Siemens Personal Computer IPC427C User Manual

Product Data Sheet
SIMATIC IPC427C (bottom side), PROFIBUS version
SIMATIC IPC427C (bottom side), PROFINET version
SIMATIC IPC427C
© Siemens AG 2013
SIMATIC IPC427C (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration:
• Maintenance-free
• Intel Core2 Duo technology
Design
Basic design
• All-metal enclosure, resistant to vibrations and shocks, also with high electromagnetic compatibility
• Graphics onboard, on AGP bus: DVI-I: VGA (analog) and DVI (digital)
- CRT resolution: Up to 1920 x 1200 pixels / true color /
60 to 120 Hz
- DVI-D resolution: Up to 1920 x 1200 pixels / true color
• Optical drives can be connected externally via USB interface, not included in scope of supply
• Interfaces (accessible from one side):
- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)
- 4 x high-speed USB V2.0
- 1 x COM1 (RS232)
• Free slots (when using the expansion rack):
- Up to 3 x PCI104-Plus cards
• Isolated power supply: 24 V DC (19.2 to 28.8 V)
Design versions
• Processor:
- Intel Core2 Duo 1.2 GHz, 800 MHz FSB, SLC 3 MB
- Intel Core2 Solo 1.2 GHz, 800 MHz FSB, SLC 3 MB
- Intel Celeron M 1.2 GHz, 800 MHz FSB, SLC 1 MB
• Primary storage capacity of 1 GB to (2/4 GB optional), DDR3 SDRAM
• Fieldbus
- PROFINET onboard, 3 x RJ45, CP16116-compatible
- PROFIBUS DP/MPI on board, compatible with CP 5611
• Hardware expansion:
- Second RS232 interface (COM2) in expansion rack
• Drives:
- Solid-State Drive 50 GB High Endurance or 80 GB Stan-
dard, rugged alternative to hard disk
- FlashDrive (replaceable, accessible): 2 GB, 4 GB, 8 GB or
16 GB
- FlashDrive (internal, not accessible): 2 GB, 4 GB, 8 GB,
16 GB
- Hard disk serial ATA, 2.5"
• Pre installed operating systems:
- Windows XP Embedded Standard 2009
(successor to Windows XP Embedded)
- Windows XP Professional Multi-Language
- Windows 7 Ultimate MUI
- Windows Embedded Standard 7
All rights reserved SIMATIC IPC427C © Copyright Siemens AG 2013
1/5
Technical specifications Box PC SIMATIC IPC 427C
General features
© Siemens AG 2013
Drives
Design DIN rail or wall mounting, front upright
Processor • Intel Core2 Duo 1.2 GHz, 800 MHz
Chipset Intel GM45 / ICH9M
Main memory 1 GB, (2/4 GB) DDR3 SDRAM
Buffered SRAM 2 MB, of which 128 KB can be written
Free slots for expansions Up to 3 x PCI-104, 3 W per slot
Graphics • Integrated Intel GMAX4500 graphics
Operating system • Without
mounting, mounting position preferably horizontal, vertical possible
FSB, SLC 3 MB
• Intel Core2 Solo 1.2 GHz, 800 MHz FSB, SLC 3 MB
• Intel Celeron M 1.2 GHz, 800 MHz FSB, SLC 1 MB
within the buffer time
• 8 ... 512 MB shared graphics memory (managed dynamically)
• CRT resolution: 640 x 480 pixels up to max. 1920 x 1200 pixels at 32 bit colors
• DVI-D resolution: 640 x 480 pixels up to max. 1920 x 1200 pixels at 32 bit colors
• Windows XP Embedded Standard 2009 preinstalled, in combination with CF card of 2 GB or more, solid-state drive, or hard drive
• Windows XP Professional MUI (in combination with solid-state drive or hard drive; MUI: Multi Language User Interface)
• Windows 7 Ultimate MUI (in combina­tion with solid-state drive or hard drive; MUI: Multi Language User In­terface)
• Windows Embedded Standard 7 pre­installed, in combination with CF card of 4 GB or more, or solid-sate drive, or hard drive RMOS3 (can be ordered separately)
•Linux1) (project-specific, on request)
• Others on request project-specifically
Flash drive Optional; replaceable, accessible,
Solid-State Drive (SSD) Optional
Hard disk Optional
CD-ROM Via USB (not included in scope of
DVD-RW Via USB (not included in scope of
Diskette Via USB (not included in scope of
diagnosable
•2 GB
•4GB
•8GB
•16 GB
Optional; internal, not accessible, diagnosable
•2 GB
•4GB
•8GB
•16 GB
• 50 GB SATA, 2.5" in single-level cell (SLC) architecture (High Endurance), especially suitable for industrial appli­cations
• 80 GB SATA, 2.5" Standard
> 250 GB SATA
delivery)
delivery)
delivery)
Interfaces
PROFINET 3 x RJ45 (CP 1616-compatible,
PROFIBUS/MPI 12 Mbit/s (isolated, compatible to
Ethernet • 2 x 10/100/1000 Mbit/s (RJ 45)
optional)
CP 5611) optional
• Two independent Intel 82574L controllers (via PCI-Express)
• One controller with none-shared interrupt
• With teaming function
Power supply • 24 V DC (19.2 V ... 28.8 V)
• Isolated
• With buffering of temporary power failures: Max. 10 ms at 0.85% rated voltage
• Line side switch
• With power failure indication by means of Power Fail signa
l
USB V2.0/High Speed: 4 x
Serial COM1 (V.24)
DVI-I 1 x DVI-I (includes DVI-D and VGA)
Keyboard Via USB (not included in scope of
Mouse Via USB (not included in scope of
COM2 (V.24) optional (in expansion frame)
delivery)
delivery)
All rights reserved SIMATIC IPC427C © Copyright Siemens AG 2013
2/5
© Siemens AG 2013
Monitoring functions
Temperature • Processor temperature
• Motherboard
• Messages can be evaluated by the
application program
Watchdog • Monitoring of program execution
• Monitoring time can be parameter-
ized in software
• Can be parameterized for a fault or
restart
• Messages can be evaluated by the
application program.
Monitoring functions via the network
•DiagBase
• SIMATIC PC DiagMonitor Remote monitoring capability for:
• Watchdog
•Temperature
• Mass memory monitoring (SMART)
• System / Ethernet monitoring
(Heartbeat)
• Runtime meter Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC soft-
ware
• Configuration of client/server archi-
tectures
• Layout of log files
Ambient conditions
Shock loading during operation
Electromagnetic compatibility (EMC)
• Emitted interference EN 55022 Class B
• Interference immunity, burst
• Interference immunity, surge
• ESD interference immunity
Devices without hard disk:
• Requirements according to: IEC 61131-2
• Tested according to: IEC 60068-2-27, Test E a
• Module/rack: 150 m/s2, power-up, 11 ms shock duration
Devices with hard disk: Wall mounting
• Requirements according to: IEC 61131-2
• Tested according to: IEC 60068-2-27, Test E a
• Devices with drive: 50 m/s2, power­up, 30 ms shock duration
EN 61000-6-2 or IEC 61131-2:
• 2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical
- Tested acc. to IEC 61000-4-5
1 kV to IEC 61000-4-5; symmetrical 2 kV to IEC 61000-4-5; asymmetrical
According to NAMUR Recommenda­tion NE 21 and EN 61000-6-2:
• 6 kV contact discharge - Tested acc. to IEC 61000-4-2
• 8 kV air discharge - Tested acc. to IEC 61000-4-2
Degree of protection to EN 60529 (front/rear)
Vibration load during operation
IP20
Devices without hard disk:
• Requirements according to: IEC 61131-2
• Tested according to: IEC 60068-2-6, Test F c
• Devices without drive:
- 5-9 Hz, 3.5 mm deviation, 10x /axis,
1 octave/min
- 9-150 Hz, 9.8 m/s2, 10x /axis,
1 octave/min
Devices with hard disk: Wall mounting
• Requirements according to: IEC 61131-2
• Tested according to: IEC 60068-2-6, Test F c
• 10 ... 58 Hz, 0.0375 mm deviation, 10x /axis, 1 octave/min
• 58 ... 200 Hz, 4.9 m/s2, 10x /axis, 1 octave/min
• Immunity to high radio frequency interference
• Immunity to high-fre­quency current feed
• Immunity to magnetic fields
Ambient temperature dur­ing operation
Moist heat • With CompactFlash card/SSD: 95 %
According to EN 61000-6-2 or IEC 61131-2:
• Interference immunity 80 ... 1000 MHz: 10 V/m with 80% AM (1 kHz); tested acc. to IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50% pulse modulation; tested according to IEC 61000-4-3
Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2:
• 10 kHz ... 80 MHz: 10 V with 80% AM (1 kHz) tested acc. to IEC 61000-4-6
Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2:
50/60 Hz; 100 A/m rms value - tested acc. to IEC 61000-4-8
• 0 ... 55 ºC with flash drive/SSD (horizontal; preferred mounting position; with derating)
• 0 ... 50 ºC with flash drive/SSD (horizontal; preferred mounting position; maximum configuration)
• 0 ... 50 ºC with flash drive/SSD (vertical)
• 5 ... 40 ºC with hard disk (horizontal and vertical)
• With hard drive 80%
SIMATIC IPC427C All rights reserved
3/5
© Copyright Siemens AG 2013
© Siemens AG 2013
System-tested SIMATIC Industrial Software
WinAC RTX (F), WinCC flexible, WinCC (SCADA as of V7.0), WinCC RT Advanced and Professional
Approvals
Marine approval Only for configurations
with CompactFlash or SSD memory
Safety regulations • IEC 61131-2
Approvals UL508, UL60950, cULus
• GL - Germanische Lloyd
• BV - Bureau Veritias
• LR - Lloyds Register of Shipping
• ABS - American Bureau of Shipping
• DNV - Det Norske Veritas
• NKK - Nippon Kaiji Kyokai
• IEC 61010-1
• EN 60950-1
CE mark • EC Directive 89/336/EEC
Dimensions and weights
Equipment dimensions (in mm)
Weight, approx. 2 kg
1)
Suitable for specific LINUX versions in accordance with the specifica-
tions of the Siemens manufacturer’s declaration "Suitable for LINUX", see http://www.siemens.de/simatic-pc/geeignet-fuer-linux (LINUX is a trademark of Linus Torvald).
(EMC Directive)
• Use in industry:
- Emitted interference: EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas, business and trade environments as well as in workshops:
- Emitted interference: EN 61000-6-3
- Noise immunity: EN 61000-6-1
• Width x height: 262 x 134
• Depth of basic unit: 47
• Depth of basic unit above rail: 50
• Additional depth per expansion (1-3): 17 each
Dimensional drawings (dimensions in mm)
262
133
138
46.5
*B67B;;B
52,5
97,5
262
138
G_ST80_XX_00456
All rights reserved SIMATIC IPC427C © Copyright Siemens AG 2013
4/5
© Siemens AG 2013
SIMATIC IPC – the more Industrial PC
More information on SIMATIC IPC is available at: www.siemens.com/simatic-ipc
A current overview of the configurations is provided by the SIMATIC IPC Online-Konfigurator:
In-depth information is available in the SIMATIC manuals: www.siemens.com/simatic-doku
Information material for download:
Technical documentation is available in our Service& Support portal:
Your personal contact partner is listed at: www.siemens.com/automation/partner
Electronic ordering via the Internet with the Mall: www.siemens.com/industrymall
Additional information on PC-based Automation with SIMATIC is available under:
Additional information on the TIA Portal: www.siemens.com/tia-portal
Additional information on SIMATIC Safety Integrated: www.siemens.com/f-cpu
Online Service Tool PED – for fast information on the equipment of your SIMATIC PC and the management of your field invento­ry:
www.siemens.com/ipc-configurator
www.siemens.com/simatic/printmaterial
www.siemens.com/automation/support
www.siemens.com/pc-based-automation
www.siemens.com/ped
SIMATIC IPC427C All rights reserved
5/5
© Copyright Siemens AG 2013
Loading...