Description of the device

Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
Document order number: C79000-G8976-C283
Ⓟ
01/2018 Subject to change
Copyright © Siemens AG 2018.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
indicates that death or severe personal injury will result if proper precautions are not taken.
indicates that death or severe personal injury may result if proper precautions are not taken.
indicates that minor personal injury can result if proper precautions are not taken.
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
3
What the consignment contains
The following components are supplied with the CP 5711:
● CP 5711 communications processor
● USB cable
● 2-pin, plug-in terminal strip for external 24 V power supply
Please check that the consignment you have received is complete. If it is not complete,
please contact your supplier or your local Siemens office.
Validity of this documentation
These operating instructions are valid for the following product:
● CP 5711
Article number: 6GK1 571-1AA00
Content of this documentation
These operating instructions contain information about the installation and configuration of
the CP 5711 communications processor.
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support pages
under the following entry ID:
34803449 (https://support.industry.siemens.com/cs/ww/en/view/34803449
)
The documents listed below contain more detailed information on commissioning and using
the communications processor. You will find this documentation on the Product Support
pages on the Internet under the following entry link:
Support (https://support.industry.siemens.com/cs/ww/en/ps
)

Preface
CP 5711
4 Operating Instructions, 02/2018, C79000-G8976-C283-05
Enter the entry ID shown below of the relevant manual as the search item.
●
Configuration manual Commissioning PC Stations
This provides you with detailed information on commissioning and configuring SIMATIC
NET PC communications modules.
Entry ID:
109488960 (https://support.industry.siemens.com/cs/ww/en/view/109488960
)
●
System manual SIMATIC NET Industrial Communication with PG/PC
Entry ID:
77376110 (https://support.industry.siemens.com/cs/ww/en/view/77376110
)
–
Entry ID:
77378184 (https://support.industry.siemens.com/cs/ww/en/view/77378184
)
The system manuals introduce the topic of industrial communication and explain the
communications protocols used. There is also a description of the OPC interface as
user programming interface.
●
Installation manual "SIMATIC NET PC Software"
This document contains detailed information on installing the "SIMATIC NET
PC Software".
Entry ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602
)
●
System manual PROFIBUS Network Manual
In this document you will find detailed information about setting up a PROFIBUS network.
Entry ID:
35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591
)
SIMATIC NET documentation
You will find the entire SIMATIC NET documentation on the pages of Product Support:
15247 (https://support.industry.siemens.com/cs/ww/en/ps/15247
)
Go to the required product group and make the following settings:
→ Entry list → Entry type "Manuals / Operating Instructions"
The following and possibly other names not identified by the registered trademark sign ® are
registered trademarks of Siemens AG:
SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614,
CP 5622

Preface
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
5
In addition to the product documentation, the comprehensive online information platform of
Siemens Industry Online Support at the following Internet address:
(
http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=
en)
Apart from news, there you will also find:
● Project information: Manuals, FAQs, downloads, application examples etc.
● Contacts, Technical Forum
● The option submitting a support query:
(
https://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid
=38718979&caller=view)
● Our service offer:
Right across our products and systems, we provide numerous services that support you
in every phase of the life of your machine or system - from planning and implementation
to commissioning, through to maintenance and modernization.
You will find contact data on the Internet at the following address:
(http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en
)
SITRAIN - Training for Industry
The training offer includes more than 300 courses on basic topics, extended knowledge and
special knowledge as well as advanced training for individual sectors - available at more
than 130 locations. Courses can also be organized individually and held locally at your
location.
You will find detailed information on the training curriculum and how to contact our customer
consultants at the following Internet address:
(www.siemens.com/sitrain
)
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary on the Internet at the following address:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045
)

Preface
CP 5711
6 Operating Instructions, 02/2018, C79000-G8976-C283-05

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
7
Preface ................................................................................................................................................... 3
1 Description of the device ......................................................................................................................... 9
1.1 Product characteristics.............................................................................................................. 9
1.2 PROFIBUS interface ............................................................................................................... 11
1.3 Meaning of the LED display .................................................................................................... 12
2 Software installation .............................................................................................................................. 13
2.1 Installing the "SIMATIC NET PC Software" ............................................................................ 13
2.2 Uninstalling the "SIMATIC NET PC Software"........................................................................ 14
3 Hardware installation ............................................................................................................................. 15
3.1 Connecting to the PG/PC ....................................................................................................... 15
3.2 Hardware compatibility............................................................................................................ 18
3.3 External power supply............................................................................................................. 19
3.4 Installing on a DIN rail ............................................................................................................. 21
4 Configuration ........................................................................................................................................ 23
5 Technical specifications ........................................................................................................................ 25
A Approvals .............................................................................................................................................. 27
B Dimension drawing ............................................................................................................................... 31

Table of contents
CP 5711
8 Operating Instructions, 02/2018, C79000-G8976-C283-05

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
9
Product characteristics
Properties
The CP 5711 is a communications processor for connecting PCs (personal computers) or
PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are
as follows:
● Transmission speeds up to 12 Mbps.
● Floating RS-485 connector.
● Linking of up to 32 devices (PC, PG, SIMATIC S7 or ET 200) to form a network segment.
– By linking several segments with repeaters, up to 64 nodes can be connected.
● The additional interface signals for a direct link to a PLC (Programmable Logic Controller)
are supported up to 187.5 Kbps.
● Connection to PGs and PCs with a USB Interface:
– At the CP end: Type B with locking mechanism
– At the PG/PC end: Type A
– Plug and play
● With an additional DIN rail holder, the CP is suitable for mounting on a 35 mm DIN rail.

Description of the device
1.1 Product characteristics
CP 5711
10 Operating Instructions, 02/2018, C79000-G8976-C283-05
The following figure shows the CP 5711 communications processor mounted on a 35 mm
DIN rail:
USB interface type B with USB cable
PROFIBUS interface with D-sub male connector
Terminals for external 24 V power supply
Ground connection (cannot be seen in the figure)

Description of the device
1.2 PROFIBUS interface
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
11
PROFIBUS interface
PROFIBUS network
The physical link between the PROFIBUS interface and the PROFIBUS network is via a
floating RS-485 interface that is part of the module. Depending on the network configuration,
data rates of 9.6 Kbps up to a maximum of 12 Mbps are possible in the PROFIBUS network.
Note
You will find information about the structure of a PROFIBUS network in the system manual
"PROFIBUS Network Manual". The document is part of the Manual Collection. You will also
find this on the Produc
t Support pages under the following entry ID:
https://support.industry.siemens.com/cs/ww/en/view/35222591)
The D-sub female connector has the following pin assignment:
Socket pin 1 is not connected.
2 NC (M24) Socket pin 2 is not connected. With other MPI/DP components,
the return line of the floating 24 V power supply may be via this
Signal line B of the PROFIBUS connector.
4 RTSAS RTSAS, input signal for direct MPI link. The control signal is "1"
active when the automation system connected over a special
Input
5 M5EXT M5EXT return line (GND) of the 5 V power supply and refer-
ence potential for the signals RTSAS and RTS of the
PROFIBUS interface.
Output
6 P5EXT P5EXT power supply (+5 V) for the 5 V power supply.
(only for bus termination)
Output
7 NC (P24V) Socket pin 7 is not connected. With other MPI/DP components,
the P24V supply of the floating 24 V power supply may be via
Signal line A of the PROFIBUS connector.

Description of the device
1.3 Meaning of the LED display
CP 5711
12 Operating Instructions, 02/2018, C79000-G8976-C283-05
9 RTS RTS output signal of the CP module. The control signal is "1"
active when the device (PG or PC) is sending.
Output
Shield The shield is connected to components of the connector hous-
ing.
Meaning of the LED display
LED display
The meaning of the LED display is as follows:
The CP is connected to an active USB connector
There is no connection to an active USB connector
PWR EXT (green) On There is an additional power source connected to the CP via the exter-
Off There is no external power supply connected to the CP. Power is sup-
plied only via the active USB interface.
IDENT (green) Flashes regularly Identification of the CP 5711 to distinguish it from other CPs in the
same PG/PC
Using a relevant diagnostics function in the "Communications Settings"
configuration tool or the "Station Configuration Editor", you can activate
these LEDs for test purposes.
A node was detected on PROFIBUS
Exception status; unexpected runtime error
Red flashes cyclically
(3 times fast, then
Bus disruption. You will find the possible causes in the message box
that appears on the screen
Off No node was detected on PROFIBUS
The CP is actively involved in data traffic

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
13
Installing the "SIMATIC NET PC Software"
"SIMATIC NET PC Software"
The "SIMATIC NET PC software" is one of several software packages with which you can
operate the communications processor in your PG/PC.
To configure the communications processor, you require additional configuration software.
You will find information on the configuration software in the section "Configuration
(Page 23)".
The plug and play function is activated in the BIOS of your PG/PC.
Prior to hardware installation
Install the software as described in the installation manual "SIMATIC NET PC Software".
You will find this installation manual on the Product Support pages under the following entry
ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602
)
You should also note the current information on the "SIMATIC NET PC software" on the
Product Support pages:
Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm
)
After the hardware installation
After installing the communications processor, your PG/PC automatically searches for a
suitable driver.
1. Follow the instructions of the Hardware Wizard of Windows.
2. Do not activate the search for drivers on the Internet.

Software installation
2.2 Uninstalling the "SIMATIC NET PC Software"
CP 5711
14 Operating Instructions, 02/2018, C79000-G8976-C283-05
Uninstalling the "SIMATIC NET PC Software"
Condition
The "SIMATIC NET PC Software" is installed on the PG/PC.
Note
The recommended procedure removes the entire "SIMATIC NET PC Software" on the
PG/PC, not only the driver for the communications processor.
Uninstall the entire software package as described and recommended in the installation
manual "SIMATIC NET PC Software".
You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the
Product Support pages under the following entry ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602
)

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
15
Connecting to the PG/PC
Safety notices
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
To comply with EC Directive 94/9 (ATEX95), this enclosure must meet the requirements of
at least IP54 in compliance with EN 60529.
If the cable or conduit entry point exceeds 70 °C or the branching point of conductors
exceeds 80 °C, special precautions must be taken. If the device is operated at an ambient
temperature of 0 °C - 60 °C, make sure that you use cables with a permitted ambient
temperature of at least 80 °C.
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
Do not use any parts that show evidence of damage.
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR
COMBUSTIBLE ATMOSPHERE IS PRESENT.

Hardware installation
3.1 Connecting to the PG/PC
CP 5711
16 Operating Instructions, 02/2018, C79000-G8976-C283-05
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2 OR ZONE 2.
DO NOT OPEN WHEN ENERGIZED.
Notes on parallel operation with other USB devices
Note
The use of other USB devices (for example a WebCam, bulk memory) on the PG/PC can
impair the performance of the communicat
Note
Removing and inserting USB devices can cause functional disruptions on the USB interface.
In extreme cases, communication via the communications processor may even be aborted
making it necessary to restart the application.
Note
• First install the software
First install the software before you connect the communications processor to the PG/PC,
see the section Software installation (Page 13).
• Activated plug and play function
The plug and play function must be activated in the BIOS of your PG/PC.

Hardware installation
3.1 Connecting to the PG/PC
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
17
Permitted number of communications processors in the PG/PC
The driver software supports a maximum of 1 CP 5711 per PG/PC.
Before you connect the communications processor to your PG/PC, note the following
information:
To connect the communications processor, use only the supplied USB cable or another USB
cable suitable for industrial use.
To achieve the guaranteed configuration limits with all protocols and at all bus transmission
speeds, you should use at least a USB 2.0 high-speed connector.
You should preferably use the USB connectors located at the back of the housing of your
PG/PC. The front USB connectors usually have a lower signal quality.
We recommend that you do not use any additional USB hubs.
Delete existing configurations before you disconnect the communications processor from
your PG/PC.
You must also log off the communications processor reliably before you disconnect the
communications processor from the PG/PC. Click the "Safely Remove Hardware" icon in the
taskbar notification area.

Hardware installation
3.2 Hardware compatibility
CP 5711
18 Operating Instructions, 02/2018, C79000-G8976-C283-05
Hardware compatibility
Compatibility with other communications processors
The CP 5711 can replace a CP 5512.
Please note: The CP 5711 is a USB module. A CP 5512, on th
e other hand, is connected
via a CardBus interface. This means that you can only replace a CP 5512 with a CP 5711
if there is a USB connector available on the PG/PC.
• If the CP 5512 has been removed from the PG/PC, no configuration changes need to be
ou can adopt the configuration of the CP 5512. To do this, you simply need to reload the
When loading the CP 5512 configuration, the CP 5512 has priority
over a CP 5711. As long as a CP 5512 is connected, its configuration cannot be adopted
by a CP 5711. You should therefore remove the CP 5512 from your PC/PG.
Procedure for replacement
To replace a configured, connected CP 5512 with a CP 5711, follow the steps below:
1. Delete the configured CP 5512 from the "Station Configuration Editor".
2. Remove the CP 5512 hardware from the PG/PC.
3. Restart your PG/PC.
Note
Note that you need to have installed at least SIMATIC NET PC Software Edition 2008
including SP1 to be able to operate the CP5711.
4. Connect the CP 5711 to the PG/PC.
The plug and play function of Windows automatically searches for a driver.
5. Follow the instructions of the Hardware Wizard of Windows.
Do not activate the search for drivers on the Internet.
6. Download the CP 5512 configuration.

Hardware installation
3.3 External power supply
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
19
External power supply
Safety notices
Safety extra-low voltage - SELV
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1
may be connected to the power supply terminals. The power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code
(r) (ANSI / NFPA 70).
Devices operated with a redundant power supply
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
Note
Overvoltage protection
If the communications processor is supplied over long 24 V power supply lines or networks,
measures are necessary to prevent coupling of strong ele
ctromagnetic pulses on the supply
lines. Such coupling can result, for example, due to lightning or switching of large inductive
loads.
One of the tests used to attest the immunity of the communications processor to
electromagnetic interference is the "sur
ge immunity test" according to EN 61000-4-5. This
test requires overvoltage protection for the power supply line. A suitable device is, for
example, the Dehn Blitzductor BVT
AD 24V type no. 918 402 or a comparable protective
NE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D-92306 Neumarkt,
Conditions for the external power supply
The CP 5711 can also be operated with an external power supply with 24 VDC. You require
this external power in the following situations:
● The CP 5711 is operated on an external hub without its own power supply.
● The USB interface on the PC is a low-power interface that supplies only 100 mA.
● The end termination must be activated on the PROFIBUS connector if the CP 5711 is
located at the end of the cable. If you want this termination to be active even when no
USB cable is connected, an external power supply is necessary.

Hardware installation
3.3 External power supply
CP 5711
20 Operating Instructions, 02/2018, C79000-G8976-C283-05
Requirements of the external power supply
Use an external power supply with the following characteristics:
● Rate voltage 24 VDC
● Permitted range 22.8 to 25.2 VDC
● Current consumption max. 300 mA
● Safety extra low voltage (SELV) to EN 60950
Disconnection from the external power supply
First disconnect the USB connection
Keep to the order below if you disconnect the communications processor from the external
power supply. Otherwise, you may encounter uncontrolled interruptions in communication.
Follow the steps below to disconnect the communications processor from the external power
supply:
1. First, shut down any communication via the CP 5711.
2. Disconnect the USB connection from the device to the PC.
3. Disconnect the external power supply from the device.

Hardware installation
3.4 Installing on a DIN rail
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
21
Installing on a DIN rail
Condition
To mount the communications processor on a 35 mm DIN rail, you require an additional DIN
rail holder. You can obtain this holder under the article number 6GK1 571-1AA00-0AH0.
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
To comply with EC Directive 94/9 (ATEX95), this enclosure must meet the requirements of
at least IP54 in compliance with EN 60529.
Lower DIN rail holder with spring catch

Hardware installation
3.4 Installing on a DIN rail
CP 5711
22 Operating Instructions, 02/2018, C79000-G8976-C283-05
1. Push the DIN rail holder into the profile on the rear of the CP.
2. Place the upper DIN rail holder on the upper edge of the DIN rail so that the PROFIBUS
connector points down.
3. Pull down the DIN rail slide and hold it in position.
4. Press the lower DIN rail holder against the lower edge of the DIN rail.
5. Release the DIN rail slider.
The catch in the lower DIN rail holder locks onto the DIN rail.
Removing the communications processor from the DIN rail
To release the locking mechanism in the lower DIN rail holder, pull the DIN rail holder down.
If necessary use a screwdriver or pliers.

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
23
To be able to configure the communications processor, the following engineering or
configuration tools are available:
● STEP 7 V5.5
● STEP 7 Professional (TIA Portal)
● Communication Settings (COML S7)
The steps involved are described in the "Commissioning PC Stations" manual or in the
relevant online helps.
Compatibility during configuration
If there is not yet a CP 5711 in the hardware catalog of your STEP 7 version, you can select
a CP 5512 for configuration. The CP 5711 is compatible with the configuration of the
CP 5512.

Configuration
CP 5711
24 Operating Instructions, 02/2018, C79000-G8976-C283-05

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
25
Technical specifications of the CP 5711
Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps,
93.75 kbps, 187.5 kbps, 500 kbps,
1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps
Design 9-pin D-sub female connector with screw
locking mechanism
RS-485 (ungrounded within the SELV lim-
Properties Grounded cable shield
Floating interface signals
CP end
PG/PC end
Minimum requirement
USB socket type B with locking mechanism
USB socket type A
V 2.0
Electrical specifications of the USB connection
Properties Safety extra low voltage (SELV) to EN
60950
Direct supply via USB if provided by the
PG/PC; external power supply possible
Electrical specifications when using an external power supply
Properties Safety extra low voltage (SELV) to EN
Current consumption Maximum 300 mA

Technical specifications
CP 5711
26 Operating Instructions, 02/2018, C79000-G8976-C283-05
Technical specifications of the CP 5711
Permitted ambient conditions
Operating conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
95%, 16 h at 30°C no condensation
Storage and transportation conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
Rapid temperature change when
damp
+25...+55°C at 97% no condensation
Rapid temperature change
Vibration, operating
(EN 60068-2-6)
Frequency 10 ... 58 Hz
Frequency 58 ... 500 Hz
0.075 mm amplitude
10 m/s
2
Acceleration
Shock, operating
(EN 60068-2-27)
Half sine
Time
Design, dimensions and weight
Dimensions (W x H x D) in mm
Electromagnetic compatibility
Emission
• to EN 55022
• to FCC
Class B
Class A
Immunity On signal cables
• Surge to EN 610004-5
• Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
• Contact discharge to IEC 61000-
4-2
to radiated radio frequencies
• to EN 61000-4-3
10 V/m at 80 MHz ... 2 GHz
10 V/m, 80% amplitude modulation at
• to EN 61000-4-6
10 kHz ... 80 MHz

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
27
Note
The specified approvals apply only
when the corresponding mark is printed on the
communications processor.
Electromagnetic compatibility - EMC directive
The communications processor meets the requirements of the EC Directive:2004/108/EEC
(EMC directive).
The communications processor is designed for use in the following areas:
Residential areas, business and commercial opera-
tions, and small businesses
EN 61000-6-3 EN 61000-6-1
ATEX and FM approval (hazardous location)
The communications processor has the following approvals relating to hazardous areas:
● KEMA 07 ATEX 0145
EN 60079-15
EN 60079-0
Ex II 3 G Ex nA IIC T4 Gc
● FM 3611 Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T* and
Non Incendive / Class I / Zone 2 / Group IIC / T*
(T.. / T* = For detailed information on the temperature class, refer to the type plate.)

Approvals
CP 5711
28 Operating Instructions, 02/2018, C79000-G8976-C283-05
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
EC declaration of conformity
You will find the EC declaration of conformity for this communications processor on the
Product Support pages under the following entry ID:
58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997
)
The communications processor meets the requirements of the Australian AS/NZS 3548
standard according to EN 61000-6-3.
cULus Approval for Information Technology Equipment
cULus Listed I. T. E.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● CSA C22.2 No. 60950-1-03
Report no. E115352

Approvals
CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
29
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)

Approvals
CP 5711
30 Operating Instructions, 02/2018, C79000-G8976-C283-05

CP 5711
Operating Instructions, 02/2018, C79000-G8976-C283-05
31
CP 5711 front view and view from above
All dimensions in millimeters

Dimension drawing
CP 5711
32 Operating Instructions, 02/2018, C79000-G8976-C283-05
Front view and side view of the DIN rail holder
All dimensions in millimeters.