Contents
System Overview 3
Getting Started 8
2D Mode and M-mode 12
Color and Spectral Doppler 24
Measurements and Calculations 38
Text, Arrows and Pictograms 48
Data and Image Management 54
2

System Overview
Control Panel
1. Power ON / OFF
(QuikStart Standby Mode)
2. Patient Study Controls
3. User-defined Keys
4. Soft Key Rotary Controls
5. Alphanumeric Keyboard
6. Text, Arrows and Pictograms
7. Major Modes
8. Angle, Steer, Select
9. TGO Image Optimization
10. DCG Controls
11. Depth, Zoom, Focus
12. UD (User-defined Key), Dual
13. Print, Store and Clip
14. Freeze
15. Home Base Controls
1
2
3
4
5
6
8 9
10
11
12
13
14
15
7
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
3

System Overview
1. Left Set
2. Right Set
3. Update / View
4. Escape
5. Caliper
6. Trackball (CINE review)
7. Wrist Support
Home Base Area
1
3
6
7
2
4
5
4

Connecting Transducer
In the unlocked position, insert the transducer
into the port located on the front of the system.
Turn the lock clockwise until it locks into place.
System Overview
6

Wheel Locks
Unlocked (wheels can swivel and roll). Locked (wheels cannot swivel and roll).
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
System
Overview
7

Getting Started
Patient Registration
New Patient
1. Press
New Patient
2. Enter patient information.
3. Select the Transducer and Exam type and
select OK.
Transducer can also be selected
from the Touch Screen (if 3 or more
transducers are connected to the
system) after patient registration or
by selecting Exam on the Control
Panel.
TIP
8

1. Press
2. Use the keyboard to edit patient information.
3. Select
OK
to save.
Patient Registration – Worklist
1. Press
New Patient
2. Enter patient information to search.
3. Select Worklist at the upper left side of
the form
- Select US (Ultrasound) Search
- Select the study and press
Select
- Select
OK
to begin the study.
System must be connected to a HIS / RIS
server to access patient worklist.
Edit Study
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
9

Transducer / Study
Control Panel and Touch Screen
1. Select
Exam
or
2. Select a transducer from the upper left menu
on the image screen.
3. To change transducers during an exam,
press Exam or the user-defined key assigned
to the transducer.
4. Select the transducer on the Touch Screen.
Selection of transducers via the
Touch Screen is available once three
or more transducers are connected.
TIP
Getting Started
10

Store, Print, Review and End Exam
1. Press
to acquire and save the clip.
2. Press
Freeze
to freeze the clip / image frame.
3. If desired, roll trackball for frame-by-frame
CINE review.
- Press
to save a static image.
- Press
to save and print.
4. Press
, then
- Press
Select
to view 1x1 format
- Rotate
Select
to move between images.
5. Press
END
on the keyboard to end the study.
Starting a new patient also ends
a current exam.
A compatible printer must be connected
and assigned to the print function in the
Presets menu before the print function
becomes active. Print Store 1 and 2 are
customized in the Presets menu.
TIP
Review
Select
System
Overview
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Getting
Started
11

2D Control Panel
Control Panel Controls Function
2D
Brightness Mode
Press to enter / exit 2D mode.
Rotate to adjust overall 2D gain / brightness.
TGO
(TGO™ Tissue Grayscale
Optimization Technology)
One-button image optimization
Press to optimize the overall image displayed.
Press twice to deactivate.
Note: Available on live image only.
DGC
Manually adjusts gain / brightness at depth
Default all slide controls in the center.
Note: Available on live image only.
Focus
Adjusts the focal zone
Rotate to move up / down and press to activate multiple focal zones.
Note: Only available with certain transducers.
2D Mode and M-mode
12

Depth / Zoom
Adjusts the scanning depth and magnifies the image
Rotate clockwise / counter-clockwise to increase /
decrease depth.
Press to activate zoom.
Rotate to change region of interest (ROI) size and press to activate.
Press again to exit zoom.
Note: Zoom available in live or frozen images.
HD Zoom
Displays a high density zoom
Press to activate.
Rotate the Depth / Zoom to increase / decrease ROI.
Press Depth / Zoom or HD Zoom to activate.
Dual
Displays two separately acquired images side-by-side
Press Dual to activate and toggle between images.
Press the 2D key to exit.
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
13

2D Touch Screen
Touch Screen Controls Function
TGO Gain*
Controls the TGO gain offset
Select to adjust up / down.
Note: TGO must be active to adjust.
Trapezoid
Displays linear or trapezoid image format
Select to activate / deactivate.
Note: Available on live image only. Available on linear transducers
only. Defaults to SieClear 2 upon activation.
4B
Displays four separately acquired images
Select to activate and add each image.
Note: Available on live image only in 2D and Color Doppler.
Image Presets*
Image optimization presets
Select to view available image presets.
Note: Available on live image only.
Customizable in a user-defined exam only.
THI (Tissue Harmonic
Imaging)
Increases contrast and lateral resolution. Reduces noise and clutter.
Select to activate / deactivate.
Note: Available on live image only.
2D Mode and M-mode
14

SieClear (SieClear™
Multi-view Spatial
Compounding)* and
AdvSieClear (Advanced
SieClear™ Spatial
Compounding)*
Enhances contrast resolution and boundary detection
Increase for more compounding.
Decrease for less compounding.
Note: Available on live image only. Settings are transducer and mode
dependent.
Edge*
Sharpens the contours of a structure
Increase for more sharpness.
Decrease for less sharpness.
To deactivate, select zero.
Note: Available on live image only.
RS (Resolution / Speed)*
Balances line density (spatial resolution) and frame rate
Increase to improve image detail.
Decrease to improve frame rate.
Note: Available on live image only.
DTCE
(Dynamic TCE™ Tissue
Contrast Enhancement
Technology)*
Reduces speckle and enhances tissue contrast
Settings are Low, Medium and High.
Note: Available on live or frozen images.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
2D Mode
and M-mode
15

Touch Screen Controls Function
Split
Activates two simultaneous images in dual format
Select to activate / deactivate.
DTO
(DTO™ Dynamic Tissue
Optimization Technology)
Activates level of gain compensations. Reduces bright whites.
Increase to reduce whites.
ClarifyVE
(Clarify™ Vascular
Enhancement (VE)
Technology)
Decreases artifacts, increases contrast resolution and boundary
detection in structures with flow
Press to activate / deactivate.
Note: Available on live imaging only.
ClarifyVE Levels*
Adjusts levels of sensitivity when using ClarifyVE
Rotate clockwise to increase sensitivity.
Rotate counterclockwise to decrease sensitivity.
Select a higher level to increase.
Select a lower level to decrease.
Note: Available on live imaging only.
2D Mode and M-mode
2D Touch Screen
16

Persist (Persistence)*
Frame averaging – determines the number of frames combined into
the final image
Increase for more frame averaging.
Decrease to demonstrate motion.
To deactivate, select 0.
Note: Available only on live image when SieClear is set to Off.
U/D Flip (Up / Down flip)
R/L Flip (Right / Left flip)
Adjusts orientation on image screen
Select to switch between orientations [up(U) or down(D) and right(R)
or left(L)].
Note: Available on live or frozen image.
Clip Capture >>
Selects type of clip capture
Chronology: Prospective, Retrospective.
Acquisition Rate: Normal, High.
Trigger Type: Time Capture, Beat Capture, Rwave Capture.
Note: Available on live image only.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
2D Mode
and M-mode
17

2D Soft Keys
Soft Key Controls Function
P (Transmit Power)
Adjusts acoustic energy delivered to the patient
Rotate clockwise to increase power.
Rotate counterclockwise to decrease power.
Note: Available on live image only. Changes Mechanical (MI) and
Thermal (TIS, TIB) Indices.
DR (Dynamic Range)*
Adjusts number of gray shades displayed
Rotate clockwise for a softer / grayer image.
Rotate counterclockwise to increase contrast.
Note: Available on live or frozen images.
MultiHertz
(MultiHertz™ Multiple
Frequency Imaging)
Balances between resolution and penetration
Use higher frequency to increase resolution.
Use lower frequency to increase penetration.
Note: Available on live image only.
2D Mode and M-mode
18

Map
Processing curves that assign echo amplitudes to gray shades
Maps A – I are from low to high contrast.
Maps 1– 3 are customizable maps (Modify Map).
Note: Available on live or frozen images.
Tint
Colorizes the grayscale image
Press and rotate for tints from 0 –15.
Note: Available on live or frozen images.
Rotate
Adjusts image orientation in 90 degree increments
Rotate to adjust.
Note: Available on live image only.
Configurable for the touch screen controls and/or soft rotary keys.*
System
Overview
Getting
Started
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
2D Mode
and M-mode
19

M-mode Control Panel
Control Panel Controls Function
M (M-mode)
Enters / exits M-mode and adjusts overall M-mode gain
Press to activate / deactivate.
Roll the trackball to position the M-mode cursor.
Rotate to adjust overall M-mode gain.
Note: Available on live image only.
Update / View
Alternates between 2D / M-mode formats on the Touch Screen
Press to move between modes.
Note: Available on live image only.
Color M-mode
Enters / exits color M-mode
With Color Doppler activated, press M (M-mode).
Place cursor and Press M.
Press M to exit.
Note: Only available with cardiac transducers.
2D Mode and M-mode
20

M-mode Touch Screen
Touch Screen Controls Function
Full M
Changes the display format to full M-Mode
Press to activate / deactivate.
Note: Available on live or frozen image.
Sweep Speed*
Adjusts the scrolling speed of the M-mode sweep
Increase to display less cardiac cycles.
Decrease to display more cardiac cycles.
Note: Available on live or frozen image.
Edge*
Sharpens the contours of a structure in the M-mode sweep
Increase for more sharpness.
Decrease for less sharpness.
To deactivate, select 0.
Note: Available on live image only.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
2D Mode
and M-mode
21

M-mode Soft Keys
Soft Key Controls Function
MultiHertz (frequency)
Adjusts Frequency for 2D image and M-mode strip
Rotate clockwise to increase resolution.
Rotate counterclockwise to increase penetration.
Note: Available on live image only.
Maps
Processing curves that assign echo amplitudes to gray shades in the
M-mode sweep
Map choice is displayed from low to high contrast.
Note: Available on live or frozen image.
Tint
Colorizes the M-mode sweep
Press and rotate for tints from 0 –15.
Note: Available on live or frozen image.
DR (Dynamic Range)*
Adjusts number of gray shades displayed in the M-mode sweep
Rotate clockwise for a softer / grayer sweep.
Rotate counterclockwise for increased contrast.
Note: Available on live or frozen image.
2D Mode and M-mode
Configurable for the touch screen controls and/or soft rotary keys.*
22

Color Doppler Control Panel
Control Panel Controls Function
C (Color Doppler)
Enters / exits color Doppler or adjusts overall color Doppler gain
Press to activate / deactivate color Doppler mode.
Rotate to increase / decrease color Doppler gain.
Note: Available on live image only.
Power (Power Doppler)
Applies colors based on flow amplitude
Select Power to activate / deactivate.
Rotate to increase / decrease power Doppler gain.
Note: Available on live image only.
Color Box Size / Position
Adjusts the color ROI
Increase frame rate by decreasing the color ROI width or depth.
Press Set to alternate between Size / Position.
Roll the trackball to resize or reposition color ROI.
Note: Available on live image only.
Steer
Steers the Color ROI
Toggle the Steer key left / right to steer.
Note: Steering Angle is transducer dependent. Available only on
linear transducers.
Color and Spectral Doppler
24

Color Doppler Touch Screen
Touch Screen Controls Function
Flow*
Flow state optimization presets
Choices are Low, Medium, High.
Select desired preset to optimize flow state.
Note: Available on live image only.
Invert
Reverses the colors depicting forward and reverses flow in the color
ROI and the color bar
Select to activate / deactivate.
Note: Available on live or frozen image.
RS (Resolution / Speed)*
Balances line density (spatial resolution) and frame rate
Increase for image detail.
Decrease to increase frame rate.
Note: Available on live image only.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
25

Touch Screen Controls Function
Smooth*
Adjusts spatial averaging (smoothing) for color flow
Increase for flow sensitivity.
Decrease for color spatial resolution.
Note: Available on live image only.
Persistence*
Adjusts the time that the color flow data remains in the ROI before
being replaced by another color
Increase for greater vessel color fill.
Decrease to increase temporal resolution.
Note: Available on live image only.
Filter*
Adjusts the color wall filter
Increase to reduce motion artifacts.
Decrease to increase sensitivity to low flow states.
Note: Available on live image only.
Color and Spectral Doppler
Color Doppler Touch Screen
26

Priority*
Prioritizes the display of grayscale or color flow data
Increase for greater vessel color fill.
Decrease to prioritize grayscale and less vessel color fill.
Note: Available on live image only.
Display
Turns color display off image when in Color Doppler
Select to activate / deactivate.
Note: Color ROI remains on image.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
27

Soft Key Controls Function
MultiHertz (frequency)
Adjusts the color Doppler frequency independent of the 2D frequency
Rotate to increase / decrease.
Note: Available on live image only.
Maps
Selects a processing curve that assigns the velocity / velocity variance
(for Color) or flow amplitudes (for Power) to a range of colors
Maps choices are A – I.
Note: Available on live or frozen image.
P (Transmit Power)
Acoustic energy delivered to the patient in color Doppler mode
Increase / decrease to adjust the transmit power.
Note: Available on live image only. Changes Mechanical and Thermal
Indices displayed.
Color and Spectral Doppler
Color Doppler Soft Keys
28

Scale
Adjusts the pulse repetition frequency (PRF)
Increase / decrease to adjust the PRF.
Note: Available on live image only.
Baseline
Adjusts the range of flow velocities displayed above and below
the baseline
Move up / down to adjust the baseline of the active mode.
Note: Available on live image only.
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
29

Color and Spectral Doppler
Spectral Doppler Control Panel
Control Panel Controls Function
D (pulsed wave) Doppler
and CW (continuous
wave) Doppler
Enters / exits spectral Doppler or adjusts overall spectral Doppler gain
Press to activate / deactivate.
Roll trackball to position Doppler gate.
Press D or CW to activate the strip.
Rotate to adjust overall spectral Doppler gain.
Note: Available on live image only.
TGO (TGO Technology)
One button optimization of spectral Doppler gain, baseline, and scale
With Doppler spectrum active, press to activate.
Press twice to exit TGO.
Note: Available on live image only.
Update / View
Alternates between the Doppler spectrum and the 2D image
Press to alternate between Doppler / 2D.
Note: Available on live image only.
30

Steer
Adjusts the PW Doppler angle
Toggle left / right to reverse the steering angle.
Note: Available on live image only. Available only on linear
transducers.
Angle
Adjusts angle correction
Press to cycle through 60 / 0 / 60° angle selections.
Rotate to adjust values in 1° increments.
Note: Available on live or frozen image.
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
31

Color and Spectral Doppler
Spectral Doppler Touch Screen
Touch Screen Controls Function
Triplex
Enters / exits Duplex or Triplex mode
Select to activate / deactivate Duplex / Triplex.
Note: Available on live image only.
Gate*
Adjusts sample volume size
Increase / decrease to adjust size.
Note: Available on live image only.
Invert
Reverses the Doppler spectrum (negative values display above the
baseline)
Select to activate / deactivate.
Note: Available on live or frozen image.
Sweep*
Adjusts the scrolling speed of the Doppler spectrum
Increase to display less cardiac cycles.
Decrease to display more cardiac cycles.
Note: Available on live or frozen image.
32

Mute
Mutes the Doppler audio
Select to activate / deactivate.
Note: Available on live image only.
Full D
Displays Full Screen Doppler
Select to activate / deactivate.
Note: Available on live or frozen image.
Filter*
Adjusts the wall filter
Rotate to adjust rejection of low frequency signals.
Note: Available on live image only.
Sensitivity*
Adjusts the sensitivity of the Trace tool when in Auto Stats
Increase for higher sensitivity. Choices are 1–5.
Note: Available on live image only.
Update Rate*
Defines the interval for refreshing the 2D-mode image
Select Off, 1 sec, 2 sec, 4, sec, 8 sec or EOS (End Of Sweep).
Note: Available on live image only.
Configurable for the soft key rotary controls and/or touch screen user interface.*
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
33

Color and Spectral Doppler
Spectral Doppler Touch Screen
Touch Screen Controls Function
Auto Stats*
Automatic trace and display of PW Doppler measurements
Select to activate / deactivate.
Select settings for data above, below or on both sides of the baseline.
Note: Available on live or frozen image.
DTI (DTI™ Doppler Tissue
Imaging Capability)
Activates the Doppler Tissue imaging feature for cardiac exams
Press to activate / deactivate.
Note: Available on live image only.
T/F Res*
(Time / Frequency
resolution)
Adjusts the balance between the temporal and frequency resolution
of the Doppler spectrum
Increase to increase temporal resolution.
Decrease to increase frequency resolution.
Note: Available on live image only.
Configurable for the soft key rotary controls and/or touch screen user interface.*
34

Color and Spectral Doppler
Spectral Doppler Soft Keys
Soft Key Controls Function
Baseline
Adjusts the range of velocities displayed
Increase / decrease to adjust the baseline.
Note: Available on live or frozen image.
Scale
Adjusts the pulse repetition frequency (PRF)
Increase / decrease to adjust the PRF.
Note: Available on live image only.
DR (Dynamic Range)*
Adjusts number of gray shades displayed
Rotate clockwise for a softer / grayer spectrum.
Rotate counterclockwise for a greater contrast spectrum.
Note: Available on live or frozen image.
MultiHertz (frequency)
Adjusts spectral Doppler frequency independent of the 2D or color
frequency
Increase / decrease to adjust.
Note: Available on live image only.
36

Map
Selects a processing curve that assigns echo amplitudes to gray
shades in the Doppler spectrum
Select desired Map from A – H.
Note: Available on live or frozen image.
Tint
Colorizes the Doppler spectrum
Select desired Tint from 0 – 11.
Note: Available on live or frozen image.
Configurable for the touch screen controls and/or soft rotary keys.*
System
Overview
Getting
Started
2D Mode
and M-mode
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
Color and
Spectral Doppler
37

Measurements and Calculations
Unlabeled Measurements
Perform Measurement
1. Press
2. Select the desired measurement type and
Press Caliper.
3. Roll the trackball to position the first caliper.
4. Press
to anchor
Measurements can be performed on
frozen, CINE and stored images
TIP
5. Roll the trackball to position the second
caliper.
6. Press
to complete the measurement.
Unlabeled measurements do not enter
into the exam report.
38

Labeled Measurements
1. Press
2. Roll the Trackball to select the desired Exam
type and measurement label and press Set.
3. Roll the trackball to position the first caliper.
4. Press
to anchor
5. Roll the trackball to position the second
caliper.
6. Press
to complete and send the labeled
value(s) to the patient report.
The measurement label can be
selected before or after calipers
are placed.
TIP
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
39

Edit Measurements (Labeled and Unlabeled)
Edit Completed Measurement
1. Press
to activate calipers and cycle
between active calipers.
2. Press
6HOHFW1H[W
on the Touch Screen to cycle
between calipers sets.
3. Press
'HOHWH
on the Touch Screen or press the
Select
key to remove active measurement.
4. Push
'HOHWH$OO
on the Touch Screen to delete
all measurements.
5. Rotate
Undo / Redo
or the Select key to edit a
trace measurement.
Measurements and Calculations
40

Reposition Measurement Results
1. Press
2. Rotate
0'$3RVLWLRQ
and
0'$6L]H
to cycle through
the available size and positions.
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Text, Arrows
and Pictograms
Data and Image
Management
Measurements
and Calculations
41

Measurements and Calculations
Report
Review the Report
1. Press
Report
or
5HSRUW
on the Image screen to
enter / exit report page.
2. Select a report heading for Data or Description.
3. Press Next to review additional measurements.
4. Select Send Report to send to connected
external printer.
5. Press
to store report as a thumbnail.
6. Select Return to exit the Report.
7. To edit the report, roll the trackball to
the desired measurement and edit.
8. Press Summary to generate a revised
Summary.
Only labeled measurements appear on
the report. An * appears for any edited
measurement.
42

2
2
3
4
6
3
6
Touch Screen Image Screen
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Text, Arrows
and Pictograms
Data and Image
Management
Measurements
and Calculations
43

Measurements and Calculations
Review the Summary
1. Press
to activate the measurement package.
2. Press
Report
to enter / exit report page.
3. Select
6XPPDU\
on the Touch or Imaging Screen.
4. Select
Export to USB
to send to USB as a pdf file.
5. Select
Print
to print to a connected printer.
6. Select
Exit
to exit the Report.
Summary
44

3
6
4 5
Touch Screen Image Screen
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Text, Arrows
and Pictograms
Data and Image
Management
Measurements
and Calculations
45

Measurements and Calculations
Import Images into the Summary
1. Press
to activate the measurement package.
2. Press
Report
to enter / exit report page.
3. Select
6XPPDU\
on the Touch or Imaging Screen.
4. Select the Display format from the Summary
Page.
5. Roll the trackball to the thumbnail image and
press the
Set
key to highlight.
Up to 20 images can be stored to the
Summary.
TIP
6. Roll the trackball to the desired image location
in the Image section and press the
Set
Key
to drop the image in report.
7. To Delete the image, move the cursor over
the image and press
Delete Image
Summary
46

Text Icons
Control Function
Activates / deactivates text cursor and text Touch Screen menu.
6HW+RPH
3RVLWLRQ
Sets default position for text cursor.
+RPH3RVLWLRQ
Positions the cursor at the home location.
+LGH7H[W
Temporarily hides text.
&OHDU6FUHHQ
Deletes all text, pictograms or arrows.
'HOHWH/LQH
Deletes one line of text at the cursor.
Text, Arrows and Pictograms
48

'HOHWH:RUG
Deletes the last word.
295
Inserts or overwrites text when text cursor is active.
Displays the next or previous page, when available.
Caps Lock
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
49

Text, Arrows and Pictograms
1. Press the Arrow or Text key on the keyboard.
2. Select the Arrow tab on the Touch Screen.
3. Roll the trackball to position.
4. Turn Rotate or turn Select to change
arrow direction.
5. Rotate Arrow Size to adjust arrow size.
6. Press Set to anchor.
7. Press New or Select to add another arrow.
8. Press Delete to delete the last arrow.
9. Press Delete All to delete all arrows
10. Press Select Arrow or Update to cycle
through multiple arrows.
11. Press Exit to exit Arrow function.
Unlimited arrows can be added.
TIP
Arrows
50

from the keyboard.
2. Select the desired pictogram from the Touch
Screen.
3. Roll the trackball to position the transducer
icon.
4. Press
Rotate
on the Touch Screen or rotate
the
Select
key to rotate the transducer icon.
5. Press
to anchor.
6. Press
Delete
on the Touch Screen or
&OHDU6FUHHQ
on the keyboard to delete the
Pictogram.
Pictograms are customized in the
Presets Menu by selecting Presets /
Pictogram List.
Pressing Clear Screen also deletes any
text or measurements on the image.
TIP
TIP
Pictograms
Text, Arrows and Pictograms
52

Review Images
Data and Image Management
Review Images on Current Study
1. Press
and press
Select
and
double-click a thumbnail.
2. Select
or press
)RUPDW
;
to change the
display format.
3. Rotate the
Select
key to view more images.
4. Press
or
2D
to exit.
Review Images from a Closed Study
1. Select
2. Select a patient and press the key twice
to open.
3. Select
or press
)RUPDW
;
to change the
display format.
4. Rotate the
Select
key
to view more
images.
5. Press
or
2D
to exit.
54

Delete Images from a Current Study
or in Review
1. Press
Select
to activate cursor.
2. Select an image on the thumbnail panel to
highlight.
3. Select
located below thumbnail panel
and answer prompt “Yes” to Delete.
4. Or, press
5. Press
Select
to activate cursor.
6. Highlight an image from the Imaging Screen
7. Press
'HOHWH
on the Touch Screen or
'HOHWH
from the imaging screen.
8. Answer the prompt “Yes” to Delete.
1. Select
2. Select exam from Local Disk.
3. Select
5HRSHQ
located below the list of exams
on the right to restart exam.
4. Patient data screen will populate, press OK
to open study.
Delete Images Restart an Exam
Images, clips and volumes can be
added to a closed study within 24
hours.
TIP
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
55

1. Select
2. Select the exam from Local Disk.
3. Roll the trackball, highlight an image or clip
and press the
key. Repeat for all desired
images.
4. Press
7HDFKLQJ)LOH
on the Touch Screen.
5. Under Add Teaching File, name the file and
press Close.
6. The teaching file is displayed in the Patient
Browser.
Teaching File
Images and Clips stored in teaching
file removes all patient data.
TIP
Data and Image Management
7. To add images from multiple studies, follow
steps 1–
4, then select the desired teaching
file.
8. Press
$SSHQG
to add the additional images.
56

Export Study to DICOM Network
1. Select the patient name in the Patient
Browser.
2. Under Network, select the desired
Destination.
3. Select Send.
Export Study to CD-R / DVD in DICOM
1. Insert CD-R / DVD.
2. Select the patient name in the Patient
Browser.
3. Select Local Disk from the Drop Down under
Export / Import.
4. Select CD / DVD and select DICOM as the export
format and select Export.
Export Studies
Hold CTRL to select more than one
patient name. A showcase DICOM
viewer will be burned onto the CD-R or
DVD with the patient data if selected
in the Presets Menu (Presets / Archive /
CD / DVD.
Images automatically send to PACs
if the system is configured to send
during the exam or at the end of
the exam.
TIPTIP
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
57

Export Study to USB in PC Format (TIFF or AVI)
1. Insert USB.
2. Select the patient name in the Patient
Browser.
3. Select USB and the Tiff / AVI export format.
4. Select Export.
Import Study from CD-R / DVD to Local Database
1. Insert CD-R / DVD.
2. Select CD / DVD from Export / Import in the
Patient Browser.
3. Select patient name on the CD / DVD.
4. Select Import.
Import / Export Studies
Data and Image Management
58

Import Study from USB to Local Database
1. Insert USB.
2. Select USB from Export / Import in the Patient
Browser.
3. Select patient name on the USB.
4. Select Import.
System
Overview
Getting
Started
2D Mode
and M-mode
Color and
Spectral Doppler
Measurements
and Calculations
Text, Arrows
and Pictograms
Data and Image
Management
59

Legal Manufacturer
Siemens Medical Solutions USA, Inc.
Ultrasound
685 East Middlefield Road
Mountain View, CA 94043
USA
Phone: +1-888-826-9702
siemens.com/ultrasound
Siemens Healthcare Headquarters
Siemens Healthcare GmbH
Henkestr. 127
91052 Erlangen
Germany
Phone: +49 9131 84-0
siemens.com/healthcare
ACUSON NX3, Advanced SieClear, Clarify VE, DTI, DTO, Dynamic
TCE, MultiHertz, SieClear and TGO are trademarks of Siemens
Medical Solutions USA, Inc.
The products / features mentioned in this document may not be
commercially available in all countries. Due to regulatory reasons
their future availability cannot be guaranteed. Please contact
your local Siemens organization for further details.
Images used in this guide are for educational purposes only.
They have been modified or compressed and may not reflect
the actual image quality of the system.
siemens.com/healthcare
Order No. A91US-400-1C-4A00 | Printed in Germany | CC 3494 0416X. | © Siemens Medical Solutions USA, Inc., 2016