indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
for the specific
05/2018 Subject to change
Preface
Basic knowledge requirements
Introduction
Scope of this documentation
Conventions
Generic term
Specific name
Device
IOT2000 Extension Modules
Figures
These operating instructions contain all the information you need for commissioning and
operation of the IOT2000 Extension Modules. It is intended both for programming and testing
personnel who commission the device and connect it with other units (automation systems,
programming devices), as well as for service and maintenance personnel who install addons or carry out fault/error analyses.
Knowledge of personal computers, operating systems and programming is required to
understand this manual. General knowledge in the field automation control engineering is
recommended.
This operating instruction applies to the following devices:
● IOT2000 Input/Output Module
● IOT2000 Input Module Sink/Source
The device documentation comprises:
● SIMATIC IOT2000 Extension Modules Operating Instructions in English, Chinese and
German
The following generic terms are used in this documentation:
This manual contains figures of the described devices. The supplied device may differ in
some details from the figures. Within some of the figures, one device is used to represent all
devices.
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
3
Preface
History
Edition
Comment
02/2017
First edition
The following editions of these operating instructions have been published:
4.2.3.1 Hardware Interface for IOT2000 Input/Out Module ............................................................. 30
4.2.3.2 Hardware Interface for IOT2000 Input Module Sink/Source ................................................ 31
5.1 Service and support........................................................................................................... 33
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
5
Table of contents
IOT2000 Extension Modules
6Operating Instructions, 2018/05, A5E39456816-AB
1
1.1
Product description
Features for devices
IOT2000 Extension Modules provide IOT2000 system with a variety of standard industrial
input/output interface, which can provide customers with more applications.
Although the IOT2000 Extension Modules have an ARDUINO UNO R3 compatible interface,
we designed and tested for use with IOT2020 and IOT2040.
● Work both for IOT2020 and IOT2040
● Depending on the industrial area of application.
– IOT2000 Input/Output Module: has five digital inputs, two analog inputs and two digital
outputs.
– IOT2000 Input Module Sink/Source: only has ten digital inputs.
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
7
Overview
1.2
Structure of the devices
1.2.1
Structure of SIMATIC IOT2000 Input/Output Module
IOT2000 Input/Output Module
Interface
Interface description
①
M 1)
Ground of analog input
U0, U1
Analog voltage input
I0, I1
Analog current input
②
M1 2)
Ground of digital output
L+
Power supply of digital output
DQ0, DQ1
Digital output
M0 2)
Ground of digital input
1)
M is directly connected with the M of Arduino interface and it is not isolated.
2)
M0 and M1 are isolated by optical coupling.
1.2 Structure of the devices
The following figure shows the configuration and interfaces of the IOT2000 Input/Output
Module.
Analog interface
Digital output interface
Digital input interface
③
DI1 DI2, DI3, DI4, DI5 Digital input
IOT2000 Input/Output Module cover
④
For more information on configuration and interfaces of the SIMATIC IOT2000, see
IOT2020, SIMATIC IOT2040 Operating Instructions.
SIMATIC
IOT2000 Extension Modules
8Operating Instructions, 2018/05, A5E39456816-AB
Overview
1.2.2
Structure of SIMATIC IOT2000 Input Module Sink/Source
IOT2000 Input Module Sink/Source
Interface
Interface description
M0-M9 1)
Ground of digital input
②
1)
M0, M1 to M9 are all isolated by optical coupling.
1.2 Structure of the devices
The following figure shows the configuration and interfaces of the IOT2000 Input Module
Sink/Source.
Digital input interface
①
DI0-DI9 Digital input
IOT2000 Input Module Sink/Source cover
For more information on configuration and interfaces of the SIMATIC IOT2000, see
IOT2020, SIMATIC IOT2040 Operating Instructions.
SIMATIC
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
9
Overview
1.2 Structure of the devices
IOT2000 Extension Modules
10Operating Instructions, 2018/05, A5E39456816-AB
2
2.1
Industrial security
Industrial Security
2.2
General safety instructions
Strong high-frequency radiation
NOTICE
Observe immunity to RF radiation
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines
and networks. Systems, machines and components should only be connected to the
enterprise network or the internet if and to the extent necessary and with appropriate security
measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit
(https://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends to apply product updates as soon as available and to
always use the latest product versions. Use of product versions that are no longer supported,
and failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (https://www.siemens.com/industrialsecurity).
The device has an increased immunity to RF radiation according to the specifications on
electromagnetic compatibility in the technical specifications.
Radiation exposure in excess of the specified immunity limits can impair device functions,
result in malfunctions and therefore injuries or damages.
Read the information on immunity to RF radiation in the technical specifications.
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
11