Siemens SIMATIC SCALANCE W788C-2 Series, SCALANCE W788C-2 RJ-45, SCALANCE W788C-2 M12 EEC, SCALANCE W788C-2 M12 Operating Instructions Manual

SIMATIC NET
Industrial Wireless LAN SCALANCE W788C-2
Operating Instructions
07/2019
Introduction
1
Security recommendations
2
Description
3
Mounting
4
Connection
5
Technical data
6
Dimension drawings
7
Approvals
8
SCALANCE W788C-2
-14
Siemens AG Digital Industries Postfach 48 48 90026 NÜRNBERG GERMANY
A5E03692120-14
Copyright © Siemens AG 2011 - 2019. All rights reserved
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
ambient conditions must be complied with. The information in the relevant documentation must be observed.

Legal information

Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
07/2019 Subject to change

Table of contents

1 Introduction ............................................................................................................................................. 5
1.1 Information on the Operating Instructions ................................................................................ 5
2 Security recommendations ...................................................................................................................... 7
3 Description ............................................................................................................................................ 11
3.1 Description of the device ........................................................................................................ 11
3.2 Structure of the type designations .......................................................................................... 13
3.3 Components of the product .................................................................................................... 14
3.4 Accessories ............................................................................................................................. 15
3.4.1 Flexible connecting cables and antennas ............................................................................... 17
3.4.1.1 Flexible connecting cables ...................................................................................................... 17
3.4.1.2 Antennas ................................................................................................................................. 18
3.5 LED display ............................................................................................................................. 21
4 Mounting ............................................................................................................................................... 23
4.1 Securing the housing .............................................................................................................. 24
4.2 Wall mounting ......................................................................................................................... 25
4.3 Installing on the S7-300 standard rail ..................................................................................... 26
4.4 Installing on the S7-1500 standard rail_W7x8_11n ................................................................ 27
4.5 Installing on a DIN rail ............................................................................................................. 28
5 Connection ........................................................................................................................................... 31
5.1 Safety when connecting up ..................................................................................................... 31
5.2 Lightning protection, power supply and grounding ................................................................. 32
5.3 Power supply and Ethernet ..................................................................................................... 35
5.4 Antenna connectors ................................................................................................................ 37
6 Technical data ...................................................................................................................................... 41
6.1 Technical specifications of the SCALANCE W788C-2) .......................................................... 41
7 Dimension drawings .............................................................................................................................. 45
8 Approvals .............................................................................................................................................. 47
Index..................................................................................................................................................... 49
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
3
Table of contents
SCALANCE W788C-2
4 Operating Instructions, 07/2019, A5E03692120-14
1
Product
Article number
SCALANCE W788C-2 RJ-45
6GK5788-2FC00-1AA0
SCALANCE W788C-2 M12
6GK5788-2GD00-1AA0
Note Detection of the W788C-2 M12 EEC devices
When the W788C WLC 711, they are shown as W788C
Note
Make sure that you read the explanations and instructions in the README.txt file

1.1 Information on the Operating Instructions

Validity of the Operating Instructions
These operating instructions cover the following products:
SCALANCE W788C-2 M12 EEC 6GK5788-2GD00-1TA0
If information relates to all the named products, the term SCALANCE W7x8 will be used.
These operating instructions apply to the following software version:
SCALANCE W7x8C with firmware as of version 8.31
Purpose of the Operating Instructions
Using the Operating Instructions, you will be able to install and connect the SCALANCE W7x8 correctly. The configuration and the integration of the device in a WLAN are not described in these instructions.
Documentation on the accompanying CD
You will find introductory information about configuration in the document "Getting Started SCALANCE WLC711" on the accompanying SIMATIC NET IWLAN CD under the file name:
GS_SCALANCE-WLC711_76 pdf
-2 M12 EEC devices are detected by the configuration software of the
-2 M12.
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
5
Introduction
1.1 Information on the Operating Instructions
Security information
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please visit (https://www.siemens.com/industrialsecurity)
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’ exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (https://www.siemens.com/industrialsecurity)
Recycling and disposal
The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
Do not dispose of the products at public disposal sites.
For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact (Product return (https://support.industry.siemens.com/cs/ww/en/view/109479891)).
Note the different national regulations.
Trademarks
The following and possibly other names not identified by the registered trademark sign ® are registered trademarks of Siemens AG:
SIMATIC NET, SCALANCE, C-PLUG, RCoax
SCALANCE W788C-2
6 Operating Instructions, 07/2019, A5E03692120-14
2
General
To prevent unauthorized access, note the following security recommendations.
You should make regular checks to make sure that the device meets these recommendations and/or other security guidelines.
Evaluate your plant as a whole in terms of security. Use a cell protection concept with suitable products (https://www.industry.siemens.com/topics/global/en/industrial-
security/pages/default.aspx).
When the internal and external network are disconnected, an attacker cannot access internal data from the outside. Therefore operate the device only within a protected network area.
For communication via non-secure networks use additional devices with VPN functionality to encrypt and authenticate the communication.
Terminate management connections correctly (WBM. Telnet, SSH etc.).
Physical access
Restrict physical access to the device to qualified personnel.
The memory card or the PLUG (C-PLUG, KEY-PLUG, security PLUG) contains sensitive
data such as certificates, keys etc. that can be read out and modified.
Software (security functions)
Keep the firmware up to date. Check regularly for security updates of the product. You will find information on this on the Internet pages "Industrial Security (https://www.siemens.com/industrialsecurity)".
Inform yourself regularly about security advisories and bulletins published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm).
Only activate protocols that you really require to use the device.
Use the security functions such as address translation with NAT (Network Address
Translation) or NAPT (Network Address Port Translation) to protect receiving ports from access by third parties.
Restrict access to the device with a firewall or rules in an access control list (ACL - Access Control List).
If RADIUS authentication is via remote access, make sure that the communication is within the secured network area or is via a secure channel.
The option of VLAN structuring provides good protection against DoS attacks and unauthorized access. Check whether this is practical or useful in your environment.
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
7
Security recommendations
Use a central logging server to log changes and access operations. Operate your logging server within the protected network area and check the logging information regularly.
Use WPA2/ WPA2-PSK with AES to protect the WLAN. If iPCF or iPCF-MC is used, use the AES encryption.
Passwords
Define rules for the use of devices and assignment of passwords.
Regularly update passwords and keys to increase security.
Change all default passwords for users before you operate the device.
Only use passwords with a high password strength. Avoid weak passwords for example
password1, 123456789, abcdefgh.
Make sure that all passwords are protected and inaccessible to unauthorized personnel.
Do not use the same password for different users and systems or after it has expired.
Keys and certificates
This section deals with the security keys and certificates you require to set up HTTPS (HyperText Transfer Protocol Secured Socket Layer).
We strongly recommend that you create your own HTTPS certificates and make them available.
There are preset certificates and keys on the device. The preset and automatically created HTTPS certificates are self-signed.
We recommend that you use HTTPS certificates signed either by a reliable external or by an internal certification authority. The HTTPS certificate checks the identity of the device and controls the encrypted data exchange. You can install the HTTPS certificate via the WBM (System > Load and Save).
Handle user-defined private keys with great caution if you use user-defined SSH or SSL keys.
Use the certification authority including key revocation and management to sign the certificates.
Verify certificates and fingerprints on the server and client to avoid "man in the middle" attacks.
We recommend that you use certificates with a key length of 2048 bits.
Change keys and certificates immediately, if there is a suspicion of compromise.
SCALANCE W788C-2
8 Operating Instructions, 07/2019, A5E03692120-14
Security recommendations
Secure/non-secure protocols and services
Avoid and disable non-secure protocols, for example Telnet and TFTP. For historical
reasons, these protocols are still available, however not intended for secure applications. Use non-secure protocols on the device with caution.
Check whether use of the following protocols and services is necessary:
– Non-authenticated and unencrypted ports
– LLDP
– Syslog
– DHCP options 66/67
– TFTP
The following protocols provide secure alternatives:
SNMPv1/v2 → SNMPv3
Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure. Use the option of preventing write access. The product provides you with suitable setting options.
Use secure protocols when access to the device is not prevented by physical protection
To prevent unauthorized access to the device or network, take suitable protective
If you require non-secure protocols and services, operate the device only within a
Restrict the services and protocols available to the outside to a minimum.
For the DCP function, enable the "Read Only" mode after commissioning.
Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
If SNMP is enabled, change the community names. If no unrestricted access is necessary, restrict access with SNMP.
Use SNMPv3 in conjunction with passwords.
HTTP → HTTPS
Telnet → SSH
measures.
measures against non-secure protocols.
protected network area.
Protocol
Port
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
9
Security recommendations
Protocol
Port number
Port status
Factory setting of the port
Authentication
SSH (when configured)
TELNET
HTTP (when configured)
HTTPS (when configured)
SNTP NTP
SNMP (when configured)
PROFINET UDP/49154, 49155
Syslog (when configured)
EtherNet/IP UDP/2222,44818
(when configured)
DHCP (when configured)
RADIUS
TFTP (when configured)
Port status
– Open
The port is always open and cannot be closed.
– Open (when configured)
The port is open if it has been configured.
Factory setting
– Open
The factory setting of the port is "Open".
– Closed
The factory setting of the port is "Closed".
Authentication
Specifies whether or not the protocol is authenticated.
Encryption
Specifies whether or not the transfer is encrypted.
TCP/22 Open
TCP/23 Open
(when configured)
TCP/80 Open
TCP/443 Open
UDP/161 Open
UDP/514 Open
UDP/67,68 Open
UDP/69 Open
UDP/123 Open
(when configured)
UDP/34964,
TCP/44818,
UDP/1812,1813 Open
Open Open No
Open
(when configured)
Open Yes
Open Yes
Open Yes
Open Yes
Closed No
Open Yes
Open No
Open No
Closed No
Closed No
Closed No
SCALANCE W788C-2
10 Operating Instructions, 07/2019, A5E03692120-14
3
LEDs
Connector for power supply
Connector for Ethernet, RJ-45 type
- PLUG compartment (not with W788C)
Connector for the digital input/output (not with W788C)
PLUG compartment (not with W788C)
Reset button
Grounding connector (thread M4) on the back of the device

3.1 Description of the device

SCALANCE W7x8x-x RJ45 - IP30 degree of protection
Connecting connectors, R-SMA type female
Devices with one IWLAN interface: 3 connectors on the top (covered in the figure).
Devices with two IWLAN interfaces: 3 connectors on the top and 3 on the underside.
Screw-down cover for the
- reset button and the
Figure 3-1 SCALANCE W7x8 RJ45
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
11
Description
LEDs
Connector for the supply voltage, type M12 (with cover)
Connector for Ethernet, M12 type (with cover)
- PLUG compartment (not with W788C)
PLUG compartment (not with W788C)
Reset button (covered in the figure)
Grounding connector (thread M4) on the back of the device
3.1 Description of the device
SCALANCE W7x8x-x M12 - IP65 degree of protection
Connecting connectors, N-Connect type female
Devices with one IWLAN interface: 3 connectors on the top (covered in the figure).
Devices with two IWLAN interfaces: 3 connectors on the top and 3 on the underside.
Screw-down cover for the
- reset button and the
Figure 3-2 SCALANCE W7x8 M12
SCALANCE W788C-2
12 Operating Instructions, 07/2019, A5E03692120-14
Description

3.2 Structure of the type designations

3.2 Structure of the type designations
The type designation of a SCALANCE W7x8 is made up of several parts that have the following meaning:
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
13
Description
Note
The mounting set with the holding plate does not ship with the device, see (Page

3.3 Components of the product

3.3 Components of the product
The following components are supplied with the product:
SCALANCE W7x8
Only with device variant M12 / IP65:
– 2 protective caps for the M12 sockets
Only with device variant RJ-45 / IP30:
– 4-pin terminal block for the supply voltage
– 4-pin terminal block for the digital input/output
2 screws for mounting on an S7-300 standard rail
SIMATIC NET Industrial Wireless LAN CD
Accessories
15).
Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office.
SCALANCE W788C-2
14 Operating Instructions, 07/2019, A5E03692120-14
Description
Component
Description
Article number
rail and for mast mounting with additional hose clips
Component
Description
Article number
package
Component
Description
Article number
4 x 2 (24 AWG); 180° cable outlet
package
per package
Component
Description
Article number
Sold by the meter
* Available in different lengths

3.4 Accessories

3.4 Accessories
Technical data subject to change.
You will find further information on the range of accessories in the Industry Mall (https://mall.industry.siemens.com)
Mounting set
Mounting set Mounting set can only be used in conjunction with
SCALANCE W-786; consisting of holding plate for wall mounting, for mounting on an S7-300 rail and a DIN
Plug-in connector Industrial Ethernet
For the M12 variants the following plug-in connector is required:
IE FC M12 PLUG PRO 4 x 2
For the RJ-45 variants the following plug-in connector is required:
IE FC RJ45 PLUG 180 4 x 2
Industrial Ethernet FastConnect M12 Plug PRO 4 x 2 M12 plug-in con­nector with rugged metal housing and FC connector technology, with axial cable outlet (X coded)
Industrial Ethernet FastConnect RJ45 Plug 180 4 x 2, RJ45 plug-in connector; CAT6A; (10/100/1000/10000 Mbps) with rugged metal housing and FC con­nector technology, for IE FC Cable
1 connector per
8 connectors per package
1 connector per
10 connectors
50 connectors per package
6GK5798-8MG00-0AA0
6GK1901-0DB30-6AA0
6GK1901-0DB30-6AA8
6GK1901-1BB12-2AA0
6GK1901-1BB12-2AB0
6GK1901-1BB12-2AE0
Cables Industrial Ethernet
IE FC TP cable 4 x 2
SCALANCE W788C-2 Operating Instructions, 07/2019, A5E03692120-14
Industrial Ethernet FastConnect TP standard cable GP 4 x 2, TP installation cable CAT6A for connection to IE FC RJ45 Plug 4 x 2, 24 AWG
6XV1878-2A
15
Loading...