Siemens Low-Voltage Power Distribution Installation Manual

© Siemens 2020
Catalog Extract LV 10
Edition 04/2020
SENTRON • SIVACON • ALPHA
Low-Voltage Power Distribution and Electrical Installation Technology
Fuse Systems
siemens.com/lowvoltage
© Siemens 2020
Making sure power makes its way
Consistent, safe and intelligent low-voltage power distribution and electrical installation technology
Whether industries, infrastructures or buildings: Each environment depends on a reliable power supply.
Which is why products and systems featuring maximum safety and optimum
efciency are in demand. This comprehensive portfolio for low-voltage power
distribution and electrical installation technology covers every requirement – from the switchboard to the socket outlet.
We are there when you need us
Your personal contact can be found at
www.siemens.com/lowvoltage/contact
Catalog LV 10 · 04/2020
You will nd the latest edition and all future editions
in the Siemens Industry Online Support at
www.siemens.com/lowvoltage/catalogs
Refer to the Industry Mall for current prices
www.siemens.com/industrymall
The products and systems listed in this catalog are developed and manufactured using a certied quality management system in accordance with DIN EN ISO 9001:2008.
Technical data The technical specications are for general information purposes only. Always heed the operating instructions and notices on individual products during assembly, operation and maintenance.
All illustrations are not binding.
© Siemens 2020
© Siemens 2020
SENTRON · SIVACON · ALPHA
Low-Voltage Power Distribution and Electrical Installation Technology
Protecting
Protecting, Switching and Isolating
Switching and Isolating
Measuring and Monitoring
Introduction I/2
Air Circuit Breakers 1/1
Molded Case Circuit Breakers 2/1
Miniature Circuit Breakers 3/1
Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) 4/1
Switching Devices 5/1
Overvoltage Protection Devices 6/1
Fuse Systems 7/1
Switch Disconnectors 8/1
Transfer Switching Equipment and Load Transfer Switches 9/1
Measuring Devices, Power Monitoring and Digitalization Solutions 10/1
I
1
2
3
4
5
6
7
8
9
10
Distribution
Monitoring Devices 11/1
Transformers, Power Supply Units and Socket Outlets 12/1
Busbar Systems 13/1
Terminal Blocks 14/1
Power Distribution Boards, Motor Control Centers and Distribution Boards 15/1
Busbar Trunking Systems 16/1
System Cubicles, System Lighting and System Air-Conditioning 17/1
Appendix A/1
11
12
13
14
15
16
17
A
Fuse Systems
© Siemens 2020
Mandatory basic protection in electrical installations
Overcurrents in electrical installations occur as a result of excessive load or short-circuits and
can cause serious accidents, res and nancial
damage. Appropriate protection devices have therefore been mandatory ever since electricity
was rst harnessed to power equipment. As
a pioneer in fuse systems, we offer you the complete range of devices for the protection of cables as well as electrical devices and installations in the event of overloads and short­circuits.
Fuses are capable of safely switching off circuits as soon as an overload or short-circuit occurs. This prevents damage to electrical equipment or
extended power failures. Specic variants of fuse
systems are used for different applications.
Among other things, our fuses are used for protecting cables and lines, switching devices and semiconductors as well as in photovoltaics and wind power.

Fuse Systems

All the information you need 7/2
System overview 7/4
Overview of fuse systems 7/6
Fuse holders and bases 7/8
© Siemens 2020
Fuse Systems
Overview 7/8
MINIZED fuse switch disconnectors 7/12
MINIZED switch disconnectors 7/13
NEOZED bus-mounting switch disconnectors 7/14
NEOZED fuse bases 7/16
DIAZED fuse bases 7/18
Bus-mounting bases for 8US busbar systems 7/20
Photovoltaic cumulative fuse bases 7/21
LV HRC fuse bases 7/22
Cylindrical fuse holders 7/24
Fuse holders and bases for SITOR semiconductor fuses 7/25
Photovoltaic cylindrical fuse holders 7/26
Class J fuse holders 7/27
Class CC fuse holders 7/28
Fuse links 7/30
Overview 7/30
NEOZED fuse links 7/32
DIAZED fuse links 7/33
SILIZED fuse links 7/34
Photovoltaic cumulative fuse links 7/35
LV HRC fuse links 7/36
Cylindrical fuse links 7/41
7
SITOR semiconductor fuse links (LV HRC design) 7/42
SITOR semiconductor fuses (cylindrical fuse design) 7/59
Photovoltaic cylindrical fuse links 7/64
Class CC fuse links 7/65
Accessories 7/66
Busbars 7/66
LV HRC signal detectors, electronic fuse monitoring 7/70
Siemens LV 10 · 04/2020
7/1
Fuse Systems
|

All the information you need

© Siemens 2020
A multitude of additional information ... ... can be found in our online services
Information + ordering
All the important things at a glance
Information to get you started
For information about fuse systems, please visit our website
www.siemens.com/fuses
Siemens YouTube channel
Our video range
• Siemens fuse systems
bit.ly/2kWaepz
Everything you need for your order
Contact persons in your region
Refer to the Industry Mall for an overview of your
We are there when you need us
7
You can nd your local contacts at
www.siemens.com/lowvoltage/contact
Your product in detail
The Siemens Industry Online Support portal provides comprehensive information
www.siemens.com/lowvoltage/product-support
• Technology primer – Fuse systems (109482303)
products
• Fuse systems sie.ag/2kW3pnU
Direct forwarding to the individual products in the Industry Mall by clicking on the Article No. in the catalog or by entering this web address incl. Article No.
www.siemens.com/product?Article No.
Configurators
Exactly the right SITOR semicon-
The relevant tender specications can be found at
www.siemens.com/lowvoltage/tenderspecications
Use our conversion tool for quick and easy conversion to Siemens products www.siemens.com/conversion-tool
ductor fuse for your application
The congurator reduces the time and effort required in
the planning and ordering process, and allows for indivi-
dual adaptations. Congure your SITOR semiconductor
fuse at
www.siemens.com/lowvoltage/sitor-congurator
7/2
Siemens LV 10 · 04/2020
Commissioning + operation
© Siemens 2020
All the information you need
|
Fuse Systems
Your product in detail
The Siemens Industry Online Support portal provides detailed technical information
www.siemens.com/lowvoltage/product-support
• Operating instructions
• Characteristic curves
Certicates
Engineering data for CAD or CAE systems are available in the CAx Download Manager at
www.siemens.com/lowvoltage/cax
Manuals
Manuals are available for downloading in Siemens Industry Online Support at
www.siemens.com/lowvoltage/manuals
Conguration manual – Fuse systems
(45314810)
• Planning manual – Planning with SIVACON 8PS
(109478425)
The fast track to the experts
Competent expert advice on technical questions with a wide range of demand-optimized services for all our products and systems.
Assistance with technical queries is provided at
www.siemens.com/lowvoltage/support-request
We offer a comprehensive portfolio of services. You can nd your local contacts at
www.siemens.com/lowvoltage/contact
You can nd further information on services at
www.siemens.com/service-catalog
Technical overview – Fuse systems
The fast way to get you to our online services
This page provides you with comprehensive information and links on fuse systems
www.siemens.com/lowvoltage/product-support (109769085)
Siemens LV 10 · 04/2020
7/3
Fuse Systems
|

System overview

System overview
Fuse holders and bases
IEC fuse holders and bases
© Siemens 2020
MINIZED NEOZED DIAZED Bus-mounting bases
for busbars
Photovoltaic cumulative fuses
IEC/UL fuse holders and bases
7
LV HRC fuses Cylindrical
fuses
SITOR semiconductor fuses (LV HRC design)
SITOR semiconductor fuses (cylindrical fuse design)
Photovoltaic cylindrical fuses
UL fuse holders and bases
Class CC Class J
Accessories for fuse holders and bases
Covers Screw caps Adapter sleeves Isolating blades LV HRC signal detectors
Busbars and accessories
Can be cut Terminals Touch protection End caps
Note:
You will nd a detailed range of accessories with the basic units.
7/4
Siemens LV 10 · 04/2020
Fuse links
IEC fuse links
© Siemens 2020
System overview
|
Fuse Systems
NEOZED DIAZED LV HRC Cylindrical
fuses
IEC/UL fuse links
SITOR semiconductor fuses (LV HRC design)
SITOR semiconductor fuses (cylindrical fuse design)
UL fuse links
Class CC
Note:
You will nd a detailed range of accessories with the basic units.
SILIZED Photovoltaic
cumulative fuses
Photovoltaic cylindrical fuses
7
Siemens LV 10 · 04/2020
7/5
Fuse Systems
|

Overview of fuse systems

© Siemens 2020
Overview of fuse systems according to IEC
Fuse links Overview, see page 7/30
Standard Rated current I Voltage Un (AC) Voltage Un (DC)
Design / application
Selection according to
7
protection task
Cables and lines, general (gG)
Motor protection (aM)
Power semiconductor (aR, gR, gS)
Photovoltaic protection (gPV)
Battery protection (aR, gR, gBAT)
More information
n
Type
IEC IEC IEC IEC IEC / UL IEC / UL IEC UL
2 … 100 A 2 … 100 A 2 1250 A 0.5 100 A 2 2400 A 1 125 A 2 630 A 0.5 …30 A
400 V 500 … 750 V 400 690 V 400 690 V 500 2500 V 600 1500 V 600 V
250 V 500 … 750 V 250 400 V 440 3000 V 250 1000 V 1000 1500 V 150 … 300 V
NEOZED / SILIZED DIAZED / SILIZED LV HRC Cylindrical SITOR LV HRC SITOR cylindrical Photovoltaic Class CC
5SE 5SA, 5SB, 5SC, 5SD 3NA, 3ND 3NW6, 3NW8 3NE, 3NC 3NC10 3NE…, 3NW… 3NW1, 3NW2, 3NW3
See page 7/32 See page 7/34
See page 7/33 See page 7/34
Fuse holders and bases
For protection tasks Overview, see page 7/8
Floor
xation
Fuse bases 5SG IEC See page 7/12
5SF IEC See page 7/18
3NH IEC / UL See page 7/22
3NH7 IEC See page 7/22
3NW7 IEC / UL See page 7/24
3NC.. IEC / UL See page 7/25
3NW7...-4 IEC See page 7/26
Standard mounting rail
Busbar Type Stand-
ard
More information
For protection and switching tasks System overview, see page 8/80, 8/116
Floor
xation
Fuse switch disconnectors 3NP1 IEC / UL See page 8/80
3NP5 IEC / UL See page 8/94
5SG7 IEC See page 8/144
3NJ4 IEC See page 8/98
Switch disconnector with fuse 3KF LV HRC IEC See page 8/116 (■)
3KF SITOR IEC / UL See page 8/116
3NJ62 IEC See page 8/132
7/6
Siemens LV 10 · 04/2020
Standard mounting rail
Busbar Type Stand-
ard
More information
System overview, page 7/4
© Siemens 2020
Overview of fuse systems
|
Fuse Systems
See page 7/36 See page 7/41 See page 7/42 See page 7/59 See page 7/35
See page 7/64
7
See page 7/65
System overview, page 7/4
Siemens LV 10 · 04/2020
7/7
Fuse Systems
|

Fuse holders and bases

Overview of fuse holders, bases and D0 fuse switching devices
IEC IEC
© Siemens 2020
MINIZED
switch discon-
nectors
MINIZED fuse
switch discon-
nectors
NEOZED fuse bases NEOZED
comfort
bases
NEOZED
fuse bases
DIAZED fuse
bases
Basic data
Size D02 D01 D01 D02 D03 D01, D02 D01, D02 NDz, DII, DIII 8 × 32 mm 22 × 58 mm 000/
Variant 5SG71 5SG76 5SG15
7
Standards
Standards DIN VDE 0638;
Approvals UL File number E171267 KEMA; UL le number E171267-IZLT2 Approvals
Technical specications AC
Rated voltage U
Rated insulation voltage V AC 500 690 Short-circuit strength kA AC 50 50 50 50 50 50 50 50 20 100 Rated current I
Rated impulse withstand voltage kV AC 6 6 Utilization category Acc. to VDE 0638 A AC-22 AC-22
Technical specications DC
Rated voltage U
Short-circuit strength kA DC 8 8 8 8 8 25 25 25 25 25 25 8 8 8 8 Utilization category Acc. to EN 60947-3 A DC-22 B DC-20B
n
Un acc. to UL V AC 700
n
In acc. to UL/CSA A
Acc. to EN 60947-3 A AC-22 B,
n
Un acc. to UL V DC
DIN EN 60947-3 (VDE 0660-107)
EC/EN 60947-3
V AC 230/400,
240/415
A 63 16 16 63 100 16/63 16/63 2 ... 100 20 100 160 160 250 400 630 1250 160 250 400 630 250 400 63 63 25 63
AC-23 B (35A)
V DC 65 (1P),
130 (2P)
DIN VDE 0638; DIN EN 60947-3 (VDE 0660-107)
EC/EN 60947-3
230/400,
240/415
AC-22 A AC-20B
48 (1P),
110 (2P)
5SG16
5SG55
IEC 60269-3;
DIN VDE 0636-3
400 400 400 500, 690, 750 400 690 690
250 250 250 500, 600, 750 250 440 440 440 440 440 1000 1000 1000 1000 1500 1500 250 250 600
5SG18 5SG1301
5SG56
5SG1701 5SG5301 5SG5701
IEC 60269-3;
DIN VDE
0636-3
5SG1302 5SG1702 5SG5302 5SG5702
IEC 60269-3;
DIN VDE
0636-3
5SF
IEC 60269-3;
DIN VDE 0635;
DIN VDE 0636-3;
CEE 16
Further technical specications
Overvoltage category IV IV III; II (DIAZED fuse
Max. power dissipation of fuse links (conductor cross-section used)
Pollution degree
W 12 25 32 45 60 90 40 90 110 130 90 110
bases made of
molded plastic for
use at 690 V AC /
600 V DC)
Further information
Catalog LV 10 See page 7/13 See page 7/12 See page 7/16 See page 7/18 See page 7/22 See page 7/22 See page 7/21 See page 7/20
1)
Extended rated voltage up to 1000 V (except LV HRC bus-mounting bases).
7/8
Siemens LV 10 · 04/2020
System overview, page 7/4
© Siemens 2020
Fuse holders and bases
|
Fuse Systems
Cylindrical fuse
holders
LV HRC fuse bases,
LV HRC bus-mounting bases
Photovoltaic cumulative
fuse bases
NEOZED bus-
mounting bases
for 5SG 60 mm
compact busbar
NEOZED SR60 bus­mounting
bases
systems
0 1 2 3 4 1 1L 2L 3L 1XL 2XL D02 D02 DII DII
00
3NW73.. 3NW72.. 3NH7...-4 5SG6208 5SG6202
IEC 60269-1, -2, -3;
NF C 60-200,
NF C 63-210, -211;
NBN C 63269-2-1;
CEI 32-4, -12; UL 4248-1
(switching without load)
IEC 60269-1, -2; EN 60269-1;
DIN VDE 0636-2, UL 4248-1 (only downstream from the
branch protection)
1)
1)
1)
1)
690
690
690
1)
690
690 400 400 500 690
IEC 60269, IEC 60269-2,
IEC 60947
IEC 60269-3,
DIN VDE 0636-3
5SG6206
5SG6207
IEC 60269-3,
DIN VDE
0636-3
DIAZED SR60
bus-mounting bases
5SF6014 5SF6015 5SF6020
IEC 60269-3,
DIN VDE
0636-3
5SF6214 5SF6215 5SF6220
IEC 60269-3,
DIN VDE
0636-3
7
(switching without load)
System overview, page 7/4
DC-20B (switching without load)
Siemens LV 10 · 04/2020
7/9
Fuse Systems
|
Fuse holders and bases
Overview of fuse holders, bases and D0 fuse switching devices
IEC / UL IEC / UL UL
© Siemens 2020
LV HRC fuse bases,
LV HRC bus-mounting bases
Fuse holders for SITOR semiconductor fuses
(cylindrical fuse design)
Basic data
Size
Variant
000/00 0 1 2 3 4 10 × 38 mm 14 × 51 mm 22 × 58 mm 22 × 127 mm
3NC10 3NC14 3NC22 3NC23
Standards
Standards
7
Approvals
Approvals
Technical specications AC
Rated voltage U
Rated insulation voltage V AC
Short-circuit strength kA AC
Rated current I
Rated impulse withstand voltage kV AC
Utilization category Acc. to VDE 0638 A
Technical specications DC
Rated voltage U
Short-circuit strength kA DC
Utilization category Acc. to
n
Un acc. to UL V AC
n
In acc. to UL/CSA A
Acc. to EN 60947-3
n
Un acc. to UL V DC
EN 60947-3
V AC
A
A
V DC
A
IEC 60269-1, -2; EN 60269-1;
DIN VDE 0636-2, UL 4248-1 (only downstream from the
branch protection)
KEMA, UL le number E171267-IZLT2 UL 4248-1; UL File number E171267;
1)
1)
1)
1)
690
690
690
690
600 600 600
50 50
160 160 250 400 630 1250 32 50 100 63
30 50 (UL),
6 6 6
AC-22B
250 440 440 440 440 440 800 1000
25 25 25 25 25 25 50
DC-20B
690
1)
UL 4248-1; CSA C22.2;
IEC 60269-2,
IEC 60947-3
u, s u, s u, s
690 690 690 690 1500 690 690
(400 V)
UL 4248-1; CSA C22.2;
IEC 60269-2,
IEC 60947-3
CSA C22.2 No. 39-M
(100 at 400 V)
40 (CSA)
AC-22B (400 V)
UL 4248-1; CSA C22.2;
IEC 60269-2,
IEC 60947-3
50
(100 at 500 V)
80
AC-20B (690 V)
IEC 60269-2,
IEC 60947-3
30 100 100 200 200 200 200 200 200
AC-20B
Further technical specications
Overvoltage category
Max. power dissipation of fuse links (conductor cross-section used)
Pollution degree
W
12 25 32 45 60 90 3 (6 mm²),
Further information
Catalog LV 10
1)
Extended rated voltage up to 1000 V (except LV HRC bus-mounting bases).
7/10
Siemens LV 10 · 04/2020
4.3 (10 mm²)
2 2 2
See page 7/22 See page 7/60
5 (10 mm²),
6.5 (25 mm²)
9.5 (35 mm²), 11 (50 mm²)
(1 50 mm²)
System overview, page 7/4
15
© Siemens 2020
Fuse holders and bases
|
Fuse Systems
Cylindrical fuse holders Photovoltaic
cylindrical fuse holders
10 × 38 mm 14 × 51 mm 10 x 38 mm 10 x 85 mm
3NW70..
3NW703.-1
IEC 60269-1, -2, -3;
NF C 60-200,
NF C 63-210, -211;
NBN C 63269-2-1;
CEI 32-4, -12; UL 4248-1 UL File number E171267
U, s U
600 700 600 600 600 600 600 600
32 50 30 32 30 30 60 100 200 400
6 6 No information as the devices are only tested
(switching without load)
3NW71.. 3NW70..-4 3NW76..-4 3NW75.3-0HG
IEC 60269,
IEC 60269-2,
IEC 60947,
UL 4248-1, -18
U (E355487)
AC-20B
IEC 60269,
IEC 60269-2,
IEC 60947,
UL 4248-1, -18
U (File number
E469670, CCC)
(variants without
signal detector)
AC-20B
Class CC
fuse holders
3NW753.-1HG
UL 4248-1;
CSA C22.2
UL 4248-1;
UL File number E171267;
CSA C22.2
(switching without load)
Class J fuse holders
3NW75.3-3HG, 3NW75.3-5HG, 3NW75.3-6HG, 3NW75.3-7HG,
3NW75.3-8HG, 3NW7431-6HG, 3NW7431-7HG, 3NW7431-8HG
UL 4248-1 Ed.1, UL 4248-8 Ed.1
UL File number E171267; CSA File number 233322;
Class number 6225-01
u, s u, s CUUS CUUS u, s
Busbar device:
and certied to UL/CSA and not to IEC
AC-20B
(switching without load)
7
CUUS
1000 1500 300
600 600 600 600 600
DC-20B
(switching without load)
II II No information as the devices are only tested
4 6 3 (6 mm²),
2 2
See page 7/24 See page 7/26 See page 7/28
System overview, page 7/4
DC-20B
(switching without load)
4.3 (10 mm²)
DC-20B
(switching without load)
and certied to UL/CSA and not to IEC
No information as the devices are only tested
and certied to UL/CSA and not to IEC
See page 7/27
Siemens LV 10 · 04/2020
7/11
Fuse Systems
|
Fuse holders and bases
© Siemens 2020

MINIZED fuse switch disconnectors

Number of poles
Size Rated current
D01 2 … 6 A 5SG7611-0KK06 5SG7631-0KK06
10 A 5SG7611-0KK10 5SG7631-0KK10
16 A 5SG7611-0KK16 5SG7651-0KK16 5SG7621-0KK16 5SG7631-0KK16 5SG7661-0KK16
1P 1P+N 2P 3P 3P+N
7
7/12
Siemens LV 10 · 04/2020
System overview, page 7/4
© Siemens 2020

MINIZED switch disconnectors

Fuse holders and bases
|
Fuse Systems
Number of poles
Size Rated current
D02 25 A 5SG7133-8BA25
35 A 5SG7133-8BA35
50 A 5SG7133-8BA50
63 A 5SG7113 5SG7153 5SG7123 5SG7133 5SG7163
1)
Versions for Austria only, with permanently tted adapter sleeves and incl. fuse link
1P 1P+N 2P 3P 3P+N
Accessories
Reducers
Use Article No.
For D01 fuse links in MINIZED D02 switch disconnectors 5SH5527
Auxiliary switches (AS)
Version Article No.
1 NO contact + 1 NC contact 5ST3010
2 NO contacts 5ST3011
2 NC contacts 5ST3012
Auxiliary switches (AS) with TEST button
Version Article No.
1 NO contact + 1 NC contact 5ST3010-2
2 NO contacts 5ST3011-2
2 NC contacts 5ST3012-2
1)
1)
1)
7
System overview, page 7/4
Siemens LV 10 · 04/2020
7/13
Fuse Systems
|
Fuse holders and bases

NEOZED bus-mounting switch disconnectors

For 8US 60 mm busbar systems
Size D02
© Siemens 2020
Mounting width
1.5 MW 1.5 MW 1.5 MW
For at copper proles
Box terminals
5 mm and 10 mm 63 A 400 V AC IEC 5SG7234-1
1)
In the case of permanent load over 35 A, we recommend the use of lateral module 5SH5526. Please observe EN 60439-1, Table 1.
2)
In the case of permanent load over 35 A, we recommend the use of lateral module 5SH5533. Please observe EN 60439-1, Table 1.
Rated current I
e
Rated voltage U
e
IEC UL 508 IEC AC IEC DC UL 508
400 V AC 110 V DC IEC 5SG7230
Standard Without LED signal detector With LED
signal detector
2)
5SG7234-2
1)
2)
Suitable accessories
7
Auxiliary switches
Lateral modules
Reducers
• For signaling the switching state for bus-mounting switch disconnectors
Contacts Mounting
width
1 CO contact 0.5 MW 5SH5525
• For greater heat dissipation for loads from 35 A
Mounting width Article No. Article No. Article No.
0.5 MW 5SH5533 5SH5526 5SH5533
Use Article No. Article No. Article No.
For NEOZED D01 fuse links in SR60 bus-mounting switch disconnectors 5SH5527 5SH5527 5SH5527
Article No. Article No. Article No.
See SITOR semiconductor fuse links (cylindrical fuse design) from page 13/1
7/14
Siemens LV 10 · 04/2020
System overview, page 7/4
© Siemens 2020
Fuse holders and bases
|
Fuse Systems
7
System overview, page 7/4
Siemens LV 10 · 04/2020
7/15
Fuse Systems
|
Fuse holders and bases

NEOZED fuse bases

Comfort bases made of molded plastic Fuse bases made of molded plastic Fuse bases made of ceramic
Without LED signal detector With LED signal detector With clamp-type terminal With saddle terminal With screw head contact
© Siemens 2020
Number of poles
Size Rated current
D01 16 A 5SG1301 5SG5301 5SG1302 5SG5302 5SG1302-1 5SG5302-1 5SG1553 5SG5553
D02 63 A 5SG1701 5SG5701 5SG1702 5SG5702 5SG1702-1 5SG5702-1 5SG1653 5SG5653 5SG1693 5SG5693
D03 100 A 5SG1812
Accessories
NEOZED screw caps
Material Version Fuse size Article No.
7
Molded plastic With inspection hole D01 5SH4116
1P 3P 1P 3P 1P 3P 1P 3P 1P 3P 1P 3P
D02 5SH4163
Ceramic Without inspection hole, sealable D01 5SH4316
NEOZED adapter sleeves
Fuse size Rated current Color Article No.
D01 2 A Pink 5SH5002
D01 fuse links in D02 base and MINIZED D02 switch disconnectors
D02 20 A Blue 5SH5020
D03 80 A Silver 5SH5080
D02 5SH4363
Without inspection hole D03 5SH4100
With inspection hole D01 5SH4317
D02 5SH4362
4 A Brown 5SH5004
6 A Green 5SH5006
10 / 13 A Red 5SH5010
2 A Pink 5SH5402
4 A Brown 5SH5404
6 A Green 5SH5406
10 / 13 A Red 5SH5410
16 A Gray 5SH5416
25 A Yellow 5SH5025
32 A Violet 5SH5032
35 / 40 A Black 5SH5035
50 A White 5SH5050
7/16
Siemens LV 10 · 04/2020
System overview, page 7/4
© Siemens 2020
Fuse holders and bases
|
Fuse Systems
NEOZED covers
Fuse size Article No.
D03 5SH5233
NEOZED adapter sleeve tters
NEOZED retaining springs
Use Article No.
For D01 fuse links in D02 screw caps, 2 … 16 A 5SH5400
7
Article No.
5SH5100
System overview, page 7/4
Siemens LV 10 · 04/2020
7/17
Fuse Systems
|
Fuse holders and bases

DIAZED fuse bases

Fuse bases made of molded plastic Fuse bases made of ceramic With box terminal With clamp-type terminal With saddle terminal
© Siemens 2020
Number of poles
Size Rated current Un AC / DC Un AC / DC Un AC / DC Un AC / DC U
DII 25 A 5SF1060 5SF5068 5SF1005
DIII 63 A 5SF1260
1)
Can also be used for 690 V AC / 600 V DC.
1P 3P 1P 1P 1P
500 / 500 V 500 / 500 V 500 / 500 V 500 / 500 V 750/ 750 V
1)
5SF5268
1)
5SF1205
1)
Accessories
7
DIAZED screw caps
Material Version Fuse size Rated voltage AC / DC Article No.
Molded plastic With inspection hole NDz 500 / 500 V 5SH1112
Ceramic Without inspection hole DII 500 / 500 V 5SH112
DIAZED screw adapters
• Also for 5SF230 up to 750 V
Fuse size Rated current Article No.
DII 2 A 5SH310
DIII 32 A 5SH327
DII 500 / 500 V 5SH1221
DIII 500 / 500 V 5SH1231
DIII 500 / 500 V 5SH113
With inspection hole, sealable
Extended version DIII 690 / 600 V 5SH1170
With ne thread DIII 750 / 750 V 5SH1161
4 A 5SH311
6 A 5SH312
10 A 5SH313
16 A 5SH314
20 A 5SH315
25 A 5SH316
35 A 5SH317
50 A 5SH318
63 A 5SH320
DII 500 / 500 V 5SH122
DIII 500 / 500 V 5SH123
7/18
Siemens LV 10 · 04/2020
System overview, page 7/4
With screw head contact
AC / DC
n
5SF4230
© Siemens 2020
Fuse holders and bases
|
Fuse Systems
DIAZED adapter sleeves for screw caps
Use Article No.
For DII fuse links in DIII base 5SH302
DIAZED adapter sleeve tters
Use Article No.
For DII / DIII screw adapters 5SH3703
DIAZED cover rings
Fuse size Material Article No.
DII Molded plastic 5SH3401
DIII Molded plastic 5SH3411
DIAZED caps
Fuse size Material Article No.
DII Molded plastic 5SH202
DIII Molded plastic 5SH222
7
System overview, page 7/4
Siemens LV 10 · 04/2020
7/19
Fuse Systems
|
Fuse holders and bases
Bus-mounting bases
For 8US busbar systems
© Siemens 2020
Compact busbar systems
NEOZED design NEOZED design DIAZED design
Number of poles
Size I
D02 63 A 1.5 MW 5SG6202 5SG6206
DII 25 A 500 / 500 V 5SF6015 5SF6020
DIII 63 A 500 / 500 V
1)
Can also be used for 690 V AC / 600 V DC.
Mounting
n
width
2 MW 5SG6208 5SG6207
Un AC / DC With touch
3P 3P 3P
protection
1)
5SF6215 5SF6220
60 mm busbar systems
Standard With touch
protection
Standard With touch
protection
7
Accessories
Covers for standard version for 60 mm busbar systems
Design Fuse size Version Mounting width (1 MW = 18 mm) Article No.
NEOZED D02 Standard 1.5 MW 5SH5241
Extra wide 2 MW 5SH5242
Double width 3 MW 5SH5243
DIAZED DII 5SH2042
DIII 5SH2242
See SITOR semiconductor fuse links (cylindrical fuse design) from page 13/1