About this document
This document provides you with information on the SIEMENS CCIC1410 IP
Cameras.
Instructions for installation and setup can be found in the Installation Guide.
Trademarks
SIEMENS CCIC1410 is a trademark of Fire & Security Products GmbH & Co. oHG.
Microsoft is a registered trademark and Windows a trademark of Microsoft
Corporation.
All other product or company names mentioned in this document are trademarks or
registered trademarks of their respective owners and are used only for purposes of
identification or description.
Contacting us
If you have questions or suggestions regarding the product or this documentation,
please contact our Customer Support centre:
Intranet:
Internet:
Customer Support Center
Worldwide contacts
Email: fs.support.sbt@siemens.com
Tel.: +49 89 9221 8000
Training courses
Siemens Fire & Security Products provides training courses for all products.
11.1 Using the CCIC1410 Homepage ............................................................90
11.2 Using the CCIC1410 Installation Wizard.................................................90
12 Index .......................................................................................................94
4
Siemens Building Technologies
Fire Safety & Security Products 05.2009
1 Safety
1.1 Target readers
Safety
Target readers Qualification Activity Condition of the
End user Has working knowledge
of computers.
Instruction by technical
specialists is necessary.
Service personnel Technical training for
electrical installations.
1.2 General safety precautions
zRead the general safety precautions before installing, configuring and operating
the device.
zPlease also read the safety precautions for the devices that are operated by the
software. Further information on this can be found in the Manuals for the
respective devices.
z Keep this document for reference.
z Always pass this document on together with the product.
z Please also take into account any additional country-specific, local safety
standards or regulations concerning project planning, operation and disposal of
the product.
zDo not attempt to service or modify this device yourself. Refer this work to
qualified service personnel.
zThe unit operates on frequencies that are approved for use in the European
Union. When used outside the EU, the national regulations for the use of
frequencies must be observed.
Performs only the
procedures for proper
operation of the
product.
Checks the product at
regular intervals to
ensure that it is in good
working order and
performs service work.
product
The product is installed
and configured.
Product already in use
and requiring servicing.
1.2.1 Transport
Damage during transport
z Keep the packaging material for future transportation.
z Do not expose the device to mechanical vibrations or shocks.
1.2.2 Installation of the device
zIt is recommended that all preparatory work (e.g. fitting of accessories) be
carried out in a workshop prior to final installation.
z Refer installation to a qualified electrician.
z When handling modules that are susceptible to electrostatic discharge, please
observe the ESD guidelines.
Siemens Building Technologies
Fire Safety & Security Products 05.2009
5
Safety
Radio interference with other devices in the environment
zIn France, it is not allowed to use the CCIC1410-LAW outside buildings and on
the channels 10 – 13.
zThe unit operates on frequencies that are approved for use in the European
Union. When used outside the EU, the national regulations for the use of
frequencies must be observed.
Damage due to unsuitable mounting location
zThe environmental conditions recommended by the manufacturer must be
observed.
zDo not operate the device close to sources of powerful electromagnetic
radiation.
z Do not operate the device in dusty places.
z The device should only be used for indoor applications.
z Do not expose the device to mechanical vibrations or shocks.
z Protect the device against moisture.
Danger of electrical shock due to incorrect connection
z Connect the device only to a limited power source.
z This device is designed to work with 5 V DC-systems. Do not connect the device
to any other power systems.
Risk of cable damage due to stress
z Make sure that all outgoing cables and wires are sufficiently strain-relieved.
z Make sure that cables are not under stress, kinked or damaged.
1.2.3 Service and maintenance
zDo not attempt to service or modify this device yourself. Refer this work to
qualified service personnel.
1.2.4 Cleaning of the device
Do not touch the imaging surface of the sensor. Use a soft cloth moistened with
alcohol to clean the surface if it is touched accidentally.
1.2.5 Software
Damage during transport
z Always transport the CD in the case it originally came in.
Data loss after software update
z Make sure to backup all data before updating the software.
Damage due to improper handling
z Protect the CD from scratching.
z To clean the CD use a soft dry cloth.
6
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Damage due to improper storage of CD
z Always store the CD in its protective case.
z Keep the CD in an environment with a relative humidity of 10 – 90 %.
z Keep the CD between -5 and +55 °C.
z Do not store the CD in dusty places.
z Do not keep the CD close to sources of magnetic radiation.
z Protect the CD from moisture.
z Protect the CD from direct sunlight.
1.3 CMOS characteristics
The following conditions may be observed when using a CMOS camera. These are
inherent in the design and do not stem from any fault in the camera itself.
Vertical smear This phenomenon occurs when viewing a very bright object.
Patterned noise This is a fixed pattern, which may appear over the entire monitor screen
Jagged picture When viewing stripes, straight lines, or similar patterns, the image on
Safety
when the camera is operated at high temperatures or in low illumination
environments.
the screen may appear jagged.
1.4 Meaning of the written warning notices
The severity of a hazard is indicated by the following written warning notices.
Signal word Type of risk
DANGER Imminent danger of death or severe bodily injury
WARNING Possible danger of death or severe bodily harm
CAUTION There is a risk of minor to medium injuries or damage to property
IMPORTANT Malfunctioning may result
1.5 Meaning of the hazard symbols
The nature of the hazard is indicated by icons.
Warning of a hazard
Warning of dangerous electrical voltage
NOTE
Important information.
Siemens Building Technologies
Fire Safety & Security Products 05.2009
7
Directives and standards
2 Directives and standards
The product complies with the requirements of the following EU directives.
The EU declaration of conformity is available from:
Compliance with the European Directive 2006/95/EC has been proven by testing
according to the following standard:
Safety: EN 60950-1
For CCIC1410-LAW
zEuropean Directive 1999/5/EC “Radio and telecommunications terminal
equipment”
Compliance with the European Directive 2006/95/EC has been proven by testing
according to the following standard:
Safety: EN 60950-1
Human exposure to electromagnetic fields: EN 50371
Electromagnetic Compatibility and Radio spectrum Matters: EN 301489-1,
EN 301489-17 and EN 300328
8
Siemens Building Technologies
Fire Safety & Security Products 05.2009
2.1 National restrictions
The CCIC1410-LAW can be operated in the following European countries:
AT, BE, BG, CH, CY, CZ, DK, DE, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, LV, LI,
LT, LU, MT, NL, NO, PL, PT, RO, SE, SK, SI, TR.
The unit operates on frequencies that are approved for use in the European Union.
When used outside the EU, the national regulations for the use of frequencies must
be observed.
2.2 Restrictions for France
In France, it is not allowed to use the CCIC1410-LAW out of buildings and on the
channels 10 – 13.
Directives and standards
Siemens Building Technologies
Fire Safety & Security Products 05.2009
9
Directives and standards
2.3 Declaration of conformity
10
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Event notification Notification via HTTP, SMTP, FTP
Event memory 600 KB for MPEG4 pictures
Privacy -
Local switching off of video and audio for privacy
reasons (configurable in setup)
Web browser IE browser 6.0 or above
I/O connector
Network port RJ45 with control LEDs: system activity and network link
Alarm connector - 1x alarm in /1 x alarm out
LED indicators Status, network link Status, network link, privacy
Power supply
Power requirements 5 V DC (PSU included)
Power consumption < 5 W < 5 W < 7 W
Environment
Ambient temperature,
operating
0 – 40 ºC
Relative humidity 20 – 80 %, no condensation
Ambient temperature,
storage
0 – 60 ºC
Mechanism
Dimensions (W x H x D) 87 x 88 x 32 mm
Weight 0.128 kg 0.128 kg 0.130 kg
12
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Ordering data
4 Ordering data
Type Item No. Description Weight
CCIC1410-L S54561-C90-A1 CCIC1410-L 1/4" IP Camera VGA Colour 128 g
CCIC1410-LA S54561-C90-A2 CCIC1410-LA 1/4" IP Camera Colour Audio 128 g
CCIC1410-LAW S54561-C90-A3 CCIC1410-LAW 1/4" IP Camera Colour WLAN 130 g
5 Package contents
z 1 x SIEMENS CCIC1410 IP Camera
z 1 x Documentation CD
z 1 x Utilities CD
z 1 x Installation instruction (English, German)
z 1 x Installation instruction (French, Spanish, Italian)
z 1 x Power adapter
z 1 x Wall/Ceiling bracket
z 1 x Ethernet cable (1:1, 2 m)
z 2 x Wall plugs
z 2 x Mounting screw
13
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Description of the equipment
6 Description of the equipment
SIEMENS CCIC1410 IP cameras are easy-to-use network cameras for security
applications in offices and residential areas, specifically designed with a compact
exterior. Despite its ultra-compact size, the camera incorporates many advanced
features to meet IT security requirements.
The embedded SOC enables the camera to simultaneously deliver dual streams in
MPEG4 and MJPEG with different video resolution and quality upon different
devices, such as digital video recorders SISTORE MX HVR/NVS, PC or 3G cell
phones. SIEMENS CCIC1410-LAW also supports built-in 802.11b/g WLAN
capability, which prevents tangled cables.
Additionally CCIC1410-LA and -LAW come with a pushbutton on the front side for
privacy use. The user can manually stop the operation of video monitoring with
ease to protect from unwanted observation. This functionality can be activated or
deactivated by system administrator only.
6.1 Versions of the camera
The SIEMENS CCIC1410 IP cameras are available in the following versions:
z SIEMENS CCIC1410-L – Video
z SIEMENS CCIC1410-LA – Video and Audio
z SIEMENS CCIC1410-LAW – Video, Audio and Wireless LAN
14
Siemens Building Technologies
Fire Safety & Security Products 05.2009
6.3 Pin definitions of input/output (only CCIC1410-LA, -LAW)
This network camera provides a general input/output terminal block which is used
to connect external input / output devices. The pin definitions are described below.
4312
1
2
3
4
Power
Digital output
Digital input
Ground
15
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Description of the equipment
6.4 Connection method
The connection method is shown in the illustration below.
6.5 LED status
The LED indicates the status of the network camera.
LED status Privacy button Description
Solid red Solid blue Power is being supplied to the camera.
Blinking red Blinking blue The camera is booting up.
Solid red Off The camera is trying to obtain an IP address.
Blinking green Off An IP address has been successfully assigned to the camera and
the camera is working.
Blinking red Off Firmware upgrade is in progress.
Blinking green and red Off The camera settings are being restored.
16
Siemens Building Technologies
Fire Safety & Security Products 05.2009
6.6 Hardware reset
There is a reset button on the back cover of the network camera (see chapter 6.2
Front and rear views of the camera, No. 5). It is used to reboot the network camera
or to reset the network camera to the factory default configuration. Depending on
the functional problem, rebooting may set the network camera back to normal
state. If the problem remains after rebooting, restore the network camera settings
to the factory default and install the software again.
Reboot:
Press and release the reset button. The status LED on the front will blink red.
Restore:
Press the reset button continuously until the status LED on the front blinks in red
and green simultaneously. Note that all settings will be reset to factory default.
Description of the equipment
17
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Installation
7 Installation
7.1 Network setup
This section explains how to configure the network camera for Internet connection.
1. If you have external devices such as sensors and alarms, connect them to the
general I/O terminal block.
2. Connect the camera to a switch/hub using an Ethernet cable. Use a Category
5 cross cable when the network camera is directly connected to a PC.
3. Connect the supplied power adapter from the network camera to a power
outlet.
4312
There are several ways to set up the network camera via the Internet:
z Set up the network camera behind a router.
z Utilize a static IP.
z Use PPPoE.
18
Siemens Building Technologies
Fire Safety & Security Products 05.2009
7.1.1 Internet connection via a router
Before setting up the network camera over the Internet, make sure you have a
router, and follow the steps below.
1. Connect your network camera behind a router. The Internet environment is
illustrated as below. For information on how to obtain an IP address, see
chapter
8.5: Network settings.
Installation
2. In this example, the Local Area Network (LAN) IP address of your network
camera is 192.168.0.3. Please forward the following ports for the network
camera on the router.
– HTTP port
– RTSP port
– RTP port for audio
– RTCP port for audio
– RTP port for video
– RTCP port for video
If you have changed the port numbers on the Network page, please open the
ports accordingly on your router. For information on how to forward ports on
the router, please refer to the user’s manual of your router.
3. Find out the public IP address of your router provided by your ISP (Internet
Service Provider). Use the public IP and the secondary HTTP port to access
the network camera from the Internet (see chapter
9.7.1: Network type).
19
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Installation
7.1.2 Internet connection with static IP
Choose this connection type if you are required to use a static IP for the network
camera and proceed as follows.
1. Set up the network camera in the LAN (see chapter
2. Go to Configuration > Network > Network Type.
3. Select LAN > Use fixed IP address.
4. Enter the static IP, Subnet mask, Default router, Primary DNS provided by
your ISP.
8.5.2).
7.1.3 Internet connection via PPPoE (Point-to-Point over Ethernet)
Choose this connection type if you are connected to the Internet via a DSL Line
(see chapter
8.5.1: PPPoE setting).
20
Siemens Building Technologies
Fire Safety & Security Products 05.2009
8 CCIC1410 Installation Wizard
The initial setup of the CCIC1410 network camera is done with the
CCIC1410 Installation Wizard. For the first use of the CCIC1410 Installation
Wizard, just follow the steps of the Wizard Tool.
The CCIC1410 Installation Wizard is a software that helps you installing your
CCIC1410 camera.
You first need to set up the Installation Wizard on your PC, then you can start the
configuration.
8.1 Set up the CCIC1410 Installation Wizard
1. Put the installation disk into the CD-ROM drive of your PC.
Î The installation should start automatically.
2. If the installation does not start, click Start in the lower left corner of your
screen, open My Computer and double-click on the CD-ROM icon.
ÎThe following window will appear.
CCIC1410 Installation Wizard
3. Please read the license agreement first.
4. Click on I Agree to continue the installation process.
ÎThe following window will appear.
21
Siemens Building Technologies
Fire Safety & Security Products 05.2009
CCIC1410 Installation Wizard
5. Select the additional component you want to install. The component Create
shortcut on desktop will create a shortcut on the desktop. This will make it
more convenient for you to launch Install Wizard 2.
6. Click Next.
ÎThe following window will appear.
7. Select an installation directory for this application software.
8. Click Install.
ÎThe install system will install the CCIC1410 Installation Wizard to your
computer, and a progress bar will be displayed on the dialog.
22
Siemens Building Technologies
Fire Safety & Security Products 05.2009
9. Once the installation is completed, click Close.
1. Use the shortcut on your desktop to open the CCIC1410 Installation Wizard.
ÎThe user interface of the CCIC1410 Installation Wizard appears.
23
Siemens Building Technologies
Fire Safety & Security Products 05.2009
CCIC1410 Installation Wizard
8.3 User interface of the CCIC1410 Installation Wizard
On the left side, several function buttons are situated, e.g. the Manual Setup
button, etc. When you click on the arrow button, you will see more advanced
functional buttons.
8.3.1 Select a device for the configuration
1. Open the CCIC1410 Installation Wizard, see chapter 8.2.
2. Select a device in the device list by clicking on it.
ÎThe three buttons on the left (“Manual Setup”, “Firmware Upgrade”, and
“Restore Default”) will not be enabled until at least one device is selected.
24
Siemens Building Technologies
Fire Safety & Security Products 05.2009
8.3.2 Refreshing the device list (and linking to the devices)
Clicking on the Refresh Devices button will refresh the device list and search for
all devices on the LAN again. Refreshing the device list will take several seconds.
If you want to link to your device, double-clicking it on your device list will lead you
to the browser for operating your device.
8.4 System settings
8.4.1 Open the system settings page
1. Select a device for which you want to change the settings in the device list
(see chapter
2. Click the Manual Setup button on the left side.
ÎWhen one device is selected in the device list, the Manual Setup button
will be enabled.
Î CCIC1410 Installation Wizard will try to connect to the selected device.
Î If the authentication fails, a dialog will pop up asking you for the correct
password.
8.3.1: Select a device for the configuration).
CCIC1410 Installation Wizard
Fig. 1 Authentication dialog
ÎIf an incorrect password is entered three times, the CCIC1410 Installation
Wizard will show you a warning dialog window and abort the connection to
the selected device.
ÎWhen the connection to the selected device has been established, the
CCIC1410 Installation Wizard will switch to the system settings page.
25
Siemens Building Technologies
Fire Safety & Security Products 05.2009
CCIC1410 Installation Wizard
Fig. 2 System settings page
8.4.2 Change host name
1. Open the system settings page (see chapter 8.4.1).
The Hostname is used for the homepage title of the main page and is displayed as
the title in the video window of the main page. The maximum string length is 40
characters or 20 characters in double-byte character systems like Chinese or
Japanese.
8.4.3 Change administrator password
1. Open the system settings page (see chapter 8.4.1).
To change the administrator’s password, enter the new password in both the
Password and the Confirm Password text boxes identically. The text entered will
be displayed as asterisks for security purposes. The maximum password length
depends on the server you are connected to.
26
Siemens Building Technologies
Fire Safety & Security Products 05.2009
8.4.4 Adjust date and time
1. Open the system settings page (see chapter 8.4.1).
There are three ways to adjust the system date and time settings:
z"Synchronize with computer time":
The easiest way is synchronize the device with your computer time.
z“Set date and time manually”:
Set the date and time manually by entering new values. Note the format in the
respective fields while typing.
z“Synchronize to network time server automatically”:
The device is automatically synchronized with timeservers over the Internet
every hour.
If you want to keep the current date and time, select “Keep current date and time”.
CCIC1410 Installation Wizard
Fig. 3 Date/Time setup
8.5 Network settings
8.5.1 PPPoE setting
1. Open the system settings page, see chapter 8.4.1.
2. Click Next.
Î The following dialog window appears:
3. Click Yes.
ÎYou will be led to the PPPoE setting page. On this page, you can enter the
“PPPoE username” and “PPPoE password” provided by your ISP, and then
the server will be set to PPPoE mode rather than LAN mode when the
setup is completed. If you do not have the account information, please
contact your ISP.
ÎThe PPPoE setting page appears.
27
Siemens Building Technologies
Fire Safety & Security Products 05.2009
CCIC1410 Installation Wizard
8.5.2 LAN setting
Fig. 4 PPPoE setting page
4. Enter the account information.
5. Click Next and follow the pages of the Installation Wizard.
1. Open the system settings page (see chapter 8.4.1).
2. Click Next.
Î The following dialog window appears:
3. Click No.
ÎThe Network Settings page appears.
28
Siemens Building Technologies
Fire Safety & Security Products 05.2009
CCIC1410 Installation Wizard
Fig. 5 Network Settings page
4. Enter the information for the LAN setting.
5. Click Next and follow the pages of the Installation Wizard.
DHCP or fixed IP:
zDHCP:
Checking the Get IP by DHCP Server automatically checkbox will force the
device to renew its IP address whenever it reboots, and the related network
configuration is provided by the DHCP server.
zFixed IP:
If you want the device to use a fixed IP, please uncheck the Get IP by DHCP Server automatically checkbox and assign a valid IP address, subnet mask,
default gateway and DNS server for the device.
29
Siemens Building Technologies
Fire Safety & Security Products 05.2009
Loading...
+ 67 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.