Siemens CP 5613 A3, CP 5614 A3 Operating Instructions Manual

Page 1
CP 5613 A3 / CP 5614 A3
_
_________________
_
_
_________________
_
_
__________________
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
SIMATIC NET
PG/PC - PROFIBUS CP 5613 A3 / CP 5614 A3
Operating Instructions
10/2012
C79000-G8976-C277-01
Preface
Description of the device
1
Software installation
2
Hardware installation
3
Configuration
4
Technical specifications
5
Approvals
A
Page 2
Legal information
Legal information Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY
Order number: C79000-G8976-C277 Ⓟ 06/2012 Technical data subject to change
Copyright © Siemens AG 2012. All rights reserved
Page 3
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
3
Preface
What the consignment contains
The following components are supplied with the CP 5613 A3 / CP 5614 A3:
● Communications processor CP 5613 A3 or communications processor CP 5614 A3
● SIMATIC NET DVD including
– SIMATIC NET PC software
– Manual Collection
● Certificate of license
Please check that the consignment you have received is complete. If it is not complete, please contact your supplier or your local Siemens office.
Validity of this documentation
These operating instructions are valid for the following products:
● CP 5613 A3 order number: 6GK1 561-3AA02
● CP 5614 A3 order number: 6GK1 561-4AA02
Content of this documentation
These operating instructions contain information about the installation and configuration of the 5613 A3 and CP 5614 A3 communications processors.
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support pages under the following entry ID: 58826514 (http://support.automation.siemens.
com/WW/view/en/58826514)
Further documentation
The documents listed below contain more detailed information on commissioning and using the communications processor. You will find this documentation on the Product Support pages on the Internet under the following entry link:
Support (http://support.automation.siemens.com/WW/view/en
)
Enter the entry ID shown below of the relevant manual as the search item.
Page 4
Preface
CP 5613 A3 / CP 5614 A3
4 Operating Instructions, 10/2012, C79000-G8976-C277-01
● Configuration manual Commissioning PC Stations
This provides you with detailed information on commissioning and configuring SIMATIC NET PROFIBUS communications modules.
Entry ID: 13542666 (http://support.automation.siemens.
com/WW/view/en/13542666)
● System manual SIMATIC NET Industrial Communication with PG/PC
– Volume 1– Basics
Entry ID: 42783968 (http://support.automation.siemens.
com/WW/view/en/42783968)
– Volume 2– Interfaces
Entry ID: 42783660 (http://support.automation.siemens.
com/WW/view/en/42783660)
The system manuals introduce the topic of industrial communication and explain the communications protocols used. There is also a description of the OPC interface as user programming interface.
● Installation manual SIMATIC NET PC Software
This document contains detailed information on installing the SIMATIC NET
PC software.
Entry ID: 42784913 (http://support.automation.siemens.
com/WW/view/en/42784913)
● System manual PROFIBUS Network Manual
In this document you will find detailed information about setting up a PROFIBUS network.
Entry ID: 35222591 (http://support.automation.siemens.
com/WW/view/en/35222591)
SIMATIC NET documentation
You will find the entire SIMATIC NET documentation on the pages of Product Support:
10805878 (http://support.automation.siemens.
com/WW/view/en/10805878)
Go to the required product group and make the following settings:
→ Entry list → Entry type "Manuals / Operating Instructions"
Online support
In addition to our product documentation, the comprehensive online information platform supports you in all aspects of our Service & Support at any time and from any location in the world. You will find this on the Internet at the following address:
(http://support.automation.siemens.
com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=
en)
Page 5
Preface
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
5
Here, you will find the following information:
● Support news, newsletter
● Product information, Product Support, Applications & Tools
● Technical Forum
● Access to other features of our Service & Support offer:
– Technical Consulting
– Engineering Support
– Field Service
Phone: +49 (0)911 895 7444
– Spare parts and repairs
Phone: +49 (0)911 895 7448
– Optimization and modernization
– Technical Support
Expert advice on technical questions with a wide range of demand-optimized services for all our products and systems.
Phone: +49 (0)911 895 7222
(https://support.automation.siemens.
com/WW/llisapi.dll?func=cslib.csinfo&lang=en&ob
jid=38718979&caller=view)
You will find contact data on the Internet at the following address: (http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en
)
SITRAIN - Siemens training for automation and industrial solutions
With over 300 different courses, SITRAIN covers the entire Siemens product and system spectrum in the field of automation and drive technology. Advanced training tailored to your needs is also available. In addition to our classic range of courses, we also offer a combination of various training media and sequences. You can, for example, use self-study programs on CD-ROM or on the Internet as preparation or to consolidate training.
You will find detailed information on our training curriculum and how to contact our customer consultants at the following Internet address:
(www.siemens.com/sitrain
)
Page 6
Preface
CP 5613 A3 / CP 5614 A3
6 Operating Instructions, 10/2012, C79000-G8976-C277-01
Page 7
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
7
Table of contents
Preface ...................................................................................................................................................... 3
1
Description of the device ........................................................................................................................... 9
1.1
Properties of the CP 5613 A3 ........................................................................................................9
1.2
Properties of the CP 5614 A3 ......................................................................................................10
1.3
PROFIBUS interface....................................................................................................................11
1.4
Meaning of the LED display.........................................................................................................13
2
Software installation................................................................................................................................. 15
2.1
Installing the SIMATIC NET PC software ....................................................................................15
2.2
Uninstalling the SIMATIC NET PC software................................................................................15
3
Hardware installation ............................................................................................................................... 17
3.1
Safety notices...............................................................................................................................17
3.2
Installing hardware.......................................................................................................................18
3.3
Hardware compatibility.................................................................................................................19
4
Configuration ........................................................................................................................................... 21
5
Technical specifications........................................................................................................................... 23
A
Approvals................................................................................................................................................. 25
Index........................................................................................................................................................ 27
Page 8
Table of contents
CP 5613 A3 / CP 5614 A3
8 Operating Instructions, 10/2012, C79000-G8976-C277-01
Page 9
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
9
Description of the device
1
1.1 Properties of the CP 5613 A3
Properties
The CP 5613 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows:
● Transmission speeds up to 12 Mbps.
● Floating RS-485 connector.
● Linking of up to 32 devices (PC, PG, SIMATIC S7 or ET 200) to form a network segment.
– By linking several segments with repeaters, up to 124 nodes can be connected.
● The additional interface signals for a direct link to a PLC (Programmable Logic Controller) are supported up to 187.5 Kbps.
● Installation in PGs and PCs with a PCI slot. The following is supported:
– PCI, 33 MHz / 66 MHz, 32 bits / 64 bits
– Plug and play
● Optimized for fast DP master operation (DP Base) with up to 124 DP slaves with full data consistency.
● Relief of the PC/PG with event mechanisms.
– Automatic detection of data changes.
● Fast logic support regardless of the user program.
– Automatic linking of input and output data can be set by the user program.
● Measurement of own operating temperature with temperature sensor.
● Display of the total operating hours with operating hours counter.
Page 10
Description of the device
1.2 Properties of the CP 5614 A3
CP 5613 A3 / CP 5614 A3
10 Operating Instructions, 10/2012, C79000-G8976-C277-01
Appearance
The following graphic shows the CP 5613 A3 communications processor:
&3
$
3%
1 LEDs 2 PROFIBUS interface PB1 (master or slave)
1.2 Properties of the CP 5614 A3
Properties
The CP 5614 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. In addition to the properties of the CP 5613 A3, the CP 5614 A3 also has the following features:
● Additional PROFIBUS connection as DP slave to a second DP network.
● DP master and DP slave can be operated at the same time.
● Program-controlled data transfer between master and slave module for setting up hierarchical PROFIBUS networks.
Page 11
Description of the device
1.3 PROFIBUS interface
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
11
Appearance
The following graphic shows the CP 5614 A3 communications processor:
&3
$
3%
3%
1 LEDs 2 PROFIBUS interface PB1 (master only) 3 PROFIBUS interface PB2 (slave only)
1.3 PROFIBUS interface
Note Connector with 180° cable outlet
Use the bus connector with a 180° cable outlet if you want to use the lower PROFIBUS connector (PB2, slave only) or both PROFIBUS connectors at the same time. You can obtain these connectors, for example, under the following order numbers:
6GK1 500-0FC10
6GK1 500-0EA02
Page 12
Description of the device
1.3 PROFIBUS interface
CP 5613 A3 / CP 5614 A3
12 Operating Instructions, 10/2012, C79000-G8976-C277-01
PROFIBUS network
The physical link between the PROFIBUS interface and the PROFIBUS network is via a floating RS-485 interface that is part of the module. Depending on the network configuration, data rates of 9.6 Kbps up to a maximum of 12 Mbps are possible in the PROFIBUS network.
Note
You will find information about the structure of a PROFIBUS network in the system manual "PROFIBUS Network Manual". The document is part of the Manual Collection. You will also find this on the Product Support pages under the following entry ID:
35222591 (http://support.automation.siemens.
com/WW/view/en/35222591)
PIN assignment
The D-sub female connector has the following pin assignment:
5
4
3
2
1
9
8
7
6
PIN Short name Meaning Input/output 1 NC Socket pin 1 is not connected. ­2 NC (M24) Socket pin 2 is not connected. With other MPI/DP components,
the return line of the floating 24 V power supply may be via this pin.
-
3 LTG_B Signal line B of the PROFIBUS connector. Input/output 4 RTSAS RTSAS, input signal for direct MPI link. The control signal is "1"
active when the automation system connected over a special MPI cable is sending.
Input
5 M5EXT M5EXT return line (GND) of the 5 V power supply. The current
load of an external consumer connected between P5EXT and M5EXT must not exceed a maximum of 90 mA.
Output
6 P5EXT P5EXT supply (+5 V) of the 5 V power supply. The current load
of an external consumer connected between P5EXT and M5EXT must not exceed a maximum of 90 mA (short-circuit proof).
Output
7 NC (P24V) Socket pin 7 is not connected. With other MPI/DP components,
the P24V supply of the floating 24 V power supply may be via this pin.
-
8 LTG_A Signal line A of the PROFIBUS connector. Input/output 9 RTS RTS output signal of the CP module. The control signal is "1"
active when the device (PG or PC) is sending.
Output
Shield The shield is connected to components of the connector
housing.
Page 13
Description of the device
1.4 Meaning of the LED display
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
13
1.4 Meaning of the LED display
LED display
The meaning of the LED display is as follows:
Green and yellow LED Meaning Green on: Shows the token rotation, in other words, normal operation. Green off: Incorrect bus parameters, defective bus or CP not in
operation.
Green flashes at one second intervals:
Bad database.
Green flashes fast, yellow is off: Module not started; normal status following reset. Green and yellow flashing
alternately:
When using more than one module in a PG/PC: Identification of the module by a diagnostics tool.
Green and yellow flashing synchronized:
Exception status; error in firmware.
One of the two LEDs is on, the second flashes quickly:
Error initializing the module.
Yellow on: Shows polling by the higher-level DP master. Applies only to
DP slave operation
with the CP 5614 A3
Yellow off: DP slave connector is not addressed.
Page 14
Description of the device
1.4 Meaning of the LED display
CP 5613 A3 / CP 5614 A3
14 Operating Instructions, 10/2012, C79000-G8976-C277-01
Page 15
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
15
Software installation
2
2.1 Installing the SIMATIC NET PC software
SIMATIC NET PC software
To operate the CP in your PG/PC, you require the SIMATIC NET PC software.
To configure the CP, you require additional configuration software. You will find information on the configuration software in the section Configuration (Page 21).
Condition
The plug and play function is activated in the BIOS of your computer.
Prior to hardware installation
Install the software as described in the installation manual "SIMATIC NET, PC Software". You will find this installation manual on the Product Support pages under the following entry ID:
42784913 (http://support.automation.siemens.
com/WW/view/en/42784913)
You should also note the current information on the SIMATIC NET PC software on the product support pages under the entry ID:
12660737 (http://support.automation.siemens.
com/WW/view/en/12660737)
After the hardware installation
After installing the CP, your PG/PC automatically searches for a suitable driver.
1. Follow the instructions of the Hardware Wizard of Windows.
2. Do
not
activate the search for drivers on the Internet.
2.2 Uninstalling the SIMATIC NET PC software
Condition
The SIMATIC NET PC software is installed on the PG/PC.
Page 16
Software installation
2.2 Uninstalling the SIMATIC NET PC software
CP 5613 A3 / CP 5614 A3
16 Operating Instructions, 10/2012, C79000-G8976-C277-01
Procedure
NOTICE
The procedure recommended here deletes the entire SIMATIC NET PC software on the PG/PC not only the driver for the communications processor.
Uninstall the entire software package as described and recommended in the installation manual "SIMATIC NET, PC Software".
You will find the installation manual on the SIMATIC NET DVD or on the Product Support pages under the following entry ID:
42784913 (http://support.automation.siemens.
com/WW/view/en/42784913)
Page 17
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
17
Hardware installation
3
3.1 Safety notices
WARNING
Electric shock possible - work only when the power supply is off
Opening the PG/PC and plugging or pulling the communications processor is permitted only when the power is off.
Turn off your PG/PC and pull the power cable connector before you start the hardware installation.
CAUTION
Note the EC directives
Components can be damaged or destroyed by electrostatic discharge. When installing, keep to the rules for electrostatically sensitive devices (ESD).
Pick up components and modules only by their edges. Do not touch the pins or conductors.
Before opening the PG/PC, make sure that you discharge any electrostatic charge from your body. You can do this by touching metal parts on the back panel of the PG/PC pulling the power plug.
Make sure that you also discharge any electrostatic charge from tools you intend to use for the work on the PG/PC.
Do not operate the PG/PC with the housing open.
CAUTION
Firm mounting
The CP must sit firmly and uniformly in the slot. Check that the module sits firmly in the slot as described in the manual accompanying your PG/PC.
Note Oblique installation position is permitted
Some PG/PC designs require oblique installation of the CP. This is permitted.
Page 18
Hardware installation
3.2 Installing hardware
CP 5613 A3 / CP 5614 A3
18 Operating Instructions, 10/2012, C79000-G8976-C277-01
3.2 Installing hardware
Permitted number of communications processors in the PG/PC
The driver software supports a maximum of 4 CPs per PG/PC.
Automatic adaptation of the bus clock speed
The CP is designed for a bus clock speed of 66 MHz. If the CP is inserted in a PCI slot with a higher bus clock speed, the bus clock speed is adapted to the highest possible bus rate of the CP. Examples:
● The PCI slot is automatically reduced to a bus clock speed of 66 MHz.
● The bus clock speed of the CP is automatically reduced to 33 MHz if a module with a 33 MHz bus clock speed is connected.
Procedure
Note
First install the software First install the software before you insert the CP in the slot.
Activated plug and play function The plug and play function must be activated in the BIOS of your PG/PC.
Follow the steps outlined below when inserting the CP:
1. Turn off your PG/PC and pull the power cable connector.
2. Open the computer housing as described in the manual accompanying your PG/PC.
3. Remove the cover of a free PCI slot.
4. Remove the CP from its packaging.
5. Insert the CP in the PCI slot and secure it. Make sure that the CP is correctly inserted and secured.
6. Close the computer housing as described in the manual accompanying your PG/PC.
7. Insert the power plug into the socket again and turn your PG/PC on. The plug and play function of Windows automatically searches for a driver.
8. Follow the instructions of the Hardware Wizard of Windows. Do
not
activate the search for drivers on the Internet.
Page 19
Hardware installation
3.3 Hardware compatibility
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
19
3.3 Hardware compatibility
Compatibility with predecessor versions
The CP 5613 A3 can replace the following predecessor versions:
● CP 5613 A2
● CP 5613
The CP 5614 A3 can replace the following predecessor versions:
● CP 5613 A2 and CP 5614 A2
● CP 5613 and CP 5614
Note No configuration changes necessary
You can adopt the configuration of the previous CP. To do this, you simply need to reload the configuration.
Procedure for replacement
When replacing a module, follow the steps described in the section "Hardware installation (Page 17)".
Page 20
Hardware installation
3.3 Hardware compatibility
CP 5613 A3 / CP 5614 A3
20 Operating Instructions, 10/2012, C79000-G8976-C277-01
Page 21
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
21
Configuration
4
Configuring with STEP 7 or NCM PC
Create a suitable configuration for the CP in STEP 7 or NCM PC.
the procedure is described in detail in the configuration manual "Commissioning PC Stations“. You will find this document on the Product Support pages under the following entry ID:
13542666 (http://support.automation.siemens.
com/WW/view/en/13542666)
Compatibility during configuration
If there is not yet a CP 5613 A3 / CP 5614 A3 available in the hardware catalog of your STEP 7 version or NCM PC version, you can also select one of the following CPs for configuration:
● CP 5613 A2 / CP 5614 A2
● CP 5613/CP 5614
The CP 5613 A3 / CP 5614 A3 is downwards compatible with the configurations of the previous versions.
CAUTION
The DP slave configuration of a CP of the 5613 series is not compatible with the DP slave configuration of a CP from the 5614 series. This means, for example, that the DP slave configuration of a CP 5613 A3 must not be loaded on a CP 5614 A3 - and vice versa ­because the slave cannot work with this configuration.
Page 22
Configuration
CP 5613 A3 / CP 5614 A3
22 Operating Instructions, 10/2012, C79000-G8976-C277-01
Page 23
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
23
Technical specifications
5
Technical specifications CP 5613 A3 / CP 5614 A3 Connection to PROFIBUS
Amount
For CP 5613 A3
For CP 5614 A3
1 2
Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps,
93.75 kbps, 187.5 kbps, 500 kbps,
1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps
Design 9-pin D-sub female connector with screw
locking mechanism RS-485 (ungrounded within the SELV limits)
Properties Grounded cable shield
Floating interface signals Connection to PG/PC PCI, 33 MHz / 66 MHz, 32 bit
signal voltage: 5 VDC or 3.3 VDC
V 2.2 plug and play Electrical specifications of the PCI plug-in connector
Rated voltage 3.3 VDC and 12 VDC Permitted range 3.0 to 3.6 VDC
11.0 to 13.0 VDC
Operating voltage
Properties Safety extra low voltage (SELV) to EN
60950 Current consumption Typical
For CP 5613 A3
For CP 5614 A3
150 mA at 3.3 V and 250 mA at 12 V
180 mA at 3.3V and 280 mA at 12 V
Effective power loss Typical
For CP 5613 A3
For CP 5614 A3
3.5
3.9 W
Permitted ambient conditions
Temperature (EN 60068-2-1+2)
Temperature change max.
+5...+50°C
≤10 K/h
Rel. humidity (EN 60068-2-78)
≤ 85% at 30°C no condensation
Operating conditions
Rapid temperature change (EN 60068-2-14)
+5...+50°C, 5 cycles
Page 24
Technical specifications
CP 5613 A3 / CP 5614 A3
24 Operating Instructions, 10/2012, C79000-G8976-C277-01
Technical specifications CP 5613 A3 / CP 5614 A3
Temperature (EN 60068-2-1+2)
Temperature change max.
-20...+60°C ≤20 K/h
Rel. humidity (EN 60068-2-78)
≤ 95% at +25...+55°C no condensation
Storage and transportation conditions
Fast temperature change
to EN 60068-2-14
to EN 60068-2-30
-20...+60°C, 2 cycles +25...+55°C at 95% humidity
Vibration, operating (EN 60068-2-6)
Frequency 10...58 Hz Frequency 58...500 Hz number of cycles
0.075 mm amplitude 10 m/s2 Acceleration 10/axis
Shock, operating (EN 60068-2-27)
Half sine Time Number of shocks
50 m/s2 (5 g) 30 ms
100/axis Design, dimensions and weight Module format Flat module Short PCI card Weight
For CP 5613 A3
For CP 5614 A3
98 g
113 g
Dimensions (W x H x D)
For CP 5613 A3
For CP 5614 A3
18 x 107 x 125
18 x 107 x 125
Electromagnetic compatibility Emission
to EN 55022
to FCC
Class B
Class B
On signal cables
Surge to EN 610004-5
Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
Contact discharge to IEC 61000- 4-2
±6 kV
to radiated radio frequencies
to EN 61000-4-3
10 V/m at 80 MHz to 2 GHz 10 V/m, 50% ON duration at 900 MHz and
1.89 GHz
Immunity
to EN 61000-4-6
10 V/m, 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz
Page 25
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
25
Approvals
A
Note
The specified approvals apply only when the corresponding mark is printed on the communications processor.
Electromagnetic compatibility - EMC directive
The communications processor meets the requirements of the EC Directive:2004/108/EEC (EMC directive).
The communications processor is designed for use in the following areas:
Requirements Area of application
Emission Immunity
Residential areas, business and commercial operations, and small businesses
EN 61000-6-3 EN 61000-6-1
Industrial environment EN 61000-6-4 EN 61000-6-2
EC declaration of conformity
You will find the EC declaration of conformity for the communications processor on the Product Support pages under the following entry ID:
● For the CP 5613 A3: 58826788 (http://support.automation.siemens.
com/WW/view/en/58826788)
● For the CP 5614 A3 58826997 (http://support.automation.siemens.
com/WW/view/en/58826997)
Machinery directive
This communications processor is not a machine in the sense of the EC directive 2006/42/EEC (Machinery Directive). There is therefore no declaration of conformity relating to this EC Directive for the communications processor.
If the communications processor is part of the equipment of a machine, it must be included in the procedure for obtaining the declaration of conformity by the manufacturer of the machine.
C-TICK approval
The communications processor meets the requirements of the Australian AS/NZS 3548 standard.
Page 26
Approvals
CP 5613 A3 / CP 5614 A3
26 Operating Instructions, 10/2012, C79000-G8976-C277-01
CSA approval
The communications processor has an approval in accordance with the Canadian CAN/CSA C22.2 No. 60950-1 standard.
ICES conformity
The communications processor meets the requirements of the Canadian standard ICES-003. It is rated as a digital device of Class B ("Class B digital apparatus").
FCC approval
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
UL approval
The communications processor has an approval in accordance with the US standard UL 60950-1.
Page 27
CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01
27
Index
B
Bus clock speed, 18
C
Compatibility, 19, 21 Components of the product, 3 Configuration compatibilit
y, 21
C
onverting, 19
D
Documentation on the Internet, 3 D-sub female connector, 12
E
Electric shock, 17 Electrostatic charge, 17 ESD direc
tives, 17
L
LEDs, 13
M
Mounting, 17
N
NCM PC, 21 Number of CPs, permitted, 18
O
Oblique installation position, 17
P
PIN assignment, 12
PROFIBUS network, 12
R
Replacing, 19
S
SIMATIC NET documentation, 4 STEP 7, 21
Page 28
Index
CP 5613 A3 / CP 5614 A3
28 Operating Instructions, 10/2012, C79000-G8976-C277-01
Loading...