Siemens CP 1625, CP 1625Dev Operating Instructions Manual

Page 1
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC industrial PC
PC – PROFINET IRT CP 1625 / CP 1625Dev
Operating Instructions
04/2018
43075902-AA
Preface
Safety information
1
Product overview
2
Mounting
3
Installing/connecting
4
Configuration
5
Technical specifications
6
Standards, approvals and EMC guidelines
A
Siemens Automation Parts
Page 2
Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY
A5E43075902-AA
04/2018 Subject to change
Copyright © Siemens AG 2018. All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Page 3
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
3
Preface
The CPs 1625 are PCIe expansion boards for SIMATIC IPCs. The cards have two LAN interfaces.
The development board CP 1625Dev is specifically offered for customer-specific PROFINET IRT interfaces.
Delivery variants
The following table shows the different delivery variants:
Designation
Description
MLFB
CP 1625
1 x PN IRT PCIe interface with 2 ports
6ES7648-2CF10-1AA0
CP 1625Dev
1 x PN IRT PCIe SOC1 Developer Board with 2 ports
6ES7648-2CF10-1BA0
Scope of validity of the documentation
This documentation is valid for the following products:
CP 1625
CP 1625Dev
Conventions
"CP 1625Dev" means that the section applies
only
to the "CP 1625Dev".
"CP 1625" includes the "CP 1625" and the "CP 1625Dev".
Notes
Please also observe notes marked as follows:
Note
Notes contain important information on the produc
t, handling the product or on part of the
documentation to which you should pay particular attention.
Trademarks
The following names identified by ® and possibly some names without this identifier are registered trademarks of Siemens AG:
SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 1625, CP 5612, CP 5613, CP 5614, CP 5622
Siemens Automation Parts
Page 4
Preface
CP 1625 / CP 1625Dev
4 Operating Instructions, 04/2018, A5E43075902-AA
Content of this documentation
These operating instructions contain information on the installation of the communications processor CP 1625.
You can find additional information here:
TIA Portal documentation
Software Controller
You can find additional information on using the CP 1625 for development purposes here:
PROFINET Driver Commissioning Manual (https://support.industry.siemens.com/cs/ww/de/view/86655396/en
)
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support (https://support.industry.siemens.com/cs/ww/en/view/109756564
) Internet pages
Further documentation
The documents listed below contain more detailed information on commissioning and using the communications processors. You will find this documentation on the Product Support pages on the Internet.
NET Industrial Ethernet/PROFINET System Manual You will find detailed information on the structure of an industrial Ethernet network in this document. Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/27069465)
SIMATIC PROFINET System Description Manual This provides you with basic knowledge of the following PROFINET IO topics: Network components, data exchange and communication, PROFINET IO, component-based automation, application example of PROFINET IO and component-based automation. Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/19292127)
From PROFIBUS DP to PROFINET IO Manual Read this document if you want to transfer an installed PROFIBUS system to a PROFINET system. Entry ID: (
https://support.industry.siemens.com/cs/ww/en/view/19289930)
Specialist terms
You will find explanations of many specialist terms that are used in this documentation in the SIMATIC NET glossary.
Entry ID: (http://support.automation.siemens.com/WW/view/en/50305045
)
Page 5
Preface
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
5
Siemens Industry Online Support
You can find current information on the following topics quickly and easily here:
Product support
All the information and extensive know-how on your product, technical specifications, FAQs, certificates, downloads, and manuals.
Application examples
Tools and examples to solve your automation tasks – as well as function blocks, performance information and videos.
Services
Information about Industry Services, Field Services, Technical Support, spare parts and training offers.
Forums
For answers and solutions concerning automation technology.
mySupport
Your personal working area in Industry Online Support for messages, support queries, and configurable documents.
This information is provided by the Siemens Industry Online Support in the Internet (http://www.siemens.com/automation/service&support
).
Siemens Automation Parts
Page 6
CP 1625 / CP 1625Dev
6 Operating Instructions, 04/2018, A5E43075902-AA
Table of contents
Preface ................................................................................................................................................... 3
1 Safety information ................................................................................................................................... 7
1.1 General safety instructions ...................................................................................................... 7
1.2 Security information ................................................................................................................. 8
2 Product overview .................................................................................................................................... 9
2.1 Hardware and software requirements ...................................................................................... 9
2.2 View of front panel ................................................................................................................. 10
2.3 Communications processor CP 1625 .................................................................................... 12
2.3.1 Interfaces and display elements ............................................................................................ 12
2.3.2 Properties ............................................................................................................................... 13
2.4 Communications processor CP 1625Dev .............................................................................. 14
2.4.1 Interfaces and display elements ............................................................................................ 14
2.4.2 Properties ............................................................................................................................... 18
3 Mounting ............................................................................................................................................... 19
3.1 Installing the holding plate ..................................................................................................... 19
4 Installing/connecting ............................................................................................................................. 20
4.1 Installing and connecting the CP 1625 .................................................................................. 20
5 Configuration ........................................................................................................................................ 22
6 Technical specifications ........................................................................................................................ 23
A Standards, approvals and EMC guidelines ............................................................................................ 25
A.1 Standards and approvals ....................................................................................................... 25
A.2 Electromagnetic compatibility ................................................................................................ 29
Index .................................................................................................................................................... 30
Page 7
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
7
1
1.1
General safety instructions
Repairs
WARNING
Damage to the device
Incorrectly performed repairs may result in substantial damage to equipment or endanger the user.
Only authorized personnel are permitted to repair the device.
ESD guidelines
Modules containing electrostatic sensitive devices (ESDs) can be identified by the following label:
Strictly follow the guidelines mentioned below when handling modules which are sensitive to ESD:
Before working with modules with ESD, you need to ensure that you are free of
electrostatic charge (e.g. by touching a grounded object).
All devices and tools must be free of static charge.
Always pull the mains connector and disconnect the battery before installing or removing
modules which are sensitive to ESD.
Handle modules fitted with ESDs only by their edges.
Do not touch any connector pins or conductors on modules containing ESDs.
Siemens Automation Parts
Page 8
Safety information
1.2 Security information
CP 1625 / CP 1625Dev
8 Operating Instructions, 04/2018, A5E43075902-AA
1.2
Security information
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens' products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please visit (https://www.siemens.com/industrialsecurity
).
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (https://www.siemens.com/industrialsecurity
).
Page 9
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
9
2
Principle
The following table provides an overview of the components of the CP 1625 and CP 1625Dev:
Components
CP 1625
CP 1625Dev
Strain relief
x x Adhesive feet - 4 units
-
x
Terminal block for 24 V DC power supply
-
x
Advanced interface configuration
X500: UART0
X501: UART1
X602: Interface for PROFINET certification
X2200: Jumper for selecting boot source
X1600: Jumper for selecting restart behavior
X2000: Jumper for selecting power supply source
- x
Note
If the consignment is incomplete, contact your supplier or your local Siemens office.
2.1
Hardware and software requirements
Hardware requirement
The CP 1625 requires a short PCIe slot with master capabilities for operation.
Software requirement
The CP 1625 requires additional software for operation, e.g. CPU 1507S or a dedicated SDK.
Siemens Automation Parts
Page 10
Product overview
2.2 View of front panel
CP 1625 / CP 1625Dev
10 Operating Instructions, 04/2018, A5E43075902-AA
2.2
View of front panel
Connection elements
The following figure shows the front panel of the communications processor CP 1625:
Port 1 of the X1 interface
Port 2 of the X1 interface
Page 11
Product overview
2.2 View of front panel
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
11
RJ45 sockets
The connection of the CP 1625 to the LAN (Local Area Network) is made via one of the two RJ45 sockets on the front panel of the communications processor.
The two sockets lead to the integrated real-time switch.
Note Short-circuiting the LAN ports
If you accidentally short
-circuit the two LAN ports of the communications processor, this
leads to a malfunction o
f the network and the communications processor.
To restore the full scope of functions, you may need to reset the communications processor or the Software Controller.
LEDs of the RJ45 sockets
Two LEDs can be found in the frame of each RJ45 socket.
The green LED lights up when a connection is established (Link LED).
The yellow LED lights up during sending and receiving (Activity LED).
Siemens Automation Parts
Page 12
Product overview
2.3 Communications processor CP 1625
CP 1625 / CP 1625Dev
12 Operating Instructions, 04/2018, A5E43075902-AA
2.3
Communications processor CP 1625
2.3.1
Interfaces and display elements
Appearance
The following figure shows the most important interfaces of the communications processor CP 1625.
Figure 2-1 View of the CP 1625 interfaces
Page 13
Product overview
2.3 Communications processor CP 1625
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
13
2.3.2
Properties
Properties
The CP 1625 is a PCIe module for the connection of PCs to Industrial Ethernet.
Note
The PROFINET ports must not be connected directly to the Internet.
The essential properties are as follows:
Optimized for PROFINET IRT
With Ethernet-Real-Time-ASIC SOC-1
Two RJ45 sockets for connecting end devices or other network components
Front LEDs on the RJ45 sockets for efficient self-diagnostics of connection and data
exchange (Link and Activity LED)
Integrated 2-port real-time switch
Automatic hardware detection is supported
Ethernet
The CP 1625 is intended for operation in Ethernet networks.
It also has the following features:
Connections are designed for 100BASE-TX
Data transmission speed of 100 Mbps in full/half duplex is supported
Autonegotiation (can also be turned off)
Autocrossing
Siemens Automation Parts
Page 14
Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
14 Operating Instructions, 04/2018, A5E43075902-AA
2.4
Communications processor CP 1625Dev
2.4.1
Interfaces and display elements
Appearance
The following figure shows the most important interfaces, jumpers and LEDs of the communications processor CP 1625Dev.
X80
Connection for an external 24 V DC power supply
X500
UART0
X501
UART1
X602
Interface for PROFINET certification
X2200
Jumper for selecting boot source
X1600
Jumper for selecting restart behavior
X2000
Jumper for selecting power supply source
Figure 2-2 CP 1625Dev
Page 15
Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
15
Interfaces X500 (UART0) and X501 (UART1)
The interface has the numbers and in the figure above.
M
Ground
TXD
Connection for outgoing data (RS232 interface)
RXD
Connection for incoming data (RS232 interface)
Figure 2-3 X500-X501
Interface X602
If PROFINET certification of a device based on CP 1625Dev is required, the certification authority uses the XPLL_OUT signal. The signal is available on the circuit board for measuring purposes.
The interface is designated with the number
in the figure above.
Figure 2-4 X602
Signal
Pin
XPLL_OUT (SYNC Out)
2
GND (1M)
1
Siemens Automation Parts
Page 16
Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
16 Operating Instructions, 04/2018, A5E43075902-AA
Overview for use of the X1600, X2000 and X2200 interfaces/jumpers
Interface/jumper
CP 1625Dev connected
CP 1625Dev external
X1600
X2000
X2200
Interface/jumper X1600
At interface X1600 you use the jumper to set whether the CP 1625Dev should perform a restart via the PCIe bus or be manually restarted.
The interface is designated with the number
in the figure above.
Figure 2-5 X1600
Pin assignment
Description
Pins 1 and 2
Restart via PCIe bus
Pins 2 and 3 Manual restart (with external use of the
CP 1625Dev)
Page 17
Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
17
Interface/jumper X2000
At interface X2000 you use the jumper to set whether the CP 1625Dev should be operated in an IPC or externally in Development mode.
The interface is designated with the number
in the figure above.
Figure 2-6 X2000
Pin assignment
Description
Pins 1 and 2
Power supply via PCIe bus
Pins 2 and 3
Power supply over X80 (with external use of the CP 1625Dev)
NOTICE
Damage to the IPC or the CP 1625Dev
Damage can occur if the jumper is inserted incorrectly on the X2000 interface and the IPC is then connected to a 24 V DC power supply.
Set the position of the jumper on the X2000 interface according to the use of the CP 1625.
Interface/jumper X2200
At interface X2200 you use the jumper to set whether the SOC1 is to boot from NAND flash.
The interface is designated with the number
in the figure above.
Figure 2-7 X2200
Pin assignment
Description
Pins 1 and 2
Boot from SPI flash (with use of the PCIe bus)
Pins 2 and 3
Boot from NAND flash (with external use of the CP 1625Dev)
Siemens Automation Parts
Page 18
Product overview
2.4 Communications processor CP 1625Dev
CP 1625 / CP 1625Dev
18 Operating Instructions, 04/2018, A5E43075902-AA
2.4.2
Properties
The CP 1625 is a PCIe module for the connection of PCs to Industrial Ethernet.
Note
The PROFINET ports must not be connected directly to the Internet.
The essential properties are as follows:
Optimized for PROFINET IRT
With Ethernet-Real-Time-ASIC SOC-1
Two RJ45 sockets for connecting end devices or other network components
Front LEDs on the RJ45 sockets for efficient self-diagnostics of connection and data
exchange (Link and Activity LED)
Integrated 2-port real-time switch
Automatic hardware detection is supported
24 V DC power supply for operation outside of the PC housing
Two UART interfaces are available over the header
Pushbutton for manually restarting the board
Two LEDs on the board that signal an error or maintenance (Error and Maintenance LED)
NAND flash
SYNC Out signal available via the solder joint
DDR2 memory technology up to 256 MB RAM
External power supply
The CP 1625Dev has the "X80" interface for infeed of an external 24 V DC power supply.
Note
Only for stand
-alone operation outside an IPC.
Ethernet
The CP 1625Dev is intended for operation in Ethernet networks.
It also has the following features:
Connections are designed for 100BASE-TX
Data transmission speed of 100 Mbps in full/half duplex is supported
Autonegotiation (can also be turned off)
Autocrossing
Page 19
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
19
3
3.1
Installing the holding plate
For use in environments with increased mechanical loads, we recommend mounting of the holding plate included in the scope of delivery. This improves the mechanical stability of the plug-in connection. You fasten the outgoing cables to the holding plate with cable ties.
Figure 3-1 Correct mounting of holding plate
Siemens Automation Parts
Page 20
CP 1625 / CP 1625Dev
20 Operating Instructions, 04/2018, A5E43075902-AA
4
4.1
Installing and connecting the CP 1625
Maximum configuration
A maximum of one CP 1625 is permitted per PC.
Prerequisites and requirements
WARNING
Do not commission damaged parts
Only put undamaged parts into operation!
Before installing the CP in your PC, read your PC manual, for example, the section "Procedure for installing PCIe modules". Observe the instructions described in the manual for your PC.
If available, enable the plug-and-play mechanism in the BIOS of your PC.
Before installation, make sure that the jumpers are set correctly on the CP 1625Dev. You
can find information on this in the section: Interfaces and display elements (Page 14
).
The communications processor CP 1625 requires a PCIe slot with master capability.
Page 21
Installing/connecting
4.1 Installing and connecting the CP 1625
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
21
Installing and connecting the CP 1625
Note Installation only with power disconnected
Opening the PC and inserting or removing submodules is only permitted when the power is disconnected.
Proceed as follows when installing and connecting the CP 1625:
1. Turn off your PC and pull out the power cable connector from the socket.
2. Open the PC housing as described in your PC manual.
3. Remove the cover of a free PCI slot in your PC.
4. Take the CP 1625 out of the packaging.
Note
When handling the communications processor, make sure that you do not touch the connectors or the electronic components.
5. Insert the CP 1625 into the PCIe slot according to the instructions. Make sure that the
CP 1625 is inserted securely and evenly in the slot socket.
6. Close the PC housing as described in your PC manual.
7. Insert the connecting cable (TP) into the corresponding socket on the front panel of the
CP 1625.
8. Insert the power plug into the power socket again.
9. Switch on your PC.
Passive network components
You will find important notes on the use of passive network components in the document "Industrial Ethernet / PROFINET Passive network components" (https://support.industry.siemens.com/cs/ww/en/view/84922825
).
Siemens Automation Parts
Page 22
CP 1625 / CP 1625Dev
22 Operating Instructions, 04/2018, A5E43075902-AA
5
After the communications processor is installed in the PC, it needs to be configured.
The communications processor CP 1625 is configured in the TIA Portal.
Requirements
● TIA Portal ≥ V15 incl. Update 1
S7-1500 Software Controller CPU 1507S (F) ≥ V2.5 is installed on the IPC
Reference
You can find additional information on configuration in the TIA Portal and in the CPU 1505SP (F), CPU 1507S (F) Version 2 operating instructions (http://support.automation.siemens.com/WW/view/en/109740725
).
Page 23
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
23
6
Communications processor CP 1625
The following technical specifications apply to the communications processor CP 1625:
Data transfer
Transmission rate
100 Mbps
Interfaces
Connection to 10BaseT/100BaseTx
RJ-45 connector (2 units)
Connection to PC
PCI-Express X1 V1.0a Plug & Play
Voltage
Power supply PCI-Express
3.3 VDC ± 9 %
Supply voltage externally via X80 (rated voltage)
19.2 V DC to 28.8 V DC
Current consumption
PCI-Express voltage at +3.3 V
Maximum 1.2 A
External supply at +24 V
Maximum 250 mA
Permitted environmental conditions
Operating temperature
+0 °C ... +45 °C
Transportation and storage temperature
-20 °C ... +70 °C
Siemens Automation Parts
Page 24
Technical specifications
CP 1625 / CP 1625Dev
24 Operating Instructions, 04/2018, A5E43075902-AA
Construction
Module format PC card, short PCIe format
Standard height
half length
Dimensions (H x W x D) in mm 111.2 x 21.6 x 167.15
Weight
110 g
Space required PCIe slot
Requirements for the external power supply
Electrical isolation
required
Voltage range
19.2 V DC to 28.8 V DC
CP 1625 current consumption with the PC turned off
Approx. 0.25 A at 24 V
NOTICE
Damage to the IPC and/or the CP 1625Dev
If you connect a plugged CP 1625Dev communications processor to a 24 V DC power supply, this can result in undefined states.
Damage to the IPC and/or the CP 1625Dev communications processor can occur as a consequence.
Do
not
connect a 24 V DC power supply to a plugged CP 1625Dev communications
processor.
This product is intended for delivery with a UL-listed power supply unit designated as Class 2 with 24 V DC, 1 A (rated values) and a recommended ambient temperature of 45 °C.
Power supply
Plug-in connector FMC 1.5 / 2-ST-3.81 (ships with the product) or compatible
Contact clearance: 3.81 mm
Cable cross section: 0.2 mm
2
... 1.5 mm2
WARNING
External supply
If supplied from a separate source, this must meet the requirements to comply with NEC Class 2.
Page 25
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
25
A
A.1
Standards and approvals
Note
The specified approvals apply only when the corresponding mark is printed on the communication
s processor.
Recycling and disposal
For environmentally friendly recycling and disposal of your old equipment, contact a certified electronic waste disposal company and dispose of the equipment according to the applicable regulations in your country.
Siemens Automation Parts
Page 26
Standards, approvals and EMC guidelines A.1 Standards and approvals
CP 1625 / CP 1625Dev
26 Operating Instructions, 04/2018, A5E43075902-AA
CE marking
The communications processor CP 1625 meets the requirements and safety objectives of the following guidelines and complies with the harmonized European standards (EN):
2014/34/EU ATEX Directive – "Directive of the European Parliament and of the Council of February 26, 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres; Official Journal of the European Union L96, 29/03/2014, pp. 309–356"
2014/30/EU "Electromagnetic Compatibility" (EMC Directive)
2011/65/EU "Restriction of the use of certain hazardous substances in electrical and
electronic equipment" (RoHS Directive)
The EC declarations of conformity are available for the responsible authorities at:
Siemens AG Digital Factory Factory Automation DF FA AS DH AMB Postfach 1963 D-92209 Amberg
They are also available for download on the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/
) Web pages, keyword "Declaration of
Conformity".
RCM (C-Tick) Declaration of conformity for Australia/New Zealand
The communications processor CP 1625 meets the requirements of the standards.
AS/NZS 3548
IEC 61000-6-3
ICES
The communications processor CP 1625 meets the requirements of the Canadian standard ICES-003. The communications processor CP 1625 is classified as a "Class B digital apparatus".
Page 27
Standards, approvals and EMC guidelines A.1 Standards and approvals
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
27
FCC approval
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
UL
UL file E498473
UL 60950-1 2nd Edition, 2014-10-14 (Information Technology Equipment – Safety – Part 1: General Requirements)
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment – Safety – Part 1: General Requirements)
Siemens Automation Parts
Page 28
Standards, approvals and EMC guidelines A.1 Standards and approvals
CP 1625 / CP 1625Dev
28 Operating Instructions, 04/2018, A5E43075902-AA
ATEX approval
According to EN 60079-15 (Electrical apparatus for potentially explosive atmospheres; Type of protection "n") and EN 60079-0 (Electrical apparatus for potentially explosive gas atmospheres - Part 0: General Requirements)
II 3 G Ex nA IIC Gc
ATEX certificate number:
DEKRA 18ATEX0002 U
IECEx certificate number:
DEK 18.0001U
IECEx standards:
IEC 60079-0: 2011 (Ed. 6), + Corr.1.2012 + Corr.2.2013 and
EN 60079-15: 2010 (Ed. 4)
Code:
Ex nA IIC Gc
See product information: ATEX certification for CP 1625 (https://support.industry.siemens.com/cs/ww/en/view/109756565
)
Korea Certificate KCC-MSIP-REM-S49-PCCP
Note that this device corresponds to limit class A in terms of the emission of radio frequency interference. This device can be used in all areas, except residential areas.
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다.
Marking for the Eurasian Customs Union
EAC (Eurasian Conformity)
Customs Union of Russia, Belarus and Kazakhstan
Declaration of conformity with the technical requirements of the Customs Union (TR CU).
PROFINET standard
The communications processor CP 1625 is based on the standard IEC 61158 Type 10.
Reference
The certificates for the markings and approvals can be found on the Internet under Service&Support (https://support.industry.siemens.com/cs/ww/en/
).
Page 29
Standards, approvals and EMC guidelines A.2 Electromagnetic compatibility
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
29
A.2
Electromagnetic compatibility
Definition
Electromagnetic compatibility (EMC) is the ability of an electrical installation to function satisfactorily in its electromagnetic environment without interfering with that environment.
The communications processor CP 1625 meets requirements including those of the EMC legislation for the European single market. The prerequisite for this is that the communications processor CP 1625 complies with the requirements and guidelines relating to electrical configuration.
EMC directive
The communications processor meets the requirements of the EC Directive 2004/108/EC (EMC directive).
Use in industrial environments
The communications processor CP 1625 is designed for use in industrial areas. It meets the following standards for this type of use:
Requirements for emitted interference EN 61000-6-4
Requirements for immunity to interference EN 61000-6-2
Use in residential, business and commercial environments as well as light industry
The communications processor CP 1625 is designed for use in residential, business and commercial environments as well as light industry. It meets the following standards for this type of use:
Requirements for emitted interference EN 61000-6-3
Requirements for immunity to interference EN 61000-6-1
Siemens Automation Parts
Page 30
CP 1625 / CP 1625Dev
30 Operating Instructions, 04/2018, A5E43075902-AA
A
Application
in industrial environments, 29 in residential, business and commercial environments, light industry, 29
Approvals, 26
C
Configuring
Requirements, 22
Connecting
CP 1625, 21 CP 1625Dev, 21 CP to PC, 21
CP 1625
Ethernet operation, 13 Installation, 21 Interfaces, 12 Properties, 13 Scope of delivery, 9 Technical specifications, 23 Writing conventions, 3
CP 1625Dev
Ethernet operation, 18 Installation, 21 Interfaces, 14 Jumpers, 14 Power supply, 18 Properties, 18 Scope of delivery, 9 Technical specifications, 23 Writing conventions, 3
D
Delivery variants
CP 1625, 3 CP 1625Dev, 3
E
Electromagnetic compatibility (EMC), 29 EMC (Electromagnetic compatibility), 29
F
Front panel
Connection elements, 10 RJ45 sockets, 11
H
Holding plate
mounting, 19
I
Installation
CP 1625, 21 CP 1625Dev, 21 Passive network components, 21 Prerequisites and requirements, 20
Interfaces
CP 1625, 12 CP 1625Dev, 14
J
Jumpers
CP 1625Dev, 14
M
Maximum configuration, 20 mounting
Holding plate, 19
R
Requirements
Hardware, 9 Software, 9
S
Safety information
ESD guidelines, 7 Repairs, 7
Page 31
Index
CP 1625 / CP 1625Dev Operating Instructions, 04/2018, A5E43075902-AA
31
Scope, 3
Documentation, 3
Scope of delivery
CP 1625, 9 CP 1625Dev, 9
Specialist terms
SIMATIC NET glossary, 4
Standards, 26
T
Technical specifications
CP 1625, 23 CP 1625Dev, 23 Electromagnetic compatibility (EMC), 29 Standards and approval, 26
Trademarks, 3
W
Writing conventions, 3
Siemens Automation Parts
Loading...