Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of
others, and to protect the product and the connected equipment. These warning notices are
accompanied by a clarification of the level of caution to be observed.
Qualified Personnel: This device/system may only be set up and operated in conjunction with this
manual. Qualified personnel are only authorized to install and operate this equipment in accordance with
established safety practices and standards.
Unit Repair and Excluded Liability:
•The user is responsible for all changes and repairs made to the device by the user or the user’s
agent.
• All new components are to be provided by Siemens Milltronics Process Instruments Inc.
• Restrict repair to faulty components only.
• Do not reuse faulty components.
Warning: This product can only function properly and safely if it is correctly transported, stored,
installed, set up, operated, and maintained.
Note: Always use product in accordance with specifications.
Copyright Siemens Milltronics Process
Disclaimer of Liability
Instruments Inc. 2006. All Rights Reserved
This document is available in bound version and in
electronic version. We encourage users to purchase
authorized bound manuals, or to view electronic versions
as designed and authored by Siemens Milltronics Process
Instruments Inc. Siemens Milltronics Process Instruments
Inc. will not be responsible for the contents of partial or
whole reproductions of either bound or electronic
versions.
While we have verified the contents of this
manual for agreement with the
instrumentation described, variations
remain possible. Thus we cannot
guarantee full agreement. The contents of
this manual are regularly reviewed and
corrections are included in subsequent
editions. We welcome all suggestions for
improvement.
Technical data subject to change.
MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments Inc.
Contact SMPI Technical Publications at the following address:
Technical Publications
Siemens Milltronics Process Instruments Inc.
1954 Technology Drive, P.O. Box 4225
Peterborough, Ontario, Canada, K9J 7B1
Email: techpubs.smpi@siemens.com
•For a selection of Siemens Milltronics level measurement manuals, go to:
www. siemens.com/processautomation. Under Process Instrumentation, select
Measurement
•For a selection of Siemens Milltronics weighing manuals, go to:
www. siemens.com/processautomation. Under Weighing Technology, select
Weighing Systems
and then go to the manual archive listed under the product family.
and then go to the manual archive listed under the product family.
The Manual ...............................................................................................................................................1
Cleaning and Maintenance .............................................................................................12
i
Page 4
ii
Page 5
Safety Notes
Special attention must be paid to warnings and notes highlighted from the rest of the text
by grey boxes.
1
WARNING1: means that failure to observe the necessary precautions
can result in death, serious injury, and/or considerable material damage
Note:
means important information about the product or that part of the operating
manual.
Safety marking symbols
In manualOn productDescription
Protective Conductor Terminal
Both direct and alternating current
The Manual
Notes:
• Please follow the installation and operating procedures for a quick, trouble-free
installation and to ensure the maximum accuracy and reliability of your Millpulse 600.
This manual will help you set up your Millpulse 60 0 for optimum performance. We always
welcome suggestions and comments about manual content, design, and accessibility.
Please direct your comments to techpubs.smpi@siemens.com
For other Siemens Milltronics process protection manuals, go to:
www.siemens.com/processprotection
.
.
WARNING: Millpulse 600 is to be used on ly in th e ma n ner ou tl in e d in
this manual, otherwise protection provided by the equipment may be
impaired.
1.
This warning symbol is used when there is no corresponding caution symbol on the
product.
Milltronics Millpulse 600 is a heavy-duty 2-wire motion sensor that provides a solid state
switch output to a PLC
reciprocating, or conveying equipment.
Milltronics Millpulse 600 has a circuit card and magnet assembly potted in the probe
body and comes complete with mounting flange and locknut. Milltronics Millpulse 60 0 is
connected in series with the PLC input (or other load) and acts as a switch, opening and
closing as the ferrous targets of the machinery being monitored pass in front of the probe.
1
. It is used primarily for monitoring the speed of rotating,
1.
Milltronics Millpulse 600 is designed to work with Programmable Logic Controllers (PLC) with input characteristics compatible with the electrical portion of the
CENELEC 50040/36/37/38 standards for two wire proximity sensors.
WARNING: The probe is highly magnetic. Keep it away from
magnetosensitive materials such as computer discs an d aud io or
video tapes.
Environment
Milltronics Millpulse 600 should be mounted in an area that is within the temperature
range specified and that is suitable to the housing rating and materials. The cap should
be accessible to allow for wiring and viewing if the status display LED is used.
Milltronics Millpulse 600 should be mounted using the supplied mounting flange, onto a
vibration-free structure. The gap between the face of the Milltronics Millpulse 600 and
the target should be sufficient so there is no danger of the target damaging the unit. Refer
to the chart in the
respect to target velocity.
Operation
Note: In climates where direct sunlight may cause the Milltronics Millpulse 600
temperature to rise above the specified limit, shade the unit by installing a sun shield.
Wiring
Note: All wiring must be done by qualified personnel in accordance with all
governing regulations.
section (page 8) for the maximum allowable gap with
Where possible, the probe should be mounted such that the conduit entry is pointing
down to avoid accumulation of condensation in the casing. Where wiring must be run in
conduit, the use of flexible conduit is suggested for easier removal or adjustment of the
probe.
It is advisable to keep the Milltronics Millpulse 600 away from high voltage or current
runs, contactors and SCR drives.
WARNING: Do not connect Milltronics Mill pu l s e 6 00 direc t ly to
supply.
Ensure that the switching current of the PLC input is above the residual current of the
Milltronics Millpulse 600 and that the load resistance presented by the PLC input is low
enough to ensure that the minimum operating current of the Milltronics Millpulse 600 is
exceeded (see Loading graph). If your PLC does not meet the requirements, a resistor
across the PLC inputs can be used to increase the switching current.
Note:
• The protective earth terminal indicated by must be connected to reliable
ground.
• The protective earth terminal indicated by must be connected to reliable
ground.
• All wiring must be done by qualified personnel in accordance with all governing
regulations.
• The equipment must be protected by a 15A fuse or circuit breaker in the building
installation.
• A circuit breaker or switch in the building installation, marked as the disconnect
switch, shall be in close proximity to the equipment and within easy reach of the
operator.
WARNING : All f ield wir ing m ust h ave in sulati on su itable for a t leas t
135 V.
Milltronics Millpulse 600 works on the principle of Faraday’s Laws of Electromagnetic
Induction. When a ferromagnetic object (target) enters the probe’s permanent magnetic
field, it distorts the flux causing it to cut the coil windings, thereby generating a voltage.
This voltage is proportional to the speed at which the ferrous target passes through the
flux and is inversely proportional to the square of the distance between the target and
the probe.
Square profile targets work better than round because they present a sharper transition
in ferrous mass. Minimizing the gap is more effective than an increase in target size
beyond 5 cm x 5 cm x 2.5 cm (2” x 2” x 1”), except at very low velocities.
The voltage generated from the probe coil is fed to a processing circuit. The processing
circuit controls a semiconductor switch that opens and closes in response to the
incoming pulses. The switch is normally open (LED off) and closes when a pulse is
generated (LED on). The switch duration times are held to a minimum of 50 msec to give
the PLC sufficient time to read the switch states.
The amplifier has been tuned for a response typical to the range of speed encountered in
industrial applications. This response governs the relationship between target speed and
probe to target gap, as demonstrated in the following chart. The resultant curves indicate
the maximum velocity is about 33 cm/sec. (65 ft/min), and with a velocity of 1 cm/sec.
(2 ft/min), a maximum gap of 3.1 cm (1.25”) is possible.
2"x1"x2"
ferrous target
‘A’
2"x2"x1"
ferrous target
‘B’
2"x1"x1"
ferrous target
‘C’
This graph was plotted from tests using four ferrous blocks set equidistant on a 41 cm
(16”) diameter circle on a non-ferrous disc.
Milltronics Millpulse 600
with supplied flange and
locknut
conveyor troughing
bracket
window
plate
Install a non-ferrous window for screw conveyors with troughing over 3 mm (0.125”) thick
or for high temperature applications. The dimensions shown for the plate, window, and
bracket are the minimum recommended. Use series 300 stainless steel, brass, or
aluminum. Milltronics Millpulse 60 0 must not touch the plate if temperatures are in
excess of 60 °C (140 °F).