Siemens MI290A User Manual

Page 1
Guarto Multifunctional Security System
Maintenance Info MI290a MP3 - Service Release SR1
Building Technologies
Fire Safety & Security Products
Page 2
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. Sous réserve de modifications techniques et de la disponibilité. © 2009 Copyright by Siemens Switzerland Ltd
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Nous nous réservons tous les droits sur ce document, ainsi que sur l'objet y figurant. La partie recevant ce document reconnaît ces droits et elle s'engage à ne pas le rendre accessible à des tiers, même partiellement, sans notre autorisation écrite préalable et à ne pas l'employer à des fins autres que celles pour lesquelles il lui a été remis.
Page 3
Maintenance Info MI290a: Guarto MP3 SR1
1 Maintenance Info MI290a: Guarto MP3 SR1
The first edition of MP3 for Guarto was released in January 2003. See related Up­data sheet UPe128. This release MP3 SR1 became available in January 2004.
MP3 is the common version for networked applications or standalone respectively.
This service release provides improved stability for the Guarto application as a whole and for the communication to external devices on the LON bus as well as for the communication with the management station. Further, some bugs have been fixed.
1.1 Actual Compatibility
Guarto MP3 SR1 Version Memories Remark/Checksum
Actual compatibility
Software Tool
Maintenance System SWE6 Release MP3 Maintenance System SWE6 Release MP3 SR1 Standard Text Editor SWU6 Release MP3
Master Card E3X130
Control Unit Program Empty EPROM: Type 27C4001
RAMs RAM: 512kx8
LON Adapter K3I070
Empty EPROM: Type 27C256
Terminal CT6M
Index bb does not support
Index bc with new LCD-
Terminal CT6C
Firmware Empty EPROM: Type 27C512
Door Module DCU601
Firmware Empty EPROM: Type 27C512
PAL $457E
Dialer (IK601) K3D030
Firmware Empty EPROM: Type 27C512
V5.0 V5.0a V4.4
CCD005.02
BKD002.02
V1.2
V2.0
CTD001.04
CFD003.03
PFD002.00
CK6_V16
Tab. 1 Compatibility
= part. No. 476 362 0001
= part no. 484 794
= part. No. 390 477
= part. No. 417 745
= part. No. 417 745
= part. No. 417 745
$5200 /odd, $8E00 /even Bridges EPROM: X11, Y12 Bridges RAM: X10
$BC00
Cyrillic
Controller for Cyrillic
$B4D6
$7BD6
$DEC8
Building Technologies MI290a.doc Fire Safety & Security Products 01.2009
3
Page 4
Maintenance Info MI290a: Guarto MP3 SR1
1.2 Fixed Application Problems
A CT6C configured for ‘Section operation’ does not crash the system anymore. The internal workspace for the terminal application is now increased so that the function has enough memory available.
A wrong indication “not done” for the execution of a command has been eliminated. This was just indicated for a Section with Exit-Route when it was switched on, in case the configuration did allow switching off/on the sensors.
For the private devices CT6C and DCU6 on the LON bus, the communication has been enhanced. Now the supervision is stable so that random connection tamper messages will be avoided.
1.3 Improvements for Management Station
The stability of the communication is improved for the connection of management stations. In fact, a correction in the MM8001 allows now to connect two such sta­tions with Guarto.
New properties are supported in the communication model, which were added in the application of MP3. They are now available on the interface, but have not been added to the exported data in the profiles (due to incompatibility in import).
z ‘Door’ object for access control
doorOpen a door is currently open doorUnlocked a door is currently released
z ‘Area’ object
initialPINs user(s) have not yet changed the default PIN inhibitionTimeNotActive
z ‘Terminal’ object
operationFree a terminal is enabled for operation
e.g. only by key (without a user PIN)
z ‘PowerSupply’ object
tamperEmergencyPower possible attack by running out of power faulty indicates a problem from the attached ADI
(MBus addressing unit)
1.4 Known Problems
Guarto: Communication with management stations:
The protection for the time synchronization via network is too restrictive. There is
currently no way for correcting errors from remote (e.g. wrong daylight saving time). Local access is necessary to put CS6 in Service-Mode.
SWE6-Tool: Configuration and data export:
The dialogues are missing in the Area for setting the delay times of the remote
transmission of ‘Security-jeopardizing-faults’ and ‘Major-fault’ (default = 120s!).
The Profile-Generator does not put virtual Sections (without Zones) into the pro-
files. Æ Workaround: attach a dummy Zone (linked to ADI) getting both entries.
Mind the improved SWE6 tool V5.0a which became available in March 2005.
4 Building Technologies MI290a.doc
Fire Safety & Security Products 01.2009
Page 5
Maintenance Info MI290a: Guarto MP3 SR1
Building Technologies MI290a.doc Fire Safety & Security Products 01.2009