PC – PROFINET IRT
CP 1625 / CP 1625Dev
Standards, approvals and
EMC guidelines

Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
04/2018 Subject to change
Copyright © Siemens AG 2018.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
indicates that death or severe personal injury will result if proper precautions are not taken.
indicates that death or severe personal injury may result if proper precautions are not taken.
indicates that minor personal injury can result if proper precautions are not taken.
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
3
The CPs 1625 are PCIe expansion boards for SIMATIC IPCs. The cards have two LAN
interfaces.
The development board CP 1625Dev is specifically offered for customer-specific
PROFINET IRT interfaces.
The following table shows the different delivery variants:
1 x PN IRT PCIe interface with 2 ports
1 x PN IRT PCIe SOC1 Developer Board with 2 ports
Scope of validity of the documentation
This documentation is valid for the following products:
● CP 1625
● CP 1625Dev
"CP 1625Dev" means that the section applies
to the "CP 1625Dev".
"CP 1625" includes the "CP 1625" and the "CP 1625Dev".
Please also observe notes marked as follows:
Note
Notes contain important information on the produc
t, handling the product or on part of the
documentation to which you should pay particular attention.
The following names identified by ® and possibly some names without this identifier are
registered trademarks of Siemens AG:
SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 1625, CP 5612, CP 5613,
CP 5614, CP 5622
Siemens Automation Parts

Preface
CP 1625 / CP 1625Dev
4 Operating Instructions, 04/2018, A5E43075902-AA
Content of this documentation
These operating instructions contain information on the installation of the communications
processor CP 1625.
You can find additional information here:
● TIA Portal documentation
● Software Controller
You can find additional information on using the CP 1625 for development purposes here:
● PROFINET Driver Commissioning Manual
(https://support.industry.siemens.com/cs/ww/de/view/86655396/en
)
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support
(https://support.industry.siemens.com/cs/ww/en/view/109756564
) Internet pages
The documents listed below contain more detailed information on commissioning and using
the communications processors. You will find this documentation on the Product Support
pages on the Internet.
●
NET Industrial Ethernet/PROFINET System Manual
You will find detailed information on the structure of an industrial Ethernet network in this
document.
Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/27069465)
●
SIMATIC PROFINET System Description Manual
This provides you with basic knowledge of the following PROFINET IO topics: Network
components, data exchange and communication, PROFINET IO, component-based
automation, application example of PROFINET IO and component-based automation.
Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/19292127)
●
From PROFIBUS DP to PROFINET IO Manual
Read this document if you want to transfer an installed PROFIBUS system to a
PROFINET system.
Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/19289930)
You will find explanations of many specialist terms that are used in this documentation in the
SIMATIC NET glossary.
Entry ID: (http://support.automation.siemens.com/WW/view/en/50305045
)

Preface
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
5
Siemens Industry Online Support
You can find current information on the following topics quickly and easily here:
●
All the information and extensive know-how on your product, technical specifications,
FAQs, certificates, downloads, and manuals.
●
Tools and examples to solve your automation tasks – as well as function blocks,
performance information and videos.
●
Information about Industry Services, Field Services, Technical Support, spare parts and
training offers.
●
For answers and solutions concerning automation technology.
●
Your personal working area in Industry Online Support for messages, support queries,
and configurable documents.
This information is provided by the Siemens Industry Online Support in the Internet
(http://www.siemens.com/automation/service&support
).
Siemens Automation Parts

CP 1625 / CP 1625Dev
6 Operating Instructions, 04/2018, A5E43075902-AA
Preface ................................................................................................................................................... 3
1 Safety information ................................................................................................................................... 7
1.1 General safety instructions ...................................................................................................... 7
1.2 Security information ................................................................................................................. 8
2 Product overview .................................................................................................................................... 9
2.1 Hardware and software requirements ...................................................................................... 9
2.2 View of front panel ................................................................................................................. 10
2.3 Communications processor CP 1625 .................................................................................... 12
2.3.1 Interfaces and display elements ............................................................................................ 12
2.3.2 Properties ............................................................................................................................... 13
2.4 Communications processor CP 1625Dev .............................................................................. 14
2.4.1 Interfaces and display elements ............................................................................................ 14
2.4.2 Properties ............................................................................................................................... 18
3 Mounting ............................................................................................................................................... 19
3.1 Installing the holding plate ..................................................................................................... 19
4 Installing/connecting ............................................................................................................................. 20
4.1 Installing and connecting the CP 1625 .................................................................................. 20
5 Configuration ........................................................................................................................................ 22
6 Technical specifications ........................................................................................................................ 23
A Standards, approvals and EMC guidelines ............................................................................................ 25
A.1 Standards and approvals ....................................................................................................... 25
A.2 Electromagnetic compatibility ................................................................................................ 29
Index .................................................................................................................................................... 30

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
7
General safety instructions
Repairs
Incorrectly performed repairs may result in substantial damage to equipment or endanger
the user.
Only authorized personnel are permitted to repair the device.
Modules containing electrostatic sensitive devices (ESDs) can be identified by the following
label:
Strictly follow the guidelines mentioned below when handling modules which are sensitive to
ESD:
● Before working with modules with ESD, you need to ensure that you are free of
electrostatic charge (e.g. by touching a grounded object).
● All devices and tools must be free of static charge.
● Always pull the mains connector and disconnect the battery before installing or removing
modules which are sensitive to ESD.
● Handle modules fitted with ESDs only by their edges.
● Do not touch any connector pins or conductors on modules containing ESDs.
Siemens Automation Parts

Safety information
1.2 Security information
CP 1625 / CP 1625Dev
8 Operating Instructions, 04/2018, A5E43075902-AA
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens' products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be
connected to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or network
segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit (https://www.siemens.com/industrialsecurity
).
Siemens' products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers' exposure
to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (https://www.siemens.com/industrialsecurity
).

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
9
The following table provides an overview of the components of the CP 1625 and
CP 1625Dev:
x x Adhesive feet - 4 units
Terminal block for 24 V DC power supply
Advanced interface configuration
• X500: UART0
• X501: UART1
• X602: Interface for PROFINET certification
• X2200: Jumper for selecting boot source
• X1600: Jumper for selecting restart behavior
• X2000: Jumper for selecting power supply source
- x
Note
If the consignment is incomplete, contact your supplier or your local Siemens office.
Hardware and software requirements
Hardware requirement
The CP 1625 requires a short PCIe slot with master capabilities for operation.
The CP 1625 requires additional software for operation, e.g. CPU 1507S or a dedicated
SDK.
Siemens Automation Parts

Product overview
2.2 View of front panel
CP 1625 / CP 1625Dev
10 Operating Instructions, 04/2018, A5E43075902-AA
View of front panel
Connection elements
The following figure shows the front panel of the communications processor CP 1625:
Port 1 of the X1 interface
Port 2 of the X1 interface

Product overview
2.2 View of front panel
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
11
The connection of the CP 1625 to the LAN (Local Area Network) is made via one of the two
RJ45 sockets on the front panel of the communications processor.
The two sockets lead to the integrated real-time switch.
Note
Short-circuiting the LAN ports
If you accidentally short
-circuit the two LAN ports of the communications processor, this
f the network and the communications processor.
To restore the full scope of functions, you may need to reset the communications processor
or the Software Controller.
Two LEDs can be found in the frame of each RJ45 socket.
● The green LED lights up when a connection is established (Link LED).
● The yellow LED lights up during sending and receiving (Activity LED).
Siemens Automation Parts

Product overview
2.3 Communications processor CP 1625
CP 1625 / CP 1625Dev
12 Operating Instructions, 04/2018, A5E43075902-AA
Communications processor CP 1625
2.3.1
Interfaces and display elements
Appearance
The following figure shows the most important interfaces of the communications processor
CP 1625.
Figure 2-1 View of the CP 1625 interfaces

Product overview
2.3 Communications processor CP 1625
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
13
The CP 1625 is a PCIe module for the connection of PCs to Industrial Ethernet.
Note
The PROFINET ports must not be connected directly to the Internet.
The essential properties are as follows:
● Optimized for PROFINET IRT
● With Ethernet-Real-Time-ASIC SOC-1
● Two RJ45 sockets for connecting end devices or other network components
● Front LEDs on the RJ45 sockets for efficient self-diagnostics of connection and data
exchange (Link and Activity LED)
● Integrated 2-port real-time switch
● Automatic hardware detection is supported
The CP 1625 is intended for operation in Ethernet networks.
It also has the following features:
● Connections are designed for 100BASE-TX
● Data transmission speed of 100 Mbps in full/half duplex is supported
● Autonegotiation (can also be turned off)
● Autocrossing
Siemens Automation Parts

Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
14 Operating Instructions, 04/2018, A5E43075902-AA
Communications processor CP 1625Dev
2.4.1
Interfaces and display elements
Appearance
The following figure shows the most important interfaces, jumpers and LEDs of the
communications processor CP 1625Dev.
Connection for an external 24 V DC power supply
Interface for PROFINET certification
Jumper for selecting boot source
Jumper for selecting restart behavior
Jumper for selecting power supply source

Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
15
Interfaces X500 (UART0) and X501 (UART1)
The interface has the numbers ② and ③ in the figure above.
Connection for outgoing data (RS232 interface)
Connection for incoming data (RS232 interface)
If PROFINET certification of a device based on CP 1625Dev is required, the certification
authority uses the XPLL_OUT signal. The signal is available on the circuit board for
measuring purposes.
The interface is designated with the number
④ in the figure above.
Figure 2-4 X602

Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
16 Operating Instructions, 04/2018, A5E43075902-AA
Overview for use of the X1600, X2000 and X2200 interfaces/jumpers
At interface X1600 you use the jumper to set whether the CP 1625Dev should perform a
restart via the PCIe bus or be manually restarted.
The interface is designated with the number
⑥ in the figure above.
Figure 2-5 X1600
Pins 2 and 3 Manual restart (with external use of the

Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
17
At interface X2000 you use the jumper to set whether the CP 1625Dev should be operated in
an IPC or externally in Development mode.
The interface is designated with the number
⑦ in the figure above.
Figure 2-6 X2000
Power supply via PCIe bus
Power supply over X80 (with external use of the CP 1625Dev)
Damage to the IPC or the CP 1625Dev
Damage can occur if the jumper is inserted incorrectly on the X2000 interface and the IPC
is then connected to a 24 V DC power supply.
Set the position of the jumper on the X2000 interface according to the use of the CP 1625.
At interface X2200 you use the jumper to set whether the SOC1 is to boot from NAND flash.
The interface is designated with the number
⑤ in the figure above.
Figure 2-7 X2200
Boot from SPI flash (with use of the PCIe bus)
Boot from NAND flash (with external use of the CP 1625Dev)

Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
18 Operating Instructions, 04/2018, A5E43075902-AA
The CP 1625 is a PCIe module for the connection of PCs to Industrial Ethernet.
Note
The PROFINET ports must not be connected directly to the Internet.
The essential properties are as follows:
● Optimized for PROFINET IRT
● With Ethernet-Real-Time-ASIC SOC-1
● Two RJ45 sockets for connecting end devices or other network components
● Front LEDs on the RJ45 sockets for efficient self-diagnostics of connection and data
exchange (Link and Activity LED)
● Integrated 2-port real-time switch
● Automatic hardware detection is supported
● 24 V DC power supply for operation outside of the PC housing
● Two UART interfaces are available over the header
● Pushbutton for manually restarting the board
● Two LEDs on the board that signal an error or maintenance (Error and Maintenance LED)
● NAND flash
● SYNC Out signal available via the solder joint
● DDR2 memory technology up to 256 MB RAM
The CP 1625Dev has the "X80" interface for infeed of an external 24 V DC power supply.
-alone operation outside an IPC.
The CP 1625Dev is intended for operation in Ethernet networks.
It also has the following features:
● Connections are designed for 100BASE-TX
● Data transmission speed of 100 Mbps in full/half duplex is supported
● Autonegotiation (can also be turned off)
● Autocrossing

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
19
Installing the holding plate
For use in environments with increased mechanical loads, we recommend mounting of the
holding plate included in the scope of delivery. This improves the mechanical stability of the
plug-in connection. You fasten the outgoing cables to the holding plate with cable ties.
Figure 3-1 Correct mounting of holding plate
Siemens Automation Parts

CP 1625 / CP 1625Dev
20 Operating Instructions, 04/2018, A5E43075902-AA
Installing and connecting the CP 1625
Maximum configuration
A maximum of one CP 1625 is permitted per PC.
Prerequisites and requirements
Do not commission damaged parts
Only put undamaged parts into operation!
● Before installing the CP in your PC, read your PC manual, for example, the section
"Procedure for installing PCIe modules". Observe the instructions described in the
manual for your PC.
● If available, enable the plug-and-play mechanism in the BIOS of your PC.
● Before installation, make sure that the jumpers are set correctly on the CP 1625Dev. You
can find information on this in the section: Interfaces and display elements (Page 14
).
● The communications processor CP 1625 requires a PCIe slot with master capability.

Installing/connecting
4.1 Installing and connecting the CP 1625
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
21
Installing and connecting the CP 1625
Note
Installation only with power disconnected
Opening the PC and inserting or removing submodules is only permitted when the power is
disconnected.
Proceed as follows when installing and connecting the CP 1625:
1. Turn off your PC and pull out the power cable connector from the socket.
2. Open the PC housing as described in your PC manual.
3. Remove the cover of a free PCI slot in your PC.
4. Take the CP 1625 out of the packaging.
Note
When handling the communications processor, make sure that you do not touch the
connectors or the electronic components.
5. Insert the CP 1625 into the PCIe slot according to the instructions. Make sure that the
CP 1625 is inserted securely and evenly in the slot socket.
6. Close the PC housing as described in your PC manual.
7. Insert the connecting cable (TP) into the corresponding socket on the front panel of the
CP 1625.
8. Insert the power plug into the power socket again.
9. Switch on your PC.
Passive network components
You will find important notes on the use of passive network components in the document
"Industrial Ethernet / PROFINET Passive network components"
(https://support.industry.siemens.com/cs/ww/en/view/84922825
).
Siemens Automation Parts

CP 1625 / CP 1625Dev
22 Operating Instructions, 04/2018, A5E43075902-AA
After the communications processor is installed in the PC, it needs to be configured.
The communications processor CP 1625 is configured in the TIA Portal.
● TIA Portal ≥ V15 incl. Update 1
● S7-1500 Software Controller CPU 1507S (F) ≥ V2.5 is installed on the IPC
You can find additional information on configuration in the TIA Portal and in the
CPU 1505SP (F), CPU 1507S (F) Version 2 operating instructions
(http://support.automation.siemens.com/WW/view/en/109740725
).

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
23
Communications processor CP 1625
The following technical specifications apply to the communications processor CP 1625:
Connection to 10BaseT/100BaseTx
RJ-45 connector (2 units)
PCI-Express X1 V1.0a Plug & Play
Supply voltage externally via X80 (rated voltage)
PCI-Express voltage at +3.3 V
Permitted environmental conditions
Transportation and storage temperature

Technical specifications
CP 1625 / CP 1625Dev
24 Operating Instructions, 04/2018, A5E43075902-AA
Module format PC card, short PCIe format
• Standard height
• half length
Dimensions (H x W x D) in mm 111.2 x 21.6 x 167.15
Requirements for the external power supply
CP 1625 current consumption with the PC turned off
Damage to the IPC and/or the CP 1625Dev
If you connect a plugged CP 1625Dev communications processor to a 24 V DC power
supply, this can result in undefined states.
Damage to the IPC and/or the CP 1625Dev communications processor can occur as a
consequence.
Do
connect a 24 V DC power supply to a plugged CP 1625Dev communications
processor.
This product is intended for delivery with a UL-listed power supply unit designated as Class 2
with 24 V DC, 1 A (rated values) and a recommended ambient temperature of 45 °C.
Plug-in connector FMC 1.5 / 2-ST-3.81 (ships
with the product) or compatible
• Contact clearance: 3.81 mm
• Cable cross section: 0.2 mm
2
... 1.5 mm2
If supplied from a separate source, this must meet the requirements to comply with NEC
Class 2.

CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
25
Note
The specified approvals apply only when the corresponding mark is printed on the
communication
For environmentally friendly recycling and disposal of your old equipment, contact a certified
electronic waste disposal company and dispose of the equipment according to the applicable
regulations in your country.
Siemens Automation Parts

Standards, approvals and EMC guidelines
A.1 Standards and approvals
CP 1625 / CP 1625Dev
26 Operating Instructions, 04/2018, A5E43075902-AA
The communications processor CP 1625 meets the requirements and safety objectives of
the following guidelines and complies with the harmonized European standards (EN):
● 2014/34/EU ATEX Directive – "Directive of the European Parliament and of the Council of
February 26, 2014 on the harmonization of the laws of the Member States relating to
equipment and protective systems intended for use in potentially explosive atmospheres;
Official Journal of the European Union L96, 29/03/2014, pp. 309–356"
● 2014/30/EU "Electromagnetic Compatibility" (EMC Directive)
● 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and
electronic equipment" (RoHS Directive)
The EC declarations of conformity are available for the responsible authorities at:
Siemens AG
Digital Factory
Factory Automation
DF FA AS DH AMB
Postfach 1963
D-92209 Amberg
They are also available for download on the Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/
) Web pages, keyword "Declaration of
Conformity".
RCM (C-Tick) Declaration of conformity for Australia/New Zealand
The communications processor CP 1625 meets the requirements of the standards.
● AS/NZS 3548
● IEC 61000-6-3
The communications processor CP 1625 meets the requirements of the Canadian standard
ICES-003. The communications processor CP 1625 is classified as a "Class B digital
apparatus".

Standards, approvals and EMC guidelines
A.1 Standards and approvals
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
27
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Siemens AG is not responsible for any radio television interference caused by unauthorized
modifications of this equipment or the substitution or attachment of connecting cables and
equipment other than those specified by Siemens AG. The correction of interference caused
by such unauthorized modification, substitution or attachment will be the responsibility of the
user. The use of shielded I/O cables is required when connecting this equipment to any and
all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
UL 60950-1 2nd Edition, 2014-10-14 (Information Technology Equipment – Safety – Part 1:
General Requirements)
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment
– Safety – Part 1: General Requirements)
Siemens Automation Parts

Standards, approvals and EMC guidelines
A.1 Standards and approvals
CP 1625 / CP 1625Dev
28 Operating Instructions, 04/2018, A5E43075902-AA
According to EN 60079-15 (Electrical apparatus for potentially explosive atmospheres; Type
of protection "n") and EN 60079-0 (Electrical apparatus for potentially explosive gas
atmospheres - Part 0: General Requirements)
IECEx certificate number:
IEC 60079-0: 2011 (Ed. 6), + Corr.1.2012 + Corr.2.2013 and
EN 60079-15: 2010 (Ed. 4)
See product information: ATEX certification for CP 1625
(https://support.industry.siemens.com/cs/ww/en/view/109756565
)
Korea Certificate KCC-MSIP-REM-S49-PCCP
Note that this device corresponds to limit class A in terms of the emission of radio frequency
interference. This device can be used in all areas, except residential areas.
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기
바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다.
Marking for the Eurasian Customs Union
EAC (Eurasian Conformity)
Customs Union of Russia, Belarus and Kazakhstan
Declaration of conformity with the technical requirements of the Customs Union (TR CU).
The communications processor CP 1625 is based on the standard IEC 61158 Type 10.
The certificates for the markings and approvals can be found on the Internet under
Service&Support (https://support.industry.siemens.com/cs/ww/en/
).

Standards, approvals and EMC guidelines
A.2 Electromagnetic compatibility
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
29
Electromagnetic compatibility
Definition
Electromagnetic compatibility (EMC) is the ability of an electrical installation to function
satisfactorily in its electromagnetic environment without interfering with that environment.
The communications processor CP 1625 meets requirements including those of the EMC
legislation for the European single market. The prerequisite for this is that the
communications processor CP 1625 complies with the requirements and guidelines relating
to electrical configuration.
The communications processor meets the requirements of the EC Directive 2004/108/EC
(EMC directive).
Use in industrial environments
The communications processor CP 1625 is designed for use in industrial areas. It meets the
following standards for this type of use:
● Requirements for emitted interference EN 61000-6-4
● Requirements for immunity to interference EN 61000-6-2
Use in residential, business and commercial environments as well as light industry
The communications processor CP 1625 is designed for use in residential, business and
commercial environments as well as light industry. It meets the following standards for this
type of use:
● Requirements for emitted interference EN 61000-6-3
● Requirements for immunity to interference EN 61000-6-1
Siemens Automation Parts

CP 1625 / CP 1625Dev
30 Operating Instructions, 04/2018, A5E43075902-AA
Application
in industrial environments, 29
in residential, business and commercial
environments, light industry, 29
Approvals, 26
Configuring
Requirements, 22
Connecting
CP 1625, 21
CP 1625Dev, 21
CP to PC, 21
CP 1625
Ethernet operation, 13
Installation, 21
Interfaces, 12
Properties, 13
Scope of delivery, 9
Technical specifications, 23
Writing conventions, 3
CP 1625Dev
Ethernet operation, 18
Installation, 21
Interfaces, 14
Jumpers, 14
Power supply, 18
Properties, 18
Scope of delivery, 9
Technical specifications, 23
Writing conventions, 3
Delivery variants
CP 1625, 3
CP 1625Dev, 3
Electromagnetic compatibility (EMC), 29
EMC (Electromagnetic compatibility), 29
Front panel
Connection elements, 10
RJ45 sockets, 11
Holding plate
mounting, 19
Installation
CP 1625, 21
CP 1625Dev, 21
Passive network components, 21
Prerequisites and requirements, 20
Interfaces
CP 1625, 12
CP 1625Dev, 14
Maximum configuration, 20
mounting
Holding plate, 19
Requirements
Hardware, 9
Software, 9
Safety information
ESD guidelines, 7
Repairs, 7

Index
CP 1625 / CP 1625Dev
Operating Instructions, 04/2018, A5E43075902-AA
31
Scope, 3
Documentation, 3
Scope of delivery
CP 1625, 9
CP 1625Dev, 9
Specialist terms
SIMATIC NET glossary, 4
Standards, 26
Technical specifications
CP 1625, 23
CP 1625Dev, 23
Electromagnetic compatibility (EMC), 29
Standards and approval, 26
Trademarks, 3
Writing conventions, 3
Siemens Automation Parts