DIMENSIONS
(Units: mm)
With removable target mask attached
171.5
165
84.2
90
70
25
φ6.2
Streamlines color adjustment
in printing, even on substrates
with uorescent whitening agents
Density
Color
Illumination
Spectrodensitometer
FD-7/FD-5
3-in-1 next-generation measurement tool
Main specifi cations
Model FD-7 FD-5
Illumination/viewing system
45°a: 0°(annular illumination)
Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for refl ectance measurements.
Spectral separation device Concave grating
Wavelength range
Spectral refl ectance: 380 to 730 nm; Spectral irradiance: 360 to 730
nm
Spectral refl ectance: 380 to 730 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Measurement area Ø3.5mm
Light source LED
Measurement range Density: 0.0D to 2.5D; Refl ectance: 0 to 150%
Short-term repeatability
Density: σ0.01D
Colorimetric: Within σΔE00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
Inter-instrument agreement
Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard
conditions)
Measurement time Approx. 1.4 s (single-point refl ectance measurement)
Displayed values
Colorimetric values, color-difference values, density values,
density-difference values, dot area ratio, dot gain, PASS/FAIL
judgment, illuminance, correlated color temperature
Colorimetric values, color-difference values, density values, densitydifference values, dot area ratio, dot gain, PASS/FAIL judgment
Measurement conditions
Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut
fi lter); User-defi ned illuminant
Illuminants A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defi ned illuminant
Observers 2° Standard Observer, 10° Standard Observer
Color spaces Lab, LCh, Hunter Lab, Yxy, XYZ and color-difference in these color spaces
Color-difference equations
Δ
Eab (CIE 1976), ΔE94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l:c)
Indexes WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index
Density ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536
Storable data Colorimetric target data: 30 data; Density target data: 30 data
Display language English, French, German, Spanish, Japanese, Chinese (Simplifi ed)
Scanning measurements
Scanning measurement of a color chart can be performed. N/A
Interface USB 2.0
Output data
Displayed values; Spectral reflectance data; Spectral irradiance
data
Displayed values
Power Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power
Dimensions (W × D × H) 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)
Weight Approx. 350g (Body only); Approx. 430g (With target mask attached)
Operating temperature/
humidity range
10 to 35°C, 30 to 85% relative humidity with no condensation
Storage temperature/humidity
range
0 to 45°C, 0 to 85% relative humidity with no condensation
1 Illumination for wavelengths under 400nm is unidirectional. 2 Available when using PC software.
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified power supply
s
voltage. Improper connection may cause a fire or electric shock.
Certificate No : LRQ 0960094/A
Registration Date : March 3, 1995
Certificate No : JQA-E-80027
Registration Date : March 12, 1997

3-in-1 lightweight, handheld spectrodensitometer that measures color, density, and illumination.
CMYKLab
Lv, Tcp (Color temperature)
An ideal instrument for the printing and digital-imaging industries.
Color
Uniquely corresponds to Measurement Condition M1 of ISO 13655
The world's first M1 type. Konica Minolta's original VFS (Virtual Fluorescence Standard) technology enables
Lab measurements corresponding to ISO 13655 Measurement Condition M1 (CIE Illuminant D50).
In addition, color measurements corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A) and
M2 (illumination with UV-cut fi lter) can also be taken.
Long-life LED
Industry's fi rst automatic wavelength compensation function
• Wavelength compensation is performed during
white calibration without requiring additional work.
• Until now, wavelength compensation could only be
carried out as one part of manufacturer servicing.
This task is now performed whenever white
calibration is done, helping to maintain the high
reliability of measurement values until the next
periodic servicing.
Scan measurements can be performed.
• Manual scan measurements can be
performed when the instrument is
connected to a PC.
• With optional software basICColor
catch all, the colorimetric values, density
values, and spectral refl ectance values
of various test charts (MediaWedge
ECI2002, IT8.7/3, etc.) can be measured
in a single operation.
Wavelength-direction shift
Spectral reflectance
Wavelength
1
lamp light
source
World's lightest
2
• The main body weighs only about 350g, and even with the
target mask attached it's only about 430g, lighter than any
previous spectrodensitometer.
• This reduces the load on the user's arm during work, improving
effi ciency when taking measurements over a long time.
2 Display-equipped spectrodensitometer.
As of November 1, 2010
Worry-free after-sales service
• Worldwide service centers provide rapid support when needed.
• A comprehensive service network is in place to ensure that your instrument is always
in top shape.
Simple operation
• Measurements of density, dot area ratio, dot
gain, color, and illumination are simple.
• Instructions in the LCD screen guide operation,
so anyone can take measurements easily.
Density
Illumination
Enables color measurements that correspond
more closely with visual evaluation.
When using conventional instruments to measure materials printed on substrates containing fl uorescent
whitening agents (FWA), large differences between the results of measurements and visual evaluation
may occur. With the new FD-7/FD-5, measurement results correspond more closely to visual evaluation
results, including the effects of any FWA in the paper.
Measurementintensitydistribution
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
Relativeintensit y(a.u.)
0.2
0
300320340360380400420440460480500
A
D50
D65
A(U vc u t )
Wavelength(nm)
120
100
80
60
40
Spectralreflectance(%)
20
0
380 430 480 530 580 630 680 730
1
Wavelength(nm)
A
D50
D65
A(UVcut )
Spectral output
Since both spectral refl ectance data (380 to 730 nm) under various light sources and spectral irradiance data
(360 to 730 nm) of environmental lighting can be measured and output to a computer, it makes the FD-7 ideal for
research and development applications.
1: Function available only on FD-7.
Illumination environment light can be measured.
• The illuminance and color temperature in a color viewing cabinet
or the actual ambient light under which printed materials will be
evaluated can be measured.
• Colorimetric values under the measured light source (which more
closely correspond to on-site visual evaluation) can be calculated.
This ensures customers receive the colors they want and
eliminates time and labor lost resolving customer complaints.
SYSTEM DIAGRAM
Spectrodensitometer
FD-7/ FD-5
Protection
Glass
FD-A04
White
Calibration Plate
FD-A06
USB Cable (
IF-A17 (Europe)
IF-A23 (worldwide except Europe)
Target Mask
FD-A01
Shape may vary by region.)
PC
(commercially available)
Ruler
FD-A02
Illuminance Adapter
FD-A03
AC Adapter
(Shape may
vary by region.)
Soft Case
FD-A05
Color Management
Software
basICColor catch all
FD-5, FD-7
Standard accessories
Standard accessories
only of FD-7
Optional
accessories
1
XY Automatic ColorMeasurement Stage
ColorScoutA3+

Color Management Software
NEW
XY Automatic Color-Measurement Stage
(Optional accessory)
bas
ICC
olor catch all
For major effi ciency increases in daily color control work.
Enables color reproduction closer to visual evaluation with simple operation.
With basICColor catch all, commonly used templates and jobs are already included, so there is no need for measurement preparations such as
setting target values, tolerances, etc.
When the software is started, just select the required measurement conditions in the Job Management screen. You can then connect
immediately to the Spectrodensitometer FD-7 or FD-5, and PDF reports can be created and output automatically.
Data is stored in ISO format (ISO 12642-2), so they can be fed back to profi le creation software. Since the FD-7 and FD-5 are the industry's fi rst
spectrodensitometers to offer M1 measurement condition, color reproduction closer to visual evaluation becomes possible.
Measure various types of standard color charts to easily check
whether proof and printed colors are within offset printing standards.
When the FD-7 is used, scan measurements (which were impossible with conventional
spectrodensitometers) can be taken, so data from multiple color patches can be obtained in one
operation.
Pass/Fail judgement results can be seen at a glance.
Stricter in-house company tolerances or standard tolerance values specifi ed by customers can
be set and the results of pass/fail judgements based on those tolerances can be easily seen.
Three-dimensional color solid display enables easy checking of color shifts.
Target colors can also be created from ICC profi les.
+
ColorScoutA3
(Optional accessory)
The ColorScoutA3+ enables accurate, high-effi ciency
measurements of color charts with the Spectrodensitometer
FD-7 and FD-5. It enables
automatic positioning and
measurement of the instrument,
providing higher repeatability
and reducing labor compared
to manual measurements.
XY automatic color-measurement stage.
Table available with either white surface or black
surface.
Using the ColorScoutA3+ with the FD-7 or FD-5 makes it easier to measure colorimetric data of color
charts under ISO 13655 Measurement Condition M1. Measurement Condition M1 colorimetric data
can be used to create color profi les that more closely match visual evaluation.
Maximum measurable chart size of 320 x 460 mm improves measurement effi ciency by allowing even
large color charts to be measured in a single procedure without the need to cut up or tile the charts.
For ISO 12647-2 printing certifi cation
checks and print process quality
management.
Enables measurement of Fogra and IDEAlliance
standards and certification checking.
In addition to CIELAB for color, evaluation results
for CMYK dot gain and mid-tone spread as
required for the above certification checking can
also be easily obtained. This can help discover
and resolve problems in the printing process at
an early stage.
Templates/targets for use with Spectrodensitometer FD-7/FD-5
For proof checking
and QA
For printing
certifi cation and QC
For CMYK printer
profi le creation
For RGB printer
profi le creation
Minimum computing requirements
OS Windows
CPU Intel
Memory 512MB
Hard disk At least 100MB of available disk space
Display Display unit capable showing at least 1024 x 768
Other DVD-ROM drive (for installation)
Compatible instruments
Various types of Ugra/Fogra MediaWedge
CMYK; Various types of IDEAlliance Digital
Control Strip 2009
Various types of FOGRA Stepwedge;
IDEAlliance P2P25X
ECI 2002 random; IT8/7-4 random; IT8/7-3
random; basICColor CMYKick-Target7
TC9.18; Various types of basICColor dropRGB
Tar get
®
XP SP3 (32-bit); Windows® Vista (32-
®
bit); Windows
®
Pentium® 4 Processor
dots/24-bit color (16 million colors)
USB 2.0 port (for instrument connection)
Microsoft Internet Explorer Ver. 7 or later (to
obtain license)
Spectrodensitometer FD-7 and FD-5
7 (32-bit)
Features
Color notations CIELAB; CIEXYZ; Density (ISO Status T, ISO Status E, ISO Status A); Dot gain
Color-difference
equations
Observer 2°; 10°
Observation
illuminants
Measurement
conditions
Basic functions Calibration; Spot measurement; Scan measurement (With FD-7 only);
Output items Sample ID; CMYK or RGB; CIEXYZ: CIELAB: Density (ISO Status T, ISO
Printing control
items
Printing
standards
Import /expor t Data fi les: ISO format (ISO 12642-2); PDF report output; Label printing
Display
languages
E
(CIE 1976); E
ab
(CIEDE2000); CMC (l:c); DIN99
A; B; C; D50; D55; D65; D75; ID50; ID65; E; F1 to F12
A (ISO 13655 Measurement Condition M0); C; D50 (ISO 13655 Measurement
Condition M1); D65; ID50; ID65; F2 ; F6; F7; F8; F9 ; F10; F11; F12; A+UV cut
(ISO 13655 Measurement Condition M2); User-defi ned illuminant
Illumination measurement (With FD-7 only); Job creation/management; Target
value setting (reference fi le, ICC profi le); Averaging of multiple measurements;
Graph display; Report output (Pass/Fail message setting)
Status E, ISO Status A); Spectral data (With FD-7 only); Dot gain
Color tolerance range control; Primary color control; Dot gain control; Mid-tone
spread control
ISO 12647; FOGRA39, FOGRA27; SWOP; GRACoL
English; German; French; Spanish; Italian; Japanese; Chinese (Simplifi ed)
(CIE 1994; graphics); E
94
(CIE 1994; textile); E00
94
Measurement of user-designed charts is also possible. The included ColorChart software makes it
easy to create a defi nition fi le for measuring the user-designed chart.
Measurement data Chart design screen
Main specifi cations XY Automatic Color-Measurement Stage ColorScoutA3 +
Measurement range
(maximum chart size)
Measuring instrument Spectrodensitometer FD-7, FD-5
Minimum chart patch size 6 x 6 mm
Maximum sample thickness 1.5 mm
Operating temperature/
humidity range
Storage temperature/
humidity range
Standard accessories Mounting bracket for FD-7, Height adjustment plate, ColorChart software, RS-232C
ColorChart minimum computing requirements
OS; CPU Windows
Hard disk; Memor y 30MB or more available disk space; 64MB or more
Display 1024 x 800 pixels or more
320 x 460 mm
10 to 35°C, relative humidity 30 to 85% with no condensation
-20 to 60°C, relative humidity 0 to 90% with no condensation
cable, USB to RS-232C serial conver ter, USB cable AC power cord, White calibration
plate for ColorScoutA3+
®
XP(32-bit), Windows®Vista(32-bit); 300MHz or faster