Room thermostats with KNX communications
RDG100KN RDG160KN
Page 2
Page 3
Page 4
DIP switches
ON
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
(B1)
M1
Y1
T
B2
T
T
(B1)
Y1
M1
30
76
S
02
_0
1
T
YE
T
(B1)
T
(B1)
B2
(B1)
M1
Y1
T
B2
T
T
(B1)
YR
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
Y1
M1
T
B2
T
(B1)
T
(B1)
Y2
T
Y2
Y1
M1
(B1)
T
(B1)
T
Y2
Y1
M1
307
6S0
5
_0
1
(B1)
T
(B1)
YE
B2
Product no.
Control outputs
Fan
RDG100KN
On/Off, PWM, 3-position
3-speed, 1-speed
RDG160KN
DC 0...10 V
3-speed, 1-speed, DC 0...10 V
RDG160KN
On/Off
DC 0...10 V
Remote configuration
Page 5
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
/ floor heating
1 2 3 4 5
ON
OFF
3191S11
N1
T
B1
T
B2
T
D3
Y1
3191S12
N1
T
YE
B1
T
B2
T
D3
Y1
3191S14
N1
T
B1
T
B2
T
D3
Y1
YR
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
Y1
Y2
3191S13
N1
T
B1
T
D3
Y1
YR
Product no.
Control outputs
RDG100KN
On/Off, PWM, 3-position
RDG160KN
On/Off, DC 0...10 V
Page 6
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
3181S31
N1
T
B1
T
D3
3181S32
N1
T
YE
B1
T
D3
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
3181S35
N1
T
B1
T
D3
3181S36
N1
T
B1
T
D3
2
Product no.
Control outputs
Fan
RDG160KN
On/Off , DC 0...10 V
Disabled, DC 0...10 V
Key
Y1 Heating or heating / cooling valve actuator
M1 1-speed or 3-speed fan
Y2 Cooling valve actuator YE Electric heater
B1 Return air temperature sensor or external room
temperature sensor (optional)
B2 Changeover sensor (optional)
Notes
Page 7
Product no.
Stock no.
Features
voltage
LCD
On/Off
PWM
3-pos.
DC
3-stage
DC
RDG100KN
S55770-T163
AC 230 V
3 1)
2 1)
2 1)  
2 2)
2
2)
2
3)
sheet
changeover sensor
Condensation motion
QXA2601 /
QXA2604
3302
(only available in AP, UAE, SA and IN)
(only available in AP, UAE, SA and IN)
AC 230 V, NO
AC 24 V, NO
(for small valves 2.5 mm), NC
(for radiator valves)
(for 2- and 3-port valves / V…P45)
(for small valves 2.5 mm)
(for small valves 5.5 mm)
(for small valve 5,5 mm)
(for valves 5.5 mm)
On / off actuators
On / off and PWM actuators *)
3-position actuators
Page 8
Electrical actuator, DC 0...10 V (for radiator valves)
(for 2- and 3-port valves / V…P45)
(for small valves 2.5 mm)
(for small valves 5.5 mm)
(for CombiValves VPI45)
(for valves 5.5 mm)
AC 24 V, NO, DC 0…10 V, 1 m
Note:
max 10 SQS65 actuators (DC)
Product no. / stock no.
Data sheet
KNX Power supply 160 mA (Siemens BT LV)
5WG1 125-1AB02
--
KNX Power supply 320 mA (Siemens BT LV)
5WG1 125-1AB12
--
KNX Power supply 640 mA (Siemens BT LV)
5WG1 125-1AB22
--
DC 0…10 V actuators
Page 9
1) Operating mode button / Esc
Operation and settings
1
3
Page 10
#
Symbol
Description
#
Symbol
Description
Digits for room temperature and setpoint
Additional user information, like out-
Temporary timer function; visible when
Display
Page 11
from a heating / cooling device, and not exposed to drips or splash water.
Comply with local regulations to wire, protection and earth the thermostat.
have a circuit breaker with a rated current of no more than 10 A.
230 V mains voltage.
Use only valve actuators rated for AC 230 V.
local regulations.
Sensor cables must be suited for AC 230 V mains voltage
external equipment to the relay outputs.
conduit box carries AC 230 V mains voltage.
Disconnect from supply before removing from the mounting plate.
controllers must be switched off.
Page 12
L
N Y1
Y2
X1 M
X2
N1
3191A03
Q1 Q2
Q3
CE+ CE-
KNX
KNX
V24
ETS
RS232
Siemens N148 / UP146 / UP152
KNX
USB
ETS / ACS
Siemens OCI700
D1
GND
Y3 Y4
Applications
Note
Connect tool
Note
Control parameters
Page 13
Application
Factory setting P01
2-pipe and chilled / heated ceiling, and 2-stage
1 = Cooling only
4-pipe, chilled ceiling and radiator
4 = Heating and cooling
Control sequence
Calibrate sensor
Setpoint and range limitation
Programming mode
addresses
KNX serial number
Page 14
Rated voltage
AC 230 V
Frequency
50/60 Hz
Power consumption
Max. 8 VA / 1 W
No internal fuse External preliminary protection with max
required in all cases
Fan control Q1, Q2, Q3 – N
AC 230 V
Rating min, max resistive (inductive)
5 mA...5(4) A
No internal fuse
External preliminary protection with max. C 10 A circuit breaker in the supply line required under all circumstances
Fans must NOT be connected in parallel!
Connect one fan directly, for additional fans, one relay for each speed.
Control outputs
Solid state (Triac) AC 230 V,
3
be exchanged
Multifunctional inputs
QAH11.1 (NTC)
0...49 °C Max. 80 m
Selectable (NO/NC) DC 0…5 V, max. 5 mA
Max. 20 thermostats per switch.
t mix with D1!
N/A, mains potential
Selectable (NO/NC) SELV DC 6…15 V, 3…6 mA Max. 20 thermostats per switch.
Do not mix with X1 / X2!
3.75 kV, reinforced insulation
Function of inputs
heater contact, fault contact, monitoring input
Selectable
RDG100KN
Power supply
Caution
Outputs
Caution
STOP
Note!
Inputs
Page 15
Rated voltage
DC 24 V : Make sure to connect G to + and G0 to -
AC 24 V DC 24 V
Frequency
50/60 Hz
Power consumption
Max. 2 VA / 2 W
No internal fuse External preliminary protection with max
required in all cases
Q1 / Q2 / Q3 / L - N (relay)
AC 24...230 V
Use for 3-speed fan control
Rating min, max resistive (inductive)
5 mA...5(4) A
Fans must NOT be connected in parallel!
Connect one fan directly, for additional fans, one relay for each speed.
Use for actuator control (Q1, Q2)
Q1 - rating min, max resistive (inductive)
5 mA...1 A
Q2 - rating min, max resistive (inductive)
5 mA...5(4) A
Use for external equipment (Q3)
Rating min, max resistive / inductive Qx
5 mA…1 A
No internal fuse External preliminary protection with max. C 10 A circ
required under all circumstances
ECM fan control Y50 - G0
SELV DC 0...10 V, Max. ±5 mA
Actuator control Y10 - G0 / Y20 - G0 (G)
SELV DC 0...10 V, Max. ±1 mA
Multifunctional inputs
thermostats for one switch
SELV
QAH11.1 (NTC)
0...49 °C Max. 80 m
Selectable (NO/NC) DC 0…5 V, max. 5 mA Max. 20 thermostats per switch
Selectable (
DC 6…15 V, 3…6 mA Max. 20 thermostats per switch.
Function of inputs
supply air temperature
Selectable
RDG160KN
Caution
Outputs
STOP
Caution
Inputs
Page 16
Interface type
KNX, TP1
(electrically isolated)
Bus current
20 mA
Bus topology: See KNX manual (reference documentation, see below)
Switching differential, adjustable
2
1 K (0.5…6 K)
Setpoint setting and setpoint range
Protection (P65-P66)
21 °C (5…40 °C) 15 °C/30 °C (OFF, 5..
8 °C/OFF (OFF, 5..40 °C)
Multifunctional inputs X1 / X2 / D1
Selectable (
1 (
0 (n
3 (
Built
Temperature calibration range
0…49 °C <
± 3.0 K
Settings and display res
Current temperature value displayed
0.5 °C
0.5 °C
Operation
Humidity
IEC 721-3-3 Class 3K5 0
<95% r.h.
Transport
Mechanical conditions
IEC 721-3-2 Class 2K3
<
Class 2M2
Storage
Humidity
IEC 721-3-1 Class 1K3
-
<95% r.h.
EU conformity (CE)
Product standards
Automatic electric controls for household and
similar use
EN60730–1
EN
2.B (micro
operation)
Electromagnetic compatibility
2004/108/EC
RDG100KN, RDG160KN
KNX bus
Operational data
Environmental conditions
Standards and directives
Page 17
Low
2006/95/EC
RCM Mark conformity (Emission)
AS/NZS 61000-6-3
Reduction of
2011/65/E
EN50581
Safety class
II as per EN60730
Pollution class
Normal
Degree of protection of housing
IP30 as per EN60529
The product environmental declaration CE1E3181
*)
tally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).
Meets the requirements for eu.bac certification
See product list at: http://www.eubaccert.eu/licences-by-criteria.asp
RDG160KN (License 213356)
Energy Effi
ciency Label
accuracy [K]
Fancoil unit systems (2 pipes 2 wires)
AA
Heating 0.1
(Motorised actuator DC, variable fan speed)
Cooling 0.1
Fancoil unit systems (4 pipes)
A
Heating 0.4
(Thermal actuator 2-pt, variable fan speed)
Cooling 0.4
Connection terminals
Solid wires or stranded wires with wire end sleeves 1 x 0.4…2.5 mm
or 2 x 0.4…1.5 mm2
Minimal wiring cross section on
L, N, Q1, Q2, Q3, Y1, Y2, Y3, Y4
min 1.5 mm
2
Housing front color
RAL 9003 white
Weight without / with packaging
RDG160KN
0.270 kg / 0.380 kg
0.240 kg / 0.320 kg
Reference documentation
books/index.php)
Synco
CE1P3127 Communication via the KNX bus for Synco 700, 900 and RXB/RXL Basic documentation
CM1Y9779 Working with ETS
Environmental Compatibility
eu.bac
General
Caution
Page 18
L
X1 M
N
Q1
Q2 Q3
Y1
SELV
X2
3191A01
CE+ CE
-
D1 GND
Y2 Y3 Y4
L
G X1 M G0
Q1 Q2 Q3
Y50
SELV
X2
3191A11
CE+ CE
-
D1 GND
Y10 Y20
CE- KNX data –
Page 19
2-stage
1.
2.
N1 Room thermostat RDG100KN
M1 1- or 3-speed fan
1st / 2nd 1st / 2nd stage
Page 20
DC 0...10 V fan
1- / 3-speed fan
Page 21
1st / 2nd 1st / 2nd stage
128.0
93.0
28.2
27.8
28.5
16.0
9.0
28.3
28.3
27.7
28.3
4.0
4.0
30.8
28.3
28.3