Siemens RUGGEDCOM WIN5114-V, RUGGEDCOM WIN5114, RUGGEDCOM WIN5214, RUGGEDCOM WIN5151 Series, RUGGEDCOM WIN5151-AC Installation Manual

...
0 (0)
Preface

RUGGEDCOM WIN5114-V

Installation Guide
Introduction
Installing the Subscriber Unit
Device Management
Technical Specifications
Certification
1
2
3
4
5
10/2018
RC1310-EN-03
RUGGEDCOM WIN5114-V
Installation Guide
Copyright © 2018 Siemens Canada Ltd All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized
except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration.
This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of Siemens Canada Ltd.
Disclaimer Of Liability
Siemens has verified the contents of this document against the hardware and/or software described. However, deviations between the product and the documentation may exist.
Siemens shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this material.
The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice.
Registered Trademarks
RUGGEDCOM™ and ROS™ are trademarks of Siemens Canada Ltd. Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the
owner.
Security Information
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit https://www.siemens.com/industrialsecurity.
To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit https://
support.automation.siemens.com.
Warranty
Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. The warranties set forth in this article are exclusive and are in lieu of all other warranties, performance guarantees and conditions whether written or oral, statutory, express or implied (including all warranties and conditions of merchantability and fitness for a particular purpose, and all warranties and conditions arising from course of dealing or usage or trade). Correction of nonconformities in the manner and for the period of time provided above shall constitute the Seller’s sole liability and the Customer’s exclusive remedy for defective or nonconforming goods or services whether claims of the Customer are based in contract (including fundamental breach), in tort (including negligence and strict liability) or otherwise.
For warranty details, visit https://www.siemens.com/ruggedcom or contact a Siemens customer service representative.
Contacting Siemens
Address
Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7
Telephone
Toll-free: 1 888 264 0006 Tel: +1 905 856 5288 Fax: +1 905 856 1995
E-mail
ruggedcom.info.i-ia@siemens.com
Web
https://www.siemens.com/ruggedcom
ii
RUGGEDCOM WIN5114-V
Installation Guide

Table of Contents

Table of Contents
Preface ............................................................................................................. v
Alerts .................................................................................................................................................. v
Related Documents ............................................................................................................................. vi
Training .............................................................................................................................................. vi
Customer Support ............................................................................................................................... vi
Chapter 1
Introduction ..................................................................................................... 1
1.1Feature Highlights ........................................................................................................................ 2
1.2Description ................................................................................................................................... 2
1.3Required Tools and Materials ......................................................................................................... 3
1.4Decommissioning and Disposal ...................................................................................................... 4
Chapter 2
Installing the Subscriber Unit ............................................................................ 5
2.1General Procedure ........................................................................................................................ 6
2.2Unpacking the Subscriber Unit ....................................................................................................... 7
2.3Site Preparation and Precautions .................................................................................................... 7
2.4Mounting the Subscriber Unit ........................................................................................................ 8
2.4.1Mounting the Subscriber Unit to a Wall or Tower ................................................................. 9
2.4.2Mounting the Subscriber Unit to a Pole ............................................................................. 10
2.5Installing the Antennas ............................................................................................................... 12
2.6Grounding the Subscriber Unit ..................................................................................................... 13
2.7Connecting Power and Data ........................................................................................................ 14
2.8Weatherproofing the Subscriber Unit ............................................................................................ 14
2.8.1Weatherproofing a Cable .................................................................................................. 15
2.8.2Applying Cold Shrink Tubing ............................................................................................. 15
2.8.3Applying Self-Amalgamating Tape ..................................................................................... 16
Chapter 3
Device Management ....................................................................................... 17
3.1Configuring the Subscriber Unit ................................................................................................... 17
Chapter 4
Technical Specifications .................................................................................. 19
4.1Power Supply Requirements ........................................................................................................ 19
iii
Table of Contents
RUGGEDCOM WIN5114-V
Installation Guide
4.2Power Consumption .................................................................................................................... 19
4.3Radio and Modem Specifications .................................................................................................. 19
4.4Operating Environment ............................................................................................................... 20
4.5Mechanical Specifications ............................................................................................................ 20
4.6Dimension Drawings ................................................................................................................... 21
Chapter 5
Certification .................................................................................................... 23
5.1Approvals ................................................................................................................................... 23
5.1.1 CSA ................................................................................................................................. 23
5.1.2European Union (EU) ....................................................................................................... 24
5.1.3TÜV Rheinland ................................................................................................................. 24
5.1.4 IEEE ................................................................................................................................ 24
5.1.5 RoHS ............................................................................................................................... 24
5.2Environmental Type Tests ............................................................................................................ 25
iv
RUGGEDCOM WIN5114-V
Installation Guide

Preface

This guide describes the RUGGEDCOM WIN5114-V. It describes the major features of the subscriber unit, installation, commissioning and important technical specifications.
It is intended for use by subscriber unit installers and operators, and assumes readers have a working knowledge of WiMAX technologies and procedures. While some safety precautions are reviewed here, it is assumed that installers are trained in safe installation practices. Users unfamiliar with safe installation procedures, WiMAX technologies, and service procedures should not rely on this manual for comprehensive guidance.
CONTENTS
“Alerts”
“Related Documents”
“Training”
“Customer Support”
Preface

Alerts

The following types of alerts are used when necessary to highlight important information.
DANGER!
DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death or serious injury.
WARNING!
WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/or equipment damage.
CAUTION!
CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage.
IMPORTANT!
IMPORTANT alerts provide important information that should be known before performing a procedure or step, or using a feature.
NOTE
NOTE alerts provide additional information, such as facts, tips and details.
Alerts v
Preface
RUGGEDCOM WIN5114-V
Installation Guide

Related Documents

Other documents that may be of interest include:
RUGGEDCOM SU User Guide [https://support.industry.siemens.com/cs/ww/en/view/109737453]

Training

Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs, experience and application.
Siemens' Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastructure technologies.
Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility, transportation and industrial markets, allows Siemens to provide training specific to the customer's application.
For more information about training services and course availability, visit https://www.siemens.com/ruggedcom or contact a Siemens Sales representative.

Customer Support

Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods:
Online
Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
Telephone
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit http://
www.automation.siemens.com/mcms/aspa-db/en/automation-technology/Pages/default.aspx.
Mobile App
Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to:
• Access Siemens' extensive library of support documentation, including FAQs and manuals
• Submit SRs or check on the status of an existing SR
• Contact a local Siemens representative from Sales, Technical Support, Training, etc.
• Ask questions or share knowledge with fellow Siemens customers and the support community
vi Related Documents
RUGGEDCOM WIN5114-V
Installation Guide

Introduction

The RUGGEDCOM WIN5114-V subscriber unit is part of the RUGGEDCOM WIN family, a line of mobile WiMAX broadband wireless access systems based on the IEEE 802.16e mobile WiMAX standard.
The RUGGEDCOM WIN5114-V is a high-performance, self-learning subscriber. It automatically detects the base station on the best signal available, allowing for plug-and-play installation and maintenance free operation. The automatic switching and monitoring features guarantee on-going operation in changing conditions, which results in low maintenance and considerable operating expense savings.
The subscriber unit is compliant with IEEE 802.16e standards to effectively meet the unique requirements of the wireless Metropolitan Area Network (MAN) environment and to deliver broadband access services to a wide range of customers. Specifically designed for point-to-multipoint broadband wireless access applications, the subscriber unit provides efficient use of the wireless spectrum, supporting a range of user environments.
The subscriber unit also complies with the IEEE 802.16-2005 standard for the deployment of point-to-multipoint (PMP) and point-to-point (PTP) network architectures.
The subscriber unit is a WiMAX Forum IEEE 802.16e Wave 2 (MIMO) certified subscriber. Each subscriber registers and establishes a bi-directional data link with the base station.
Primary benefits offered by the RUGGEDCOM WIN5114-V include:
Non-Line-of-Sight (NLOS) Propogation
Provides excellent performance in NLOS conditions. Mitigates multi-path and deep fading, providing extended range and easy installation.
Automatic Transmit Power Control (ATPC)
ATPC allows for optimal network deployment, tight frequency reuse, and interference avoidance.
Wide Frequency Band
Provides support for deployments around the world.
Chapter 1
Introduction
CONTENTS
Section1.1, “Feature Highlights”
Section1.2, “Description”
Section1.3, “Required Tools and Materials”
Section1.4, “Decommissioning and Disposal”
1
Chapter 1
4
3
1
8
6
5
7
2
RSSI
W.LINK PWR
Introduction
Section1.1
RUGGEDCOM WIN5114-V
Installation Guide

Feature Highlights

Long Range
The subscriber unit has multiple built-in receivers to improve range and Non-Line-of-Sight (NLoS) performance. The system has the ability to leverage sub-channelization technology to balance links with high-power base stations.
Robust Design
The subscriber unit is designed for mission critical applications in harsh environments with very high Mean Time Before Failure.
Quality of Service
The subscriber unit gives the user the ability to separate traffic types over the air, and guarantee latency, minimum bandwidth and jitter according to application needs.
Flexibility
The subscriber unit supports both IP convergence sublayer for wireless Internet service providers or Ethernet Convergence Sublayer, ideal for mission critical private networks.
Section1.2

Description

The RUGGEDCOM WIN5114-V features various ports, controls and indicator LEDs on the bottom panel for connecting, configuring and troubleshooting the subscriber unit.
Figure1:RUGGEDCOM WIN5114-V
1.ETH Port 2.PWR Port 3.ANT 1 Port 4.ANT 2 Port 5.RSSI LEDs 6.W.LINK LED 7.PWR LED 8.Chassis Ground
2 Feature Highlights
RUGGEDCOM WIN5114-V
Installation Guide
Chapter 1
Introduction
12VDC Port A 4-pin, female, D-Coded M12 port for power. For more information about connecting data
ANT 1 and ANT 2 Ports Ports for connecting primary and secondary external antennas. For information about
RSSI LEDs Indicates the received signal strength.
W.LINK LED Indicates when the subscriber unit is connected with a base station.
and power, refer to Section2.7, “Connecting Power and Data”.
connecting the antennas, refer to Section2.5, “Installing the Antennas”.
LED RSSI Level
< -90
-85 to -90
-80 to -85
-75 to -80
-70 to -75
-65 to -70
-20 to -60
> -20
State Description
Green (Solid) Subscriber unit is connected to the base
station and receiving services.
Green (Blinking) Link between the subscriber unit and the
PWR LED Indicates when power is supplied to the subscriber unit.
State Description
Green Power is on.
Off Power is off.
ETH Port A 4-pin, female, D-Coded M12 port for data.
Chassis Ground Connection Protects the subscriber unit from power surges and accumulated static electricity. For
information about grounding the subscriber unit, refer to Section2.6, “Grounding the
Subscriber Unit”.
base station is down.
Section1.3

Required Tools and Materials

The following tools and materials are required to install the RUGGEDCOM WIN5114-V:
Tools
• Wrench or socket set
• Phillips screwdriver
• Drill with an 8 mm (5/16 in) drill bit
• Wall anchors (if necessary)
Greases
• Marine grease (for marine applications only)
Tapes
• POE cold shrink (maximum 49.2 mm or 1.9 in inner diameter before shrinking) or self-amalgamating tape
Required Tools and Materials 3
Chapter 1
Introduction
RUGGEDCOM WIN5114-V
Installation Guide
Sprays
• Cleaner and de-greaser
• SCC3 conformal coating
• Corrosion protection
Section1.4
• UV-resistant vinyl tape
• Electrical insulation putty
Mounting Hardware (Wall/Tower Only)
• Four 1/4" × 1/2" HEX chipboard screws
• Four 1/4" flat washers
• Four 1/4" spring washers

Decommissioning and Disposal

Proper decomissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment.
Decommissioning
This device may include sensitive, proprietary data. Before taking the device out of service, either permanently or for maintenance by a third-party, make sure it has been fully decommissioned.
For more information, refer to the associated User Guide.
Recycling and Disposal
For environmentally friendly recycling and disposal of this device and related accessories, contact a facility certified to dispose of waste electrical and electronic equipment. Recycling and disposal must be done in accordance with local regulations.
4 Decommissioning and Disposal
Loading...