels in the display is therefore
unavoidable. This does not present a functional problem as long as the defective pixels are
not bunched in one location.
Additional information is available in the section "General technical specifications
(Page 120)".
SIMATIC IPC277D
28Operating Instructions, 12/2016, A5E03409486-AE
3
3.1
Preparing for installation
3.1.1
Checking the delivery package
Procedure
Note
Damage to the device during transport and storage
If a device is transported or stored without packaging, shocks, vibrations, pressure and
moisture may impact the unprotected unit. A damaged pack
conditions have already had a massive impact on the device.
The device may be damaged.
Do not dispose of the original packaging. Pack the device during transportation and
storage.
1. When accepting a delivery, please check the packaging for visible transport damage.
2. If any transport damage is present at the time of delivery, lodge a complaint at the
shipping company in charge. Have the shipper confirm the transport damage
immediately.
3. Unpack the device at its installation location.
4. Keep the original packaging in case you have to transport the unit again.
aging indicates that ambient
5. Check the contents of the packaging and any accessories you may have ordered for
completeness and damage.
Electric shock and fire hazard due to damaged device
NOTICE
Damage from condensation
3.1 Preparing for installation
6. If the contents of the packaging are incomplete, damaged or do not match your order,
inform the responsible delivery service immediately. Fax the enclosed form
"SIMATIC IPC/PG Quality Control Report".
A damaged device can be under hazardous voltage and trigger a fire in the machine or
plant. A damaged device has unpredictable properties and states.
Death or serious injury could occur.
Make sure that the damaged device is not inadvertently installed and put into operation.
Label the damaged device and keep it locked away. Send off the device for immediate
repair.
If the device is subjected to low temperatures or extreme fluctuations in temperature
during transportation, for example in cold weather, moisture could build up on or inside
the HMI device.
Moisture can result in short-circuits in electrical circuits and damage the device.
In order to prevent damage to the device, proceed as follows:
• Store the device in a dry place.
• Bring the device to room temperature before starting it up.
• Do not expose the device to direct heat radiation from a heating device.
• If condensation develops, wait approximately 12 hours or until the device is
completely dry before switching it on.
7. Please keep the enclosed documentation in a safe place. It belongs to the device. You
the documentation when you commission the device for the first time.
need
8. Write down the identification data of the device.