Siemens RDE100.1RF Operating Instructions Manual

Page 1
1/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
s
Operating Instructions
RDE100.1RF
1 Display
Indicates that batteries
need to be replaced
Time of day
Frost protection (heating) active
Morning: 12-hour format
Afternoon: 12-hour format
Auto Timer mode
Confirmation
View and set Auto Timer
F
Room temperature in
degrees Fahrenheit
Comfort mode
C
Room temperature in degrees Celsius
Economy mode
Button lock activated
Escape
Room temperature,
setpoint, etc
External input enabled
Display of zone
(default = 1)
Permanent setpoint
setting
Heating On
Weekday and time of day setting
Weekday 1 = Monday
Weekday 7 = Sunday
Holiday mode setting
Timer bar
Current room temperature
2 Change operating mode
3 Set
4 Ok
5 Decrease value
6 Increase value
7 Battery holder
RDE-MZ6
To be purchased separately
Do you want to set the time of day and the weekday?
Set
Ok
+ –
Mode
Proceed as follows:
Press Set and select
Press Ok and the time of day flashes for setting
Press
+ or to adjust the time of day
Press Ok to confirm
The weekday flashes; press
+ or to select the desired day
Press Ok to save the setting
Press Mode to exit or wait for the program to exit automatically
Page 2
2/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Are your rooms too warm/too cold?
+
Ok
Set
Mode
Press + or
to increase or decrease the
room temperature setpoint in increments of
0.5 °C/1 °F. Proceed as follows:
Press
+ or to change the setpoint
temporarily. This readjustment is reset as soon as the operating mode changes
Press Ok, Set or Mode to save the setting or wait for the program to exit automatically
To lock the setpoints, use parameters P06 and P08
Do you want to change the operating mode?
Mode
!
The thermostat provides Comfort, Economy and automatic mode. Changeover between the operating modes can be made manually by pressing Mode.
Comfort mode is the permanent (24 h)
selection of Comfort. Select this operating mode to maintain Comfort temperature permanently without any time switch. It is used during occupancy periods, for example.
Economy mode is the permanent (24 h)
selection of Economy. Select this operating mode to maintain the Economy temperature permanently without any time switch. It is used during non-occupancy periods (e.g. at night).
AUTO
In Auto Timer mode, the operating
modes (Comfort, Economy) are changed automatically according to the time switch setting.
Note:
Frost protection is a function always active
in the background. As soon as the room temperature falls below 5 ºC, the unit
automatically activates heating
.
Do you want to set permanent temperature setpoints?
Set
Ok
+ –
Mode
!
Press Set and select
Press Ok to confirm
Press Mode to select the operating
mode (Comfort or Economy)
Press
+ or to adjust the setpoint
permanently
Press Ok to confirm
Press Mode to exit or wait for a timeout
to exit automatically
Note:
This permanent setpoint is used during Auto Timer mode.
Energy saving tips without loss of comfort
Select Auto Timer mode for the heating period, and
set the time switch according to your normal habits at home
Select Economy or Holiday mode for longer periods of non-occupancy and the summer period
Do you want to set your Holiday mode?
Set
Ok
+ –
Mode
!
Use the Holiday mode to set the thermostat to a constant room temperature while absent.
Press Set and select
Press Ok to confirm
Press
+ or to adjust the temperature
setpoint
Press Ok to confirm
Press
+ or – to set the number of days
for holidays (0 = Holiday mode Off)
Press Ok to save the setting
When Holiday mode is activated, the
remaining days are displayed
Note:
If you press Mode while Holiday mode is active, the
function is deactivated and symbol
disappears.
If the Comfort and Economy setpoints are both locked, the lowest locked setpoint is the Holiday mode setpoint. You can adjust the setpoint from 5 ºC up to the lowest locked setpoint
.
Do you want to enter your own time switch?
Option 1: Time switch with individual day settings (P11=0)
Set
Ok
+ –
Mode
You can select Comfort or Economy mode in steps of 15 minutes throughout the day. The 0:00 to 24:00 hour time bar allows you to set the operating mode for the selected day(s).
Example:
0 6 12 24
18
1 2
Visible bars: Control to Comfort temperature
Invisible bars: Control to Economy temperature
When Auto Timer mode is enabled, changeover between the operating modes is automatic after the settings are saved.
Proceed as follows:
1) Press Set and select
AUTO
.
2) Press Ok to confirm.
3) Time switch for Mon (1) is displayed.
4) Press
+ or to select the weekday, from
Mon(1) to Sun(7).
5) Press Ok to confirm the selection and initiate time programming.
During programming:
6) Press Mode to select the operating mode (Comfort or Economy) or
7) Press
+ or to set the time in steps of
15 minutes for the selected mode.
8) Press Ok to save the time switch.
9) Repeat steps 4-8 for all remaining days (if required) or
10) Press Mode or wait for the program to exit automatically.
Page 3
3/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Option 2: Time switch with the same 7-day settings (P11=1)
Set
Ok
+ –
Mode
You can set the time switch so that all settings apply to the 7 weekdays.
Example:
0 6 12 24
18
1 2
Visible bars: Control to Comfort temperature
Invisible bars: Control to Economy temperature
Proceed as follows:
1) Set the parameter (P11=1). Please refer to section "Do you want to change parameters".
2) Press Set and select
AUTO
.
3) Press Ok to confirm.
4) Time switch for Mon (1) - Sun (7) is
displayed.
5) Press Ok to initiate time programming.
During programming:
6) Press Mode to select the operating mode (Comfort or Economy) or
7) Press
+ or to set the time in steps of 15
minutes for the selected mode.
8) Press Ok to save the time switch.
9) Press Mode or wait for the program to exit automatically.
Option 3: Time switch with 5-2-day settings (P11=2)
Set
Ok
+ –
Mode
You can set Monday - Friday and Saturday ­Sunday at the same time.
Example:
0 6 12 24
18
1
2
Visible bars: Control to Comfort temperature
Invisible bars: Control to Economy temperature
Proceed as follows:
1) Set the parameter (P11=2). Please refer to section "Do you want to change parameters".
2) Press Set and select
AUTO
.
3) Press Ok to confirm.
4) Time switch for Mon (1) – Fri (5) is
displayed.
5) Press
+ or to select Mon (1) – Fri ( 5)
or Sat (6) - Sun (7).
6) Press Ok to confirm the selected period and initiate time programming.
During programming:
7) Press Mode to select the operating mode (Comfort or Economy) or
8) Press
+ or to set the time in steps of 15
minutes for the selected mode.
9) Press Ok to save the time switch.
10) Repeat steps 5-9 for the other period if necessary or
11) Press Mode or wait for the program to exit automatically.
Factory default of 7-day time switch
Default value
Day/s Comfort mode Economy mode
Mo (1) – Fr (5)
6:00 – 8:00 hr 17:00 – 22:00 hr
22:00 – 6:00 hr 8:00 – 17:00 hr
Sa (6) – Su (7)
7:00 – 22:00 hr 22:00 – 7:00 hr
Does symbol appear on the display?
Symbol is displayed when the batteries are low. Replace them with 2 new alkaline batteries type AAA. Proceed as follows:
Get 2 new alkaline batteries type AAA
Remove the battery holder and then the batteries.
Insert the new batteries and, within 1.5 minutes, replace the battery holder
Ensure the exhausted batteries are disposed of correctly, in compliance with environmental requirements
Page 4
4/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Do you want to lock the buttons?
Mode Press and hold Mode for at least 7 seconds to
activate a button lock. Repeat to unlock. The unit operates normally when the buttons
are locked, but changes cannot be made.
Do you want to pair transmitter and receiver?
+
Learn
Mode
Please refer to the instructions that come with the receiver.
Do you want to change the parameters?
+ –
Ok
Mode
If you want to change control parameters, proceed as follows:
Press
+ and – simultaneously for 5
seconds
Release the buttons and parameter P01 is displayed on the bottom segment
Press
+ or – to scroll to the parameter
that needs to be changed
Press Ok to select the parameter
Press
+ or to change the value
Press Ok to confirm the changed value
Press Mode to exit the parameters
without saving or wait for the program to exit automatically
Parameter list
Parameter no.
Description Setting range
(default)
P01 Time format 1 = 24:00 hours
(default)
2 = 12:00 am/pm
P02 Selection of °C or
°F
1 = °C (default) 2 = °F
P03 Standard
temperature display
1 = room
temperature (default)
2 = setpoint
P04 Temperature
sensor calibration
-3…3 °C Step 0.5 °C (-6…6 °F, step 1 °F) Default: 0 °C
P06 Comfort setpoint
lock
0 = OFF (default) 1 = ON locked
according to setting in permanent temperature setpoint
P08 Economy setpoint
lock
0 = OFF (default) 1 = ON locked
according to setting in permanent temperature setpoint
P09 Buzzer 0 = OFF
1 = ON (default)
P10 Show frost
protection icon
0 = OFF (default) 1 = ON
P11 Time switch type
for Auto Timer
0 = individual days
(default) 1= all 7 days 2= 5-2 days
P12 Periodic pump run 0 = OFF (default)
1 = ON
P14 X1 external input 0 = no input (default)
1 = external sensor 2 = digital input
P15 Temperature
limitation
0 = OFF (default) 1 = ON
P16 Max. limitation
temperature for floor heating
35…60 °C, step 1 °C or
95…140 °F, step 1 °F Default: 55 °C
P17 Window contact
features
0 = normally open contact (default)
1 = normally closed
contact
P19 Sequential number
of room unit
0 = no display of
zone (RF off) 1 = zone number 1
(for standard RF) (default)
… 6 = zone number 6
P20 RF learn 0 = OFF (default)
1 = ON
P21 Scanning rate for
the capacitive buttons
Note: Shorter scanning rate means shorter battery life
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
P22 Reload factory
settings
0 = OFF (default) 1 = reload
P23 Software version
information
No adjustment possible
Loading...