Operating instructions
Contents
Intended use................................................................................................. 2
Improper use................................................................................................ 2
Safety notes.................................................................................................. 2
GENIUS
Description of device and functions................................................................ 3
Switching the acoustic signal on and off........................................................ 4
Locking and unlocking the door.................................................................... 5
Operating the system with optional external devices.................................... 6
Programming................................................................................................ 7
Infra-red access keys .................................................................................. 8
Programming in the infra-red master key..................................................... 9
Programming in infra-red access keys.......................................................... 9
Deleting infra-red access keys....................................................................... 9
Replacing the batteries................................................................................... 10
Disposing of batteries .................................................................................. 11
Malfunctions................................................................................................. 11
Technical specifications.................................................................................. 12
Liability......................................................................................................... 12
Last update: 01.08.2013
1
GENIUS
Operating instructions
Intended use
• The GENIUS door lock is a special lock for locking and unlocking doors automatically.
• It is suitable for installation in timber, aluminium, steel and PVC entry doors for residential and public buildings.
• All assembly and electrical installation work must be carried out according to our assembly and installation instruc-
tions. Wiring the unit incorrectly can irreparably damage its electronic components.
• The GENIUS door lock must be operated with a free-running cylinder compliant with the German standard DIN
18252. Alternatively a thumbturn cylinder can be used, but it should be noted that this will result in a loss of strength
at the locking points.
• The GENIUS door lock can be connected to an external access control system (e.g. wireless, transponder or fingerprint scanner system) via a voltage-free contact (switching time: min. 1 second).
• Use the GENIUS door lock only when it is in a technically sound condition. Do not modify the unit's components in
any way.
• Use the GENIUS door lock only with genuine KFV accessories.
Improper use
• The GENIUS door lock must not be used with a cylinder with a fixed catch, as this will cause the main lock to jam
when the key is removed.
• The GENIUS door lock must not be installed in moisture-prone areas or areas with a corrosive atmosphere (e.g. electroplating shops).
• The length of the cable between the power supply and the GENIUS door lock must not exceed 13 m.
Safety notes
• Work on an 230 V AC mains power supply may only be performed by a qualified electrician.
• All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regu-
lations (e.g. VDE 0100) and any relevant country-specific requirements.
• All-pole safety isolation should be used when fitting the power lead on-site.
• Some external access control systems available on the market transmit a brief "open" signal when the operating vol-
tage is switched on. This can mean that the GENIUS door lock will open the door following a power cut. If in doubt,
please contact the system manufacturer.
Warning
Where power supply cables are routed parallel to data cables (IDSN, DSL etc), interference can occur, eg: with
the data transfer speed.
2 Last update: 01.08.2013
Operating instructions
Description of device and functions
Day/night mode
The desired mode (day or night) can be selected using the toggle switch on the GENIUS door lock.
GENIUS
Fig. 1: Toggle switch for selecting day/night mode
Day mode
Switch position up
• The door is held shut by the latch.
• To allow the door to open, the latch retracts into the lock.
• This mode is recommended for doors with heavy traffic.
Night mode
Switch position down.
• The door is locked automatically after each opening.
• When the door is opened it is also unlocked automatically.
• The latch retracts into the lock for approximately 7 seconds. If the door is not opened during this time, it is locked
again after these 7 seconds have elapsed.
Note: If the door needs to be locked (e.g. at night, or when the building is empty), night mode must be selected.
Last update: 01.08.2013
3