1/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
s
The RDE100.1RF consists of a wireless room thermostat RDE100.1RF which operates in connection with an
RDE-MZ6 receiver. These units allow you to set the ideal room temperature at the time you want.
There are several switching patterns available that can be set to meet your individual needs.
1 Display
need to be replaced
Time of day
Frost protection (heating)
active
Afternoon: 12-hour format
Confirmation
View and set Auto Timer
degrees Fahrenheit
Comfort mode
Room temperature in
degrees Celsius
Economy mode
Button lock activated
Escape
setting
Heating On
Weekday and time of day
setting
Timer bar
Current room temperature
2 Change operating mode
3 Set
4 Ok
5 Decrease value
6 Increase value
7 Battery holder
RDE-MZ6
To be purchased separately
Do you want to set the time of day and the weekday?
Set
Ok
+
–
Mode
Proceed as follows:
• Press Set and select
• Press Ok and the time of day flashes for setting
• Press
+ or – to adjust the time of day
• Press Ok to confirm
• The weekday flashes; press
+ or – to select the desired day
• Press Ok to save the setting
• Press Mode to exit or wait for the program to exit automatically

2/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Are your rooms too warm/too cold?
+
–
Ok
Set
Mode
Press + or
– to increase or decrease the
room temperature setpoint in increments of
0.5 °C/1 °F. Proceed as follows:
• Press
+ or – to change the setpoint
temporarily.
This readjustment is reset as soon as
the operating mode changes
• Press Ok, Set or Mode to save the
setting or wait for the program to exit
automatically
• To lock the setpoints, use parameters
P06 and P08
Do you want to change the operating
mode?
Mode
!
The thermostat provides Comfort, Economy
and automatic mode. Changeover between
the operating modes can be made manually
by pressing Mode.
Comfort mode is the permanent (24 h)
selection of Comfort. Select this operating
mode to maintain Comfort temperature
permanently without any time switch. It is
used during occupancy periods, for
example.
Economy mode is the permanent (24 h)
selection of Economy. Select this operating
mode to maintain the Economy temperature
permanently without any time switch.
It is used during non-occupancy periods
(e.g. at night).
In Auto Timer mode, the operating
modes (Comfort, Economy) are changed
automatically according to the time switch
setting.
Note:
Frost protection is a function always active
in the background. As soon as the room
temperature falls below 5 ºC, the unit
automatically activates heating
.
Do you want to set permanent temperature
setpoints?
Set
Ok
+
–
Mode
!
• Press Set and select
• Press Ok to confirm
• Press Mode to select the operating
mode (Comfort or Economy)
• Press
+ or – to adjust the setpoint
permanently
• Press Ok to confirm
• Press Mode to exit or wait for a timeout
to exit automatically
Note:
This permanent setpoint is used during Auto
Timer mode.
Energy saving tips without loss of
comfort
• Select Auto Timer mode for the heating period, and
set the time switch according to your normal habits at
home
• Select Economy or Holiday mode for longer periods
of non-occupancy and the summer period
Do you want to set your Holiday mode?
Set
Ok
+
–
Mode
!
Use the Holiday mode to set the thermostat
to a constant room temperature while
absent.
• Press Set and select
• Press Ok to confirm
• Press
+ or – to adjust the temperature
setpoint
• Press Ok to confirm
• Press
+ or – to set the number of days
for holidays (0 = Holiday mode Off)
• Press Ok to save the setting
• When Holiday mode is activated, the
remaining days are displayed
Note:
If you press Mode while Holiday mode is active, the
function is deactivated and symbol
disappears.
If the Comfort and Economy setpoints are both
locked, the lowest locked setpoint is the Holiday
mode setpoint. You can adjust the setpoint from 5 ºC
up to the lowest locked setpoint
.
Do you want to enter your own time switch?
Option 1: Time switch with individual day settings
(P11=0)
Set
Ok
+
–
Mode
You can select Comfort or Economy mode
in steps of 15 minutes throughout the day.
The 0:00 to 24:00 hour time bar allows you
to set the operating mode for the selected
day(s).
Example:
Visible bars: Control to Comfort
temperature
Invisible bars: Control to Economy
temperature
When Auto Timer mode is enabled,
changeover between the operating modes is
automatic after the settings are saved.
Proceed as follows:
1) Press Set and select
.
2) Press Ok to confirm.
3) Time switch for Mon (1) is displayed.
4) Press
+ or – to select the weekday, from
Mon(1) to Sun(7).
5) Press Ok to confirm the selection and
initiate time programming.
During programming:
6) Press Mode to select the operating mode
(Comfort or Economy) or
7) Press
+ or – to set the time in steps of
15 minutes for the selected mode.
8) Press Ok to save the time switch.
9) Repeat steps 4-8 for all remaining days (if
required) or
10) Press Mode or wait for the program to
exit automatically.

3/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Option 2: Time switch with the same 7-day settings
(P11=1)
Set
Ok
+
–
Mode
You can set the time switch so that all settings
apply to the 7 weekdays.
Example:
Visible bars: Control to Comfort
temperature
Invisible bars: Control to Economy
temperature
Proceed as follows:
1) Set the parameter (P11=1). Please refer to
section "Do you want to change
parameters".
2) Press Set and select
.
3) Press Ok to confirm.
4) Time switch for Mon (1) - Sun (7) is
displayed.
5) Press Ok to initiate time programming.
During programming:
6) Press Mode to select the operating mode
(Comfort or Economy) or
7) Press
+ or – to set the time in steps of 15
minutes for the selected mode.
8) Press Ok to save the time switch.
9) Press Mode or wait for the program to exit
automatically.
Option 3: Time switch with 5-2-day settings
(P11=2)
Set
Ok
+
–
Mode
You can set Monday - Friday and Saturday Sunday at the same time.
Example:
Visible bars: Control to Comfort
temperature
Invisible bars: Control to Economy
temperature
Proceed as follows:
1) Set the parameter (P11=2). Please refer
to section "Do you want to change
parameters".
2) Press Set and select
.
3) Press Ok to confirm.
4) Time switch for Mon (1) – Fri (5) is
displayed.
5) Press
+ or – to select Mon (1) – Fri ( 5)
or Sat (6) - Sun (7).
6) Press Ok to confirm the selected period
and initiate time programming.
During programming:
7) Press Mode to select the operating mode
(Comfort or Economy) or
8) Press
+ or – to set the time in steps of 15
minutes for the selected mode.
9) Press Ok to save the time switch.
10) Repeat steps 5-9 for the other period if
necessary or
11) Press Mode or wait for the program to exit
automatically.
Factory default of 7-day time switch
Default
value
Day/s Comfort mode Economy mode
Mo (1) –
Fr (5)
6:00 – 8:00 hr
17:00 – 22:00 hr
22:00 – 6:00 hr
8:00 – 17:00 hr
Sa (6) –
Su (7)
7:00 – 22:00 hr 22:00 – 7:00 hr
Does symbol appear on the display?
Symbol is displayed when the batteries are low.
Replace them with 2 new alkaline batteries type AAA.
Proceed as follows:
• Get 2 new alkaline batteries type AAA
• Remove the battery holder and then the batteries.
Insert the new batteries and, within 1.5 minutes,
replace the battery holder
• Ensure the exhausted batteries are disposed of
correctly, in compliance with environmental
requirements

4/4 Operating Instructions CB1B1432en_01 / 2013-07-05 Siemens Building Technologies
Do you want to lock the buttons?
Mode Press and hold Mode for at least 7 seconds to
activate a button lock. Repeat to unlock.
The unit operates normally when the buttons
are locked, but changes cannot be made.
Do you want to pair transmitter and
receiver?
+
–
Learn
Mode
Please refer to the instructions that come with
the receiver.
Do you want to change the parameters?
+
–
Ok
Mode
If you want to change control parameters,
proceed as follows:
• Press
+ and – simultaneously for 5
seconds
• Release the buttons and parameter
P01 is displayed on the bottom
segment
• Press
+ or – to scroll to the parameter
that needs to be changed
• Press Ok to select the parameter
• Press
+ or – to change the value
• Press Ok to confirm the changed value
• Press Mode to exit the parameters
without saving or wait for the program
to exit automatically
Parameter list
Parameter
no.
Description Setting range
(default)
P01 Time format 1 = 24:00 hours
(default)
2 = 12:00 am/pm
P02 Selection of °C or
°F
1 = °C (default)
2 = °F
P03 Standard
temperature display
1 = room
temperature
(default)
2 = setpoint
P04 Temperature
sensor calibration
-3…3 °C
Step 0.5 °C
(-6…6 °F, step 1 °F)
Default: 0 °C
P06 Comfort setpoint
lock
0 = OFF (default)
1 = ON locked
according to setting
in permanent
temperature setpoint
P08 Economy setpoint
lock
0 = OFF (default)
1 = ON locked
according to setting
in permanent
temperature setpoint
P09 Buzzer 0 = OFF
1 = ON (default)
P10 Show frost
protection icon
0 = OFF (default)
1 = ON
P11 Time switch type
for Auto Timer
0 = individual days
(default)
1= all 7 days
2= 5-2 days
P12 Periodic pump run 0 = OFF (default)
1 = ON
P14 X1 external input 0 = no input (default)
1 = external sensor
2 = digital input
P15 Temperature
limitation
0 = OFF (default)
1 = ON
P16 Max. limitation
temperature for
floor heating
35…60 °C, step 1 °C
or
95…140 °F, step 1 °F
Default: 55 °C
P17 Window contact
features
0 = normally open
contact (default)
1 = normally closed
contact
P19 Sequential number
of room unit
0 = no display of
zone (RF off)
1 = zone number 1
(for standard RF)
(default)
…
6 = zone number 6
P20 RF learn 0 = OFF (default)
1 = ON
P21 Scanning rate for
the capacitive
buttons
Note: Shorter
scanning rate
means shorter
battery life
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
P22 Reload factory
settings
0 = OFF (default)
1 = reload
P23 Software version
information
No adjustment
possible