1 - Weather shield side, male (bottom)
1 - Weather shield side, female (top)
4 - UV resistant cable ties
Equipment damage, or loss
Actuator Weather Shield
Product Description
The 599 Series Powermite and Zone Valve Actuator
weather shield provides additional protection against
the elements for actuators in outdoor installations.
The cover is easy to install, with all necessary
hardware included in the assembly kit.
NOTES:
• This unit is approved for outdoor installation
only when a weatherproof conduit connec tor
is used.
• The weather shield provides NEMA 3R
protection against rain, sleet and damage
from external ice formation when installed in
the orientation shown in Figure 3.
Contents
Document No. 129-431
October 5, 2009
Installation
1. Punch a hole through weather shield at the
preferred conduit location.
2. Install male side (bottom) of weather shield over
valve. See Figure 1.
Figure 1.
Product Number
599-10077
Caution Notation
of data may occur if you do
not follow procedures as
Required Tool
Conduit knockout punch
Expected Installation Time
15 minutes
Item Number 129-431, Rev. 010
Page 1 of 2
3. Install actuator on to valve. See Figure 1.
NOTE: See Figure 3 for mounting restrictions.
4. Connect conduit to weather shield using a
weatherproof conduit connection.
5. Wire actuator according to installation
instructions.
6. Place female side (top) of weather shield over
bottom of installed weather shield (male side).
7. Align holes in the weather shield side flanges and
secure with four cable ties. See Figure 2.
Figure 2. Installed Weather Shield.
Over-tightening cable ties can damage
the assembly.
The installation is now complete.
![](/html/de/dea9/dea92b9ff7ae34c2ef0c171453df9e1bde8a9d9fe94a6dc36058dcaa9e8a7a76/bg2.png)
Document Number 129-431
Installation Instructions
October 5, 2009
Mounting
The actuator and Weather Shield must be mounted
vertically to ensure NEMA 3R rating.
Figure 3. Acceptable Mounting Position.
Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models
as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners.
©2009 Siemens Industry, Inc.
Building Technologies Division
1000 Deerfield Parkway
Buffalo Grove, IL 60089
Your feedback is important to us. If you have
comments about this document, please send them
to sbt_technical.editor.us.sbt@siemens.com
Document No. 129-396
Printed in the USA
Page 2 of 2