Siegenia AS 3600,AS 3600 T4,AS 3600 TA,AS 3600 T3,AS 3600 with A-opener Operating Instructions Manual

KFV
DEUTSCH
ENGLISH FRANÇAIS ESPAÑOL ITALIANO NEDERLANDS ČESKÝ POLSKI РУССКИЙ
AS 3600 AS 3600 TA AS 3600 T4 AS 3600 T3 AS 3600 with A-opener
Multi-point lock
Window systems
Door systems
Comfort systems
OPERATING INSTRUCTIONS
Operating instructions AS 3600/AS 3600 TA/AS 3600 T4/ AS 3600 T3/ AS 3600 with A-opener
Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Validity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Target group of this documentation . . . . . . . . .4
1.3 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3.1 Installation location . . . . . . . . . . . . . . . . . . . . .4
1.3.2 Locking part and hardware . . . . . . . . . . . . . . .4
1.4 Improper use . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.5 Maintenance and service notes. . . . . . . . . . . . 4
1.6 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.7 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.8 Visual indicators . . . . . . . . . . . . . . . . . . . . . . . 4
1.8.1 Instructions and symbols . . . . . . . . . . . . . . . . . 4
1.9 Other types of indicators . . . . . . . . . . . . . . . . . 4
1.10 Causes of damage . . . . . . . . . . . . . . . . . . . . .5
2. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Misuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Definition of terms . . . . . . . . . . . . . . . . . . . . . .7
3.1.1 Multi-point lock and door leaf . . . . . . . . . . . . .7
3.1.2 Frame parts and door frame . . . . . . . . . . . . . .8
3.2 Features of the delivery versions . . . . . . . . . . 9
3.2.1 AS 3600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2.2 AS 3600 T3 safety lock . . . . . . . . . . . . . . . . 9
3.2.3 AS 3600 T4 safety lock . . . . . . . . . . . . . . . . 9
3.2.4 AS 3600 TA daytime function . . . . . . . . . . . 10
3.2.5 AS 3600 TA/T3
daytime function/ safety lock . . . . . . . . . . . 10
3.2.6 AS 3600 A-opener . . . . . . . . . . . . . . . . . . . 10
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 AS 3600 Basic functions . . . . . . . . . . . . . . . 11
4.2 AS 3600 TA ......................
Activating/deactivating the
daytime function . . . . . . . . . . . . . . . . . . . . . 12
4.3 AS 3600 T4 Activating/deactivating
the safety lock . . . . . . . . . . . . . . . . . . . . . . . 15
4.4 AS 3600 T3 Activating/deactivating
the safety lock . . . . . . . . . . . . . . . . . . . . . . . 16
4.5 AS 3600 Operating the A-opener. . . . . . . . 17
4.5.1 A-opener: . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5. Cleaning and maintenance . . . . . . . . . . . . . 18
306.2017
KFV
Operating instructions AS 3600/AS 3600 TA/AS 3600 T4/ AS 3600 T3/ AS 3600 with A-opener
1. Introduction
Please read these operating instructions carefully before you begin the assembly work. Follow the instructions in Chapter2 "Safety", in order to prevent personal injury or disturbance.
1.1 Validity
These instructions describe the operation of the AS 3600, AS 3600 TA and AS 3600 T4 automatic multi-point locking systems. They are applicable until they are revoked.
1.2 Target group of this documentation
This documentation is intended for use by end users. In order to guarantee the safe use of the AS 3600, AS 3600 TA and AS 3600 T4 automatic multi-point locks and prevent malfunction or damage, please read these operating instructions carefully and completely and observe the instructions specified in the chapter "Safety" in particular.
1.3 Intended use
1.3.1 Installation location
• The multi-point lock is suitable for installation in single­sash and double-sash doors in permanent buildings.
• The multi-point lock may only be installed in doors that have been fitted in a technically sound manner.
• The door design must permit use of the multi-point lock.
1.3.2 Locking part and hardware
• Repair of the multi-point lock is not permissible. If the multi­point lock is damaged, it must be replaced by KFV or repaired by a service agent authorised by KFV.
• Only KFV frame parts with Q adjustment may be used.
• The locking elements must always engage freely in the lock striker of the frame parts.
1.4 Improper use
• Do not use for escape doors.
• The multi-point lock is not designed to accommodate changes to its shape or seal which arise as a result of differences in temperature or changes to the building.
• The multi-point lock must not be used in doors for wet rooms or rooms in which the air contains aggressive or corrosive components.
• Foreign objects and/or materials which impede or prevent proper use must not be placed within the opening range, the locking system or the striker plates.
• The multi-point lock must not be interfered with and/or modified.
• Locking elements must not be misused to hold the door open.
• Movable or adjustable locking pieces (e.g. deadbolt, latch) must not be painted over.
1.5 Maintenance and service notes
• A regular annual maintenance should be carried out to check that all movable components are functioning correctly.
• The falling bolts of the auxiliary boxes must be lubricated with grease once a year. Only use oil-based PTFE spray H1 for this purpose. Do not use lubricants containing solvents or resins. All further components of the multi-point lock have already been treated with long-term lubrication and are consequently maintenance-free.
• Never use cleaning agents that are aggressive or contain solvents, as these may damage the surface of the components.
1.6 Transport
• Always transport the multi-point lock in a vertical position, whether uninstalled or installed in the door leaf.
• Use the transit supports included in the delivery for the transport of a pre-assembled door. This prevents the unlocking of falling bolts and hook bolts.
• Also block set the door leaf in the frame.
• Do not place the multi-point lock heavily on the ground when it is unpackaged, as this can damage the lock.
• Do not carry the door by the lever handle or hardware when transporting it.
• Opening/closing/locking: It must be possible to open and close the door easily. A protruding latch and /or deadbolt must not impede the opening and closing of the door.
1.7 Dimensions
All measurements are given in mm.
1.8 Visual indicators
1.8.1 Instructions and symbols
This symbol indicates special features and designates facts that require increased attention.
1.9 Other types of indicators
Below is a list of symbols used in these assembly instructions and their meanings:
• Items of text following this marker are found in lists.
► Items of text with this marking in front of them are
instructions that must be followed in the specified order.
" " Items of text in quotation marks are cross-references to other chapters or sections.
Introduction
4 06.2017
KFV
Operating instructions AS 3600/AS 3600 TA/AS 3600 T4/ AS 3600 T3/ AS 3600 with A-opener
1.10 Causes of damage
Once the lock is installed, do not drill through thedoor.
Do not install the spindle using force. As soon as it becomes apparent that force has been
used, the lock must be replaced.
If necessary, lubricate locking elements with aspray-on lubricant.
Do not paint over locking elements. Only apply pressure to the lever handle in the
direction of activation. Max. force 150 N. The lock must be locked only with the associated key.
The lever handle and key must not be operated at the same time.
Double-leaf doors must not be forced open when locked.
Locking elements must not be misused to hold the door open.
Introduction
506.2017
KFV
Operating instructions AS 3600/AS 3600 TA/AS 3600 T4/ AS 3600 T3/ AS 3600 with A-opener
2. Safety
Before starting the operating steps, read the following safety instructions carefully. They are designed to keep you safe and prevent hazards, injuries and material losses.
2.1 Misuse
There is a risk of being locked out if the daytime function is not activated completely.
• If the door closes accidentally and the daytime function on the day latch is not activated, the main lock latch engages and keeps the door closed.
• If the door closes accidentally and the daytime function on the main lock bolt is not activated, the automatic locking mechanism is activated. The falling bolt and hook bolt move to the locking position.
The door can then only be opened from the outside with a key in both cases!
BOTH functions must always be activated.
Safety
6 06.2017
KFV
Loading...
+ 14 hidden pages