Industrial Ethernet switches
SCALANCE XB-000
Description of the device
Maintenance and
troubleshooting

Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜ
11/2015 Subject to change
Copyright © Siemens AG 2009 - 2015.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
indicates that death or severe personal injury will result if proper precautions are not taken.
indicates that death or severe personal injury may result if proper precautions are not taken.
indicates that minor personal injury can result if proper precautions are not taken.
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance a
re required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
3
1 Introduction ............................................................................................................................................. 5
1.1 On the Operating Instructions ................................................................................................... 5
1.2 On the product .......................................................................................................................... 7
2 Network topologies ............................................................................................................................... 11
3 Description of the device ....................................................................................................................... 13
3.1 SCALANCE XB-000 overview ................................................................................................ 13
3.2 Product characteristics............................................................................................................ 15
3.2.1 SCALANCE XB004-1.............................................................................................................. 15
3.2.2 SCALANCE XB004-2.............................................................................................................. 16
3.2.3 SCALANCE XB004-1LD ......................................................................................................... 17
3.2.4 SCALANCE XB005 ................................................................................................................. 18
3.2.5 SCALANCE XB008 ................................................................................................................. 19
3.2.6 SCALANCE XB004-1G ........................................................................................................... 20
3.2.7 SCALANCE XB004-1LDG ...................................................................................................... 21
3.2.8 SCALANCE XB005G .............................................................................................................. 22
3.2.9 SCALANCE XB008G .............................................................................................................. 23
3.3 TP ports (twisted pair) ............................................................................................................. 24
3.3.1 Pin assignment ....................................................................................................................... 24
3.3.2 Functions ................................................................................................................................ 25
3.3.3 Insulation between the TP ports ............................................................................................. 26
3.4 FO port (fiber optic) ................................................................................................................. 28
3.4.1 SCALANCE XB004-1.............................................................................................................. 28
3.4.2 SCALANCE XB004-2.............................................................................................................. 29
3.4.3 SCALANCE XB004-1LD ......................................................................................................... 30
3.4.4 SCALANCE XB004-1G ........................................................................................................... 31
3.4.5 SCALANCE XB004-1LDG ...................................................................................................... 32
3.5 LEDs ....................................................................................................................................... 33
4 Mounting ............................................................................................................................................... 35
4.1 Safety notices for installation .................................................................................................. 35
4.2 Types of installation ................................................................................................................ 36
4.3 Fixing onto standard mounting rails ........................................................................................ 37
4.4 Wall mounting ......................................................................................................................... 39
5 Connecting up ....................................................................................................................................... 41
5.1 Power supply .......................................................................................................................... 41
5.1.1 Power supply 24 VAC ............................................................................................................. 41
5.1.2 Power supply 24 VDC ............................................................................................................. 42

Table of contents
SCALANCE XB-000
4 Operating Instructions, 12/2015, A2B00077300-06
5.2 Grounding .............................................................................................................................. 43
5.3 Twisted pair cable .................................................................................................................. 44
5.4 IE FC RJ-45 Plug 180 ............................................................................................................ 44
6 Maintenance and troubleshooting .......................................................................................................... 47
6.1 Possible sources of problems and how to deal with them ..................................................... 47
7 Technical specifications ........................................................................................................................ 49
7.1 SCALANCE XB004-1 ............................................................................................................. 49
7.2 SCALANCE XB004-2 ............................................................................................................. 52
7.3 SCALANCE XB004-1LD ........................................................................................................ 54
7.4 SCALANCE XB005 ................................................................................................................ 57
7.5 SCALANCE XB008 ................................................................................................................ 59
7.6 SCALANCE XB004-1G .......................................................................................................... 61
7.7 SCALANCE XB004-1LDG ..................................................................................................... 63
7.8 SCALANCE XB005G ............................................................................................................. 65
7.9 SCALANCE XB008G ............................................................................................................. 67
8 Approvals ............................................................................................................................................. 69
9 Dimension drawings .............................................................................................................................. 73
Index .................................................................................................................................................... 75

SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
5
On the Operating Instructions
Purpose of the Operating Instructions
These Operating Instructions support you when commissioning networks with the Industrial
Ethernet switches of the SCALANCE XB-000 product line.
Validity of the Operating Instructions
These operating instructions are valid for the following devices:
XB004-1 6GK5 004-1BD00-1AB2
The "SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks" manual
contains additional information on other SIMATIC NET products that you can operate along
with the IE switches of the SCALANCE XB-000 product line in an Industrial Ethernet
network.
You can order the manual "SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks",
release 05/2001, using the following order numbers:
6GK1970-1BA10-0AA0 German
6GK1970-1BA10-0AA1 English
6GK1970-1BA10-0AA2 French
6GK1970-1BA10-0AA4 Italian
You will also find this network manual on the Internet pages of Service & Support under the
following entry ID: 1172207 (http://support.automation.siemens.com/WW/view/en/1172207
).
You will find further information in the "System Manual Industrial Ethernet" in the Manual
Collection.
You will find further information on the SCALANCE system on the Internet at
www.siemens.com/scalance (www.siemens.com/scalance
).

Introduction
1.1 On the Operating Instructions
SCALANCE XB-000
6 Operating Instructions, 12/2015, A2B00077300-06
These Operating Instructions are intended for persons who commission networks with the IE
switches of the SCALANCE XB-000 product line.
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary here:
● SIMATIC NET Manual Collection or product DVD
The DVD ships with certain SIMATIC NET products.
● On the Internet under the following address:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045
)
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, solutions, machines, equipment and/or networks. They are
important components in a holistic industrial security concept. With this in mind, Siemens’
products and solutions undergo continuous development. Siemens recommends strongly
that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept) and integrate each component into a holistic,
state-of-the-art industrial security concept. Third-party products that may be in use should
also be considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity
.
To stay informed about product updates as they occur, sign up for a product-specific
newsletter. For more information, visit http://support.automation.siemens.com
.

Introduction
1.2 On the product
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
7
On the product
What is possible?
The IE switches of the SCALANCE XB-000 product line allow the cost-effective installation of
Industrial Ethernet bus and star structures with switching functionality.
With the following IE switches, there are also electrical/optical media transitions:
● SCALANCE XB004-1
● SCALANCE XB004-2
● SCALANCE XB004-1LD
● SCALANCE XB004-1G
● SCALANCE XB004-1LDG
Note
It is not possible to use IE switches of the SCALANCE
XB-000 product line in a redundant
ring because they do not support redundancy.
Note
If devices are supplied over long 24 V power supply lines or networks, measures are
necessary to prevent interference by strong electromagnetic pulses on the supply lines.
These can result, for example, due to lightning or switching of large inductive load
One of the tests used to attest the immunity of these devices to electromagnetic interference
is the "surge immunity test" according to EN 61000
-4-5. This test requires overvoltage
protection for the power supply lines. A suitable device is, for exampl
BVT AVD 24 V type no. 918 422 or a comparable protective element. For AC operation, for
example the blitzductor BVT ALD 60 Art. no. 918409 or a comparable protective element is
suitable.
Manufacturer:
DEHN+SÖHNE GmbH+Co.KG Hans Dehn
Str.1 Postfach 1640 D-92306 Neumarkt,
Components of the product
The following components are supplied with a SCALANCE XB-000:
● IE switch SCALANCE XB-000
● 3-pin terminal block (power supply)
● Product information

Introduction
1.2 On the product
SCALANCE XB-000
8 Operating Instructions, 12/2015, A2B00077300-06
Suitable for
XB-000
Fast Ethernet
Suitable for
XB-000G
Gigabit Ethernet
IE TP Cord RJ-45/RJ-45, CAT 6,
TP cable 4x2, fitted with 2 RJ-45
0.5 m 1 6XV1870-3QE50 + +
IE TP Cord RJ-45/RJ-45, CAT 6,
TP cable 4x2, fitted with 2 RJ-45
plugs
1 m 1 6XV1870-3QH10 + +
IE TP Cord RJ-45/RJ-45, CAT 6,
TP cable 4x2, fitted with 2 RJ-45
2 m 1 6XV1870-3QH20 + +
IE TP Cord RJ-45/RJ-45, CAT 6,
TP cable 4x2, fitted with 2 RJ-45
6 m 1 6XV1870-3QH60 + +
IE TP Cord RJ-45/RJ-45, CAT 6,
TP cable 4x2, fitted with 2 RJ-45
IE FC blade cassettes (5 mm)
IE FC TP standard cable GP 2x2
IE FC TP standard cable GP 4x2
IE FC TP trailing cable GP
IE FC TP flexible cable GP 2x2 - 1 6XV1870-2B + -
IE FC TP flexible cable GP 4x2
IE FC TP FRNC cable GP - 1 6XV1871-2F + -
IE FC TP festoon cable GP
FO standard cable 50/125, fitted
with 2x2 SC connectors, pulling aid
80 m 1 6XV1873-6AN80 + +
FO standard cable 50/125, fitted
with 2x2 SC connectors, pulling aid
100 m 1 6XV1873-6AT10 + +
FO standard cable 50/125, fitted
with 2x2 SC connectors, pulling aid
150 m 1 6XV1873-6AT15 + +
FO standard cable 50/125, fitted
with 2x2 SC connectors, pulling aid
200 m 1 6XV1873-6AT20 + +
FO standard cable 50/125, fitted
with 2x2 SC connectors, pulling aid
300 m 1 6XV1873-6AT30 + +
FO standard cable GP (50/125)
FO trailing cable (50/125)
FO trailing cable GP (50/125)

Introduction
1.2 On the product
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
9
Suitable for
XB-000
Fast Ethernet
Suitable for
XB-000G
Gigabit Ethernet
IE FC RJ-45 Plug 180 2x2 - 1 6GK1901-1BB10-2AA0 + -
Note
For the devices with Fast Ethernet, you can use cables and connectors with 2x2 lines. The
use of 4x2 lines is also possible but not absolutely necessary. These products are indicated
by (+).
Do not use any parts that show evidence of damage
If you use damaged parts, there is no guarantee that the device will function according to
the specification.
If you use damaged parts, this can lead to the following problems:
• Injury to persons
• Loss of the approvals
• Violation of the EMC regulations
• Damage to the device and other components
Use only undamaged parts.
1. Make sure that the package is complete.
2. Check all the parts for transport damage.

Introduction
1.2 On the product
SCALANCE XB-000
10 Operating Instructions, 12/2015, A2B00077300-06
Electrostatic sensitive devices (ESD)
Electronic modules contain electrostatic sensitive components
These components can easily be destroyed if handled incorrectly.
Note the following instructions to avoid damage.
• Touch electronic modules only when you absolutely need to work on them.
• If electronic modules need to be touched, the body of the person involved must first be
electrostatically discharged and grounded.
• Do not bring electronic modules in contact with electrically isolating materials such as
plastic film, isolating table top pads or clothing made of synthetic fibers.
• Place the modules only on conductive surfaces.
• Pack, store and transport electronic modules and components only in conductive
packaging such as metalized plastic or metal containers, conductive foam or household
aluminum foil.

SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
11
Switching technology allows extensive networks to be set up with numerous nodes and
simplifies network expansion.
Which topologies can be implemented?
Using the IE switches of the SCALANCE XB-000 product line, you can implement star
topologies.
Note
Keep to the maximum permitted cable lengths of the devices you are using. You will find the
permitted cable lengths in the section "
Technical specifications (Page 49)".
Figure 2-1 Example of an electrical star topology with SCALANCE XB005

Network topologies
SCALANCE XB-000
12 Operating Instructions, 12/2015, A2B00077300-06
Figure 2-2 Example of an electrical/optical star topology with SCALANCE XB004-1

SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
13
Table 3- 1 Overview of the product characteristics
Signaling contact
+ on-site opera-
- - - - - - - - -
Diagnostics:
Web, SNMP,
- - - - - - - - -
Passive ring
- - - - - - - - -
Standby redun-
Passive listening - - - - - - - - -
1)
Note the Hardware version (Page 49).

Description of the device
3.1 SCALANCE XB-000 overview
SCALANCE XB-000
14 Operating Instructions, 12/2015, A2B00077300-06
Table 3- 2 Overview of the connection options
TP (RJ-45)
Fast Ethernet 10
4 4 4 5 8 - - - -
Fiber multimode
(SC)
Fast Ethernet
1 2 0 - - - - - -
Single-mode fiber
(SC)
Fast Ethernet
0 0 1 - - - - - -
TP (RJ-45)
Gigabit Ethernet
10 / 100 / 1000
- - - - - 4 4 5 8
Fiber multimode
(SC)
Gigabit Ethernet
- - - - - 1 0 - -
Fiber single
mode (SC)
Gigabit Ethernet

Description of the device
3.2 Product characteristics
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
15
Product characteristics
3.2.1
SCALANCE XB004-1
Possible attachments
The SCALANCE XB004-1 has four RJ-45 jacks and an SC socket for the connection of end
devices or other network segments.
Figure 3-1 SCALANCE XB004-1

Description of the device
3.2 Product characteristics
SCALANCE XB-000
16 Operating Instructions, 12/2015, A2B00077300-06
SCALANCE XB004-2
Possible attachments
The SCALANCE XB004-2 has four RJ-45 jacks and two SC sockets for the connection of
end devices or other network segments.
Figure 3-2 SCALANCE XB004-2

Description of the device
3.2 Product characteristics
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
17
SCALANCE XB004-1LD
Possible attachments
The SCALANCE XB004-1LD has four RJ-45 jacks and an SC socket for the connection of
end devices or other network segments.
Figure 3-3 SCALANCE XB004-1LD

Description of the device
3.2 Product characteristics
SCALANCE XB-000
18 Operating Instructions, 12/2015, A2B00077300-06
SCALANCE XB005
Possible connections
The SCALANCE XB005 has five RJ-45 jacks for connection of end devices or other network
segments.
Figure 3-4 SCALANCE XB005

Description of the device
3.2 Product characteristics
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
19
SCALANCE XB008
Possible connections
The SCALANCE XB008 has eight RJ-45 jacks for the connection of end devices or other
network segments.
Figure 3-5 SCALANCE XB008

Description of the device
3.2 Product characteristics
SCALANCE XB-000
20 Operating Instructions, 12/2015, A2B00077300-06
SCALANCE XB004-1G
Possible attachments
The SCALANCE XB004-1G has four RJ-45 jacks capable of Gigabit and an SC socket for
the connection of end devices or other network segments.
Figure 3-6 SCALANCE XB004-1G

Description of the device
3.2 Product characteristics
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
21
SCALANCE XB004-1LDG
Possible attachments
The SCALANCE XB004-1LDG has four RJ-45 jacks capable of Gigabit and an SC socket for
the connection of end devices or other network segments.
Figure 3-7 SCALANCE XB004-1LDG

Description of the device
3.2 Product characteristics
SCALANCE XB-000
22 Operating Instructions, 12/2015, A2B00077300-06
SCALANCE XB005G
Possible attachments
The SCALANCE XB005G has five RJ-45 jacks capable of Gigabit for connection of end
devices or other network segments.
Figure 3-8 SCALANCE XB005G

Description of the device
3.2 Product characteristics
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
23
SCALANCE XB008G
Possible attachments
The SCALANCE XB008G has eight RJ-45 jacks capable of Gigabit for the connection of end
devices or other network segments.
Figure 3-9 SCALANCE XB008G

Description of the device
3.3 TP ports (twisted pair)
SCALANCE XB-000
24 Operating Instructions, 12/2015, A2B00077300-06
TP ports (twisted pair)
3.3.1
With IE switches of the SCALANCE XB-000 product line, the twisted-pair ports are designed
as RJ-45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of
a network component.
Assignment for SCALANCE XB-000
Assignment for SCALANCE XB-000G
-XP cords with a maximum length of 10 m can be connected to the TP port
With the IE FC cables and IE FC RJ
-45 plug 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.