Siemens MICROMASTER 4 Installation Instructions Manual

Page 1
1
2
EMC Filter - Installation Instructions
L1
L2
L3
L
N
Ground
Issue A7
May also be used with inverters when specified in the SINAMICS Catalog D11.1.
MICROMASTER 4 Frame Size A to C
CT
VT
Catalog DA
51.2
HO
LO
Catalog D 11.1
B
B
A
A
C
C
FSA
FSB FSC
D
E
F
FSB FSC
J
I
G
H
L
K
I
J
H
L
FSA
FSB FSC
1
2
Ground
Gland Plate (optional)
)
mm(
sn
oisnemiD
gnixiF
)mm(
snoisnemiD
ll
a
r
evO
thgieW
scitsiretcarah
C l
acir
tcelE
noitacifitnedI retliF
Terminals Cable Cross Section
Filter Filter Filter + Inverter Inverter Filter
Tightening
Torque
min max
Footprint Side Mount
MFLB
Frame
Size (FS)
Voltage
[V]
Current
[A]
Phase
kg
A B C D E F G H
Fixing
Size
I J K L
Fixing
Size
Nm lbf.in mm
2
AWG mm2 AWG
6SE6400-2FA00-6AD0
A 200 - 480 6 3 0.5
6SE6400-2FB00-6AD0 A 200 - 480 6 3 0.5
6SE6400-2FL01-0AB0 A 200 - 240 10 1 0.5
6SE6400-2FS01-0AB0 A 200 - 240 10 1 0.5
200 73 43.5 200 73 192.5 – 160 M4 (2) 56 187 – 187
Foot­print:
M5 (4)
Side Mount: M5 (2)
1.1 5 - 7 1 17 2.5 14
6SE6400-2FA01-4BC0 B 200 - 240 14 3 1
6SE6400-2FB01-4BC0 B 200 - 240 14 3 1
6SE6400-2FL02-6BB0 *) B 200 - 240 26 1 1
6SE6400-2FS02-6BB0 B 200 - 240 26 1 1
6SE6400-2FS01-6BD0 B 380 - 480 16 3 1
6SE6400-2FB01-4BC0 B 200 - 480 14 3 1
213 149 50.5 213 149 222.5 138 174 M4 (4) 120 200 24 200 M5 (4)
1.5 13.3 1.5 16 6 10
6SE6400-2FS03-5CB0 C 200 - 240 35 1 1.5
6SE6400-2FS03-8CD0 C 200 - 480 38 3 1.5
245 185 55 245 185 250 174 204 M4 (4) 156 232 38 232 M5 (4) 2.25 20 2.5 14 10 8
*) MICROMASTER 4 : The DC+ and DC- marked wires have to be connected to the appropriate terminals of the inverter. SINAMICS G110 : The DC+ and DC- marked wires are volt-free connections and can be taped up, or cut off.
Page 2
OPTIONS COMBINATIONS EXAMPLES
2
MAINS INPUT
OUTPUT CHOKE
EMC FILTER
MOTOR CABLE
FILTER CABLE
OUTPUT CHOKE CABLE
EMC FILTER
OUTPUT CHOKE
MOTOR CABLE
MAINS
INPUT CHOKE (REVERSED)
OUTPUT CHOKE CABLE
INPUT CHOKE CABLE
FILTER CABLE
Recommended Combinations
Footprint Mounted on side Inverter
Frame Size
Position 1 Position 2 Line-side
components (left)
Output-side components (right)
Example
EMC Line – Output and/or Brake
1
EMC or Line
Output or LC
– Brake
2
A, B
EMC or Line
Brake –
EMC Line – Output and/or Brake
1
EMC or Line
Output – Brake
2
C
LC – EMC and/or Line Brake
EMC = EMC filter Line = Lin e commutating (Input) choke LC = LC filter
Output = O utput choke Brake = Braking resistor
MAINS INPUT
FILTER CABLE
EMC FILTER
INPUT CHOKE (REVERSED)
FILTER CABLE
MAINS
EMC FILTER
1