Siemens FD-5, FD-7 User Manual

9242-4897-10 BCJEPK 5
• Displays shown are for illustration purpose only.
• The specifi cations and drawings given here are su
bject to change without prior notice.
• KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "Giving Shape to Ideas" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC.
• The basICColor logo is a registered trademark of basICColor GmbH.
• Other company names and product names used herein are trademarks or registered trademarks of their respective companies.
©2010 KONICA MINOLTA OPTICS, INC.
DIMENSIONS
(Units: mm)
With removable target mask attached
171.5 165
84.2
90 70
25
φ6.2
Streamlines color adjustment
in printing, even on substrates
with  uorescent whitening agents
Density
Color
Illumination
Spectrodensitometer
FD-7/FD-5
3-in-1 next-generation measurement tool
Main specifi cations
Model FD-7 FD-5
Illumination/viewing system
45°a: 0°(annular illumination) Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for refl ectance measurements.
Spectral separation device Concave grating
Wavelength range
Spectral refl ectance: 380 to 730 nm; Spectral irradiance: 360 to 730 nm
Spectral refl ectance: 380 to 730 nm
Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Measurement area Ø3.5mm Light source LED Measurement range Density: 0.0D to 2.5D; Refl ectance: 0 to 150%
Short-term repeatability
Density: σ0.01D Colorimetric: Within σΔE00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
Inter-instrument agreement
Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions)
Measurement time Approx. 1.4 s (single-point refl ectance measurement)
Displayed values
Colorimetric values, color-difference values, density values, density-difference values, dot area ratio, dot gain, PASS/FAIL judgment, illuminance, correlated color temperature
Colorimetric values, color-difference values, density values, density­difference values, dot area ratio, dot gain, PASS/FAIL judgment
Measurement conditions
Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut
fi lter); User-defi ned illuminant Illuminants A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defi ned illuminant Observers 2° Standard Observer, 10° Standard Observer Color spaces Lab, LCh, Hunter Lab, Yxy, XYZ and color-difference in these color spaces Color-difference equations
Δ
Eab (CIE 1976), ΔE94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l:c) Indexes WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index Density ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536 Storable data Colorimetric target data: 30 data; Density target data: 30 data Display language English, French, German, Spanish, Japanese, Chinese (Simplifi ed) Scanning measurements

Scanning measurement of a color chart can be performed. N/A
Interface USB 2.0
Output data

Displayed values; Spectral reflectance data; Spectral irradiance data
Displayed values
Power Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power Dimensions (W × D × H) 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached) Weight Approx. 350g (Body only); Approx. 430g (With target mask attached) Operating temperature/
humidity range
10 to 35°C, 30 to 85% relative humidity with no condensation
Storage temperature/humidity range
0 to 45°C, 0 to 85% relative humidity with no condensation
1 Illumination for wavelengths under 400nm is unidirectional. 2 Available when using PC software.
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified power supply
s
Certificate No : LRQ 0960094/A
Registration Date : March 3, 1995
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
3-in-1 lightweight, handheld spectrodensitometer that measures color, density, and illumination.
CMYKLab
Lv, Tcp (Color temperature)
An ideal instrument for the printing and digital-imaging industries.
Color
Uniquely corresponds to Measurement Condition M1 of ISO 13655
The world's first M1 type. Konica Minolta's original VFS (Virtual Fluorescence Standard) technology enables Lab measurements corresponding to ISO 13655 Measurement Condition M1 (CIE Illuminant D50). In addition, color measurements corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A) and M2 (illumination with UV-cut fi lter) can also be taken.
Long-life LED
Industry's fi rst automatic wavelength compensation function
• Wavelength compensation is performed during white calibration without requiring additional work.
• Until now, wavelength compensation could only be carried out as one part of manufacturer servicing. This task is now performed whenever white calibration is done, helping to maintain the high reliability of measurement values until the next periodic servicing.
Scan measurements can be performed.
• Manual scan measurements can be performed when the instrument is connected to a PC.
• With optional software basICColor catch all, the colorimetric values, density values, and spectral refl ectance values of various test charts (MediaWedge ECI2002, IT8.7/3, etc.) can be measured in a single operation.
Wavelength-direction shift
Spectral reflectance
Wavelength
1
lamp light
source
World's lightest
2
• The main body weighs only about 350g, and even with the target mask attached it's only about 430g, lighter than any previous spectrodensitometer.
• This reduces the load on the user's arm during work, improving effi ciency when taking measurements over a long time.
2 Display-equipped spectrodensitometer.
As of November 1, 2010
Worry-free after-sales service
• Worldwide service centers provide rapid support when needed.
• A comprehensive service network is in place to ensure that your instrument is always in top shape.
Simple operation
• Measurements of density, dot area ratio, dot gain, color, and illumination are simple.
• Instructions in the LCD screen guide operation, so anyone can take measurements easily.
Density
Illumination
Enables color measurements that correspond more closely with visual evaluation.
When using conventional instruments to measure materials printed on substrates containing fl uorescent whitening agents (FWA), large differences between the results of measurements and visual evaluation may occur. With the new FD-7/FD-5, measurement results correspond more closely to visual evaluation results, including the effects of any FWA in the paper.
Measurementintensitydistribution
2
1.8
1.6
1.4
1.2 1
0.8
0.6
0.4
Relativeintensit y(a.u.)
0.2 0
300320340360380400420440460480500
A D50 D65 A(U vc u t )
Wavelength(nm)
120
100
80
60
40
Spectralreflectance(%)
20
0
380 430 480 530 580 630 680 730
1
Wavelength(nm)
A D50 D65 A(UVcut )
Spectral output
Since both spectral refl ectance data (380 to 730 nm) under various light sources and spectral irradiance data (360 to 730 nm) of environmental lighting can be measured and output to a computer, it makes the FD-7 ideal for research and development applications.
1: Function available only on FD-7.
Illumination environment light can be measured.
• The illuminance and color temperature in a color viewing cabinet or the actual ambient light under which printed materials will be evaluated can be measured.
• Colorimetric values under the measured light source (which more closely correspond to on-site visual evaluation) can be calculated. This ensures customers receive the colors they want and eliminates time and labor lost resolving customer complaints.
SYSTEM DIAGRAM
Spectrodensitometer
FD-7/ FD-5
Protection Glass
FD-A04
White
Calibration Plate
FD-A06
USB Cable (
IF-A17 (Europe) IF-A23 (worldwide except Europe)
Target Mask
FD-A01
Shape may vary by region.)
PC
(commercially available)
Ruler
FD-A02
Illuminance Adapter
FD-A03
AC Adapter
(Shape may vary by region.)
Soft Case
FD-A05
Color Management Software basICColor catch all
FD-5, FD-7 Standard accessories
Standard accessories only of FD-7
Optional accessories
1
XY Automatic Color­Measurement Stage
ColorScoutA3+
Loading...
+ 1 hidden pages