Siemens SCALANCE X101-1,SCALANCE X101-1LD Operating Instructions Manual

SCALANCE X-100 media converter
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
Industrial Ethernet switches SCALANCE X-100 media converter
Operating Instructions
04/2016
C79000
-G8976-C346-02
Introduction
1
Network topologies
2
Description of the device
3
Installation
4
Connecting up
5
Maintenance
6
Technical specifications
7
Approvals
8
Dimension drawings
9
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
3
Table of contents
1 Introduction ............................................................................................................................................. 5
1.1 On the Operating Instructions ................................................................................................... 5
1.2 On the product .......................................................................................................................... 7
2 Network topologies ............................................................................................................................... 11
2.1 Possible network topologies ................................................................................................... 11
2.2 Coupling of network segments ............................................................................................... 14
3 Description of the device ....................................................................................................................... 15
3.1 Overview of the SCALANCE X-100 media converters ........................................................... 15
3.2 Product characteristics............................................................................................................ 16
3.2.1 SCALANCE X101-1 ................................................................................................................ 16
3.2.2 SCALANCE X101-1LD ........................................................................................................... 17
3.3 TP ports (twisted pair) ............................................................................................................. 18
3.4 FO port (fiber optic) ................................................................................................................. 20
3.4.1 SCALANCE X101-1 ................................................................................................................ 20
3.4.2 SCALANCE X101-1LD ........................................................................................................... 21
3.5 LEDs ....................................................................................................................................... 22
3.6 SET button .............................................................................................................................. 24
3.7 Cascading two media converters ............................................................................................ 26
4 Installation ............................................................................................................................................ 27
4.1 Types of installation ................................................................................................................ 27
4.2 Installation on a DIN rail .......................................................................................................... 28
4.3 Installation on a standard rail .................................................................................................. 30
4.4 Wall mounting ......................................................................................................................... 31
5 Connecting up ....................................................................................................................................... 33
5.1 Wiring rules ............................................................................................................................. 33
5.2 Power supply .......................................................................................................................... 33
5.3 Signaling contact ..................................................................................................................... 35
5.4 Grounding ............................................................................................................................... 36
5.5 IE FC RJ-45 Plug 180 ............................................................................................................. 36
6 Maintenance ......................................................................................................................................... 39
7 Technical specifications ........................................................................................................................ 41
7.1 SCALANCE X101-1 ................................................................................................................ 41
Table of contents
SCALANCE X-100 media converter
4 Operating Instructions, 04/2016, C79000-G8976-C346-02
7.2 SCALANCE X101-1LD .......................................................................................................... 43
8 Approvals ............................................................................................................................................. 47
9 Dimension drawings .............................................................................................................................. 51
Index .................................................................................................................................................... 55
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
5
1
1.1
On the Operating Instructions
Purpose of the Operating Instructions
These operating instructions support you when commissioning networks with the media converters of the SCALANCE X-100.
Validity of the Operating Instructions
These operating instructions are valid for the following devices:
Device
Article number
SCALANCE X101-1 6GK5101-1BB00-2AA3
SCALANCE X101-1LD
6GK5101-1BC00-2AA3
Further documentation
The "SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks" manual contains additional information on other SIMATIC NET products that you can operate along with the media converters of the SCALANCE X-100 product line in an Industrial Ethernet network.
You can order the manual "SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks", release 05/2001, using the following order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian
You will also find this network manual on the Internet pages of Service & Support under the following entry ID: 1172207 (http://support.automation.siemens.com/WW/view/en/1172207
).
You will find further information in the "System Manual Industrial Ethernet" in the Manual Collection.
You will find further information on the SCALANCE system on the Internet at www.siemens.com/scalance (www.siemens.com/scalance
).
You can obtain the "PROFINET Installation Guide" from the PROFIBUS User Organization (PNO).
Audience
These Operating Instructions are intended for persons commissioning networks with SCALANCE X-100 media converters.
Introduction
1.1 On the Operating Instructions
SCALANCE X-100 media converter
6 Operating Instructions, 04/2016, C79000-G8976-C346-02
SIMATIC NET glossary
Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary.
You will find the SIMATIC NET glossary on the Internet at the following address:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045
)
Security information
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. You will find more information about Industrial Security in: Industrial security (http://www.siemens.com/industrialsecurity
)
To stay informed about product updates as they occur, sign up for a product-specific newsletter. You will find more information about this in Product support (https://support.industry.siemens.com/cs/ww/en/ps/15247/pm
)
Introduction
1.2 On the product
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
7
1.2
On the product
What is possible?
The media converters of the SCALANCE X-100 allow the cost-effective installation of Industrial Ethernet linear (bus) and star structures with transitions from one media to another.
The passive use of two identical SCALANCE X-100 media converters in series (cascaded) within a redundant ring is possible. In this case, the media converters behave "like a section of cable". A simple, passive coupling of two rings is also possible. See also "Coupling of network segments (Page 14)".
Note
If devices are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines. These can result, for example, due to lightning or switching of large inductive load
s.
One of the tests used to attest the immunity of these devices to electromagnetic interference is the "surge immunity test" according to EN 61000
-4-5. This test requires overvoltage
protection for the power supply lines. A suitable device is, for exampl
e, the Dehn Blitzductor
BVT AVD 24 V type no. 918 422 or a comparable protective element.
Manufacturer: DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D
-92306 Neumarkt,
Germany
WARNING
When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
WARNING
To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of at least IP54 in compliance with EN 60529.
WARNING
EXPLOSION HAZARD
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
Introduction
1.2 On the product
SCALANCE X-100 media converter
8 Operating Instructions, 04/2016, C79000-G8976-C346-02
WARNING
Ambient temperature above 55 °C
If a device is operated in an ambient temperature of more than 55 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 55 °C.
Scope of delivery
The following components are supplied with a SCALANCE X-100 media converter:
SCALANCE X-100 media converter
2-pin plug-in terminal block (signaling contact)
4-terminal plug-in block (power supply)
● Product information
Accessories
Component
Packaging unit
Article number
IE FC Stripping Tool
1
6GK1 901-1GA00
IE FC blade cassettes
1
6GK1 901-1GB00
IE FC TP standard cable GP
1
6XV1 840 2AH10
IE FC TP trailing cable
1
6XV1 840-3AH10
IE FC TP marine cable
1
6XV1 840-4AH10
IE FC TP trailing cable GP
1
6XV1 870-2D
IE FC TP flexible cable GP 1 6XV1 870-2B
IE FC RJ-45 Plug 180
1
6GK1 901-1BB10-2AA0
IE FC RJ-45 Plug 180
10
6GK1 901-1BB10-2AB0
IE FC RJ-45 Plug 180
50
6GK1 901-1BB10-2AE0
Introduction
1.2 On the product
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
9
Unpacking and checking
WARNING
Do not use any parts that show evidence of damage
If you use damaged parts, there is no guarantee that the device will function according to the specification.
If you use damaged parts, this can lead to the following problems:
• Injury to persons
• Loss of the approvals
• Violation of the EMC regulations
• Damage to the device and other components
Use only undamaged parts.
1. Make sure that the package is complete.
2. Check all the parts for transport damage.
Electrostatic discharge
NOTICE
Electrostatic sensitive devices (ESD)
Electronic modules contain electrostatic sensitive components
These components can easily be destroyed if handled incorrectly.
Note the following instructions to avoid damage.
• Touch electronic modules only when you absolutely need to work on them.
If electronic modules need to be touched, the body of the person involved must first be
electrostatically discharged and grounded.
Do not bring electronic modules in contact with electrically isolating materials such as plastic film, isolating table top pads or clothing made of synthetic fibers.
• Place the modules only on conductive surfaces.
Pack, store and transport electronic modules and components only in conductive
packaging such as metalized plastic or metal containers, conductive foam or household aluminum foil.
Introduction
1.2 On the product
SCALANCE X-100 media converter
10 Operating Instructions, 04/2016, C79000-G8976-C346-02
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
11
2
2.1
Possible network topologies
Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion.
Which topologies can be implemented?
Using the media converters of the SCALANCE X-100 product line, you can implement bus and star topologies. It is also possible to link rings and to use two identical media converters in a ring structure. See also "Cascading two media converters (Page 26)".
Note
Keep to the maximum permitted cable lengths of the devices you are
using. You will find the
permitted cable lengths in the section "
Technical specifications (Page 41)".
Bus topology
Figure 2-1 Example of an electrical/optical bus topology with SCALANCE X101-1
Network topologies
2.1 Possible network topologies
SCALANCE X-100 media converter
12 Operating Instructions, 04/2016, C79000-G8976-C346-02
Star topology
The following figure shows an optical star structure with the IE switches X-400 and X106-1. A SCALANCE W access point and SIMATIC NET 200 systems are electrically connected via the media converters SCALANCE X101-1 or SCALANCE X101-1LD.
Figure 2-2 Example of an optical star topology with SCALANCE X101-1 or SCALANCE X101-1LD
Network topologies
2.1 Possible network topologies
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
13
Ring topology
The following figure shows an electrical ring with a SCALANCE X204IRT as redundancy manager and SCALANCE X208 IE switches. Using the media converters SCALANCE X101­1 or SCALANCE X101-1LD, there is a conversion to an optical section.
Figure 2-3 Example of an electrical ring with SCALANCE X101-1 or SCALANCE X101-1LD
Network topologies
2.2 Coupling of network segments
SCALANCE X-100 media converter
14 Operating Instructions, 04/2016, C79000-G8976-C346-02
2.2
Coupling of network segments
The example of a coupling between two ring networks using two SCALANCE X101-1 media converters is only indirectly possible via nodes capable of redundancy (e.g. SCALANCE X-
400). This applies to all SCALANCE X-100 media converters.
The following figure shows the standby coupling of two redundant rings using the master/slave concept of the SCALANCE X-400 with SCALANCE X101-1 or SCALANCE X101-1LD media converters.
Figure 2-4 Example of a standby coupling of two redundant rings
SCALANCE X-100 media converter Operating Instructions, 04/2016, C79000-G8976-C346-02
15
3
3.1
Overview of the SCALANCE X-100 media converters
Table 3- 1 Overview of the product characteristics
Properties
X101-1
X101-1LD
SIMATIC environment + +
Diagnostics LED
+
+
24 VDC + +
2 x 24 VDC + +
Compact housing 40 mm (securing collar, etc.)
+
+
Signaling contact + on-site operation
+
+
Diagnostics: Web, SNMP, PROFINET
-
-
C-PLUG - -
Ring redundancy with RM
-
-
Passive ring redundancy
+
+
Standby redundancy
-
-
IRT capability - -
Fast learning - -
Passive listening
-
-
Log table - -
SNTP + SICLOCK
-
-
Cut Through + +
Table 3- 2 Overview of the connection options
X101-1
X101-1LD
TP (RJ-45)
Fast Ethernet 10 / 100 Mbps
1 1
Fiber multimode (BFOC)
1300 nm
1 -
Fiber long distance single mode (BFOC) 1310 nm
- 1
Description of the device
3.2 Product characteristics
SCALANCE X-100 media converter
16 Operating Instructions, 04/2016, C79000-G8976-C346-02
3.2
Product characteristics
3.2.1
SCALANCE X101-1
Possible attachments
The SCALANCE X101-1 media converter has an RJ-45 jack and a BFOC socket for connecting end devices or further network segments.
Note
The BFOC socket (Bayonet
Fiber Optic Connector) corresponds to the ST socket.
Figure 3-1 SCALANCE X101-1