Siegenia Aeruotube WRG smart,Aeruotube AZ smart Operating Instructions Manual

AERO
Wall-mounted ventilator with optional supply and exhaust air function, heat recovery and temperature/humidity sensor.
AEROTUBE WRG smart AEROTUBE AZ smart
Door systems
Comfort systems
ORIGINAL OPERATING INSTRUCTIONS
2
AEROTUBE Original operating instructions
11.2016
Contents
Target group of this documentation ................................................................................................................................................ 3
Intended use .................................................................................................................................................................................... 3
Dimensions ...................................................................................................................................................................................... 3
Safety notes ..................................................................................................................................................................................... 4
Scope of delivery / equipment ....................................................................................................................................................... 5
Installation ....................................................................................................................................................................................... 6
Unit function ..................................................................................................................................................................................11
Operation general ........................................................................................................................................................................12
Operation via button on the device ..............................................................................................................................................13
Operation via smartphone or tablet ............................................................................................................................................. 13
Care and maintenance ................................................................................................................................................................. 14
Accessories ...................................................................................................................................................................................19
Rectification of malfunctions .........................................................................................................................................................19
Technical specifications ................................................................................................................................................................20
Liability .......................................................................................................................................................................................... 22
Feedback on documentation ........................................................................................................................................................ 22
EU Declaration of Conformity with regard to CE marking ..........................................................................................................23
Original operating instructions AEROTUBE
11.2016 3
Target group of this documentation
• This documentation is intended for use by specialists and end users.
• All work described in this document is to be performed by experienced professionals with training and practice in the installation, commissioning and maintenance of ventilation units. Safe and proper assembly of this unit is not possible without expert knowledge.
• All instructions on operation and maintenance described here are intended for end users.
• After the successful assembly and installation, the installation company is committed to handing over the operating instructions to the end user.
Intended use
• Use the AEROTUBE exclusively for the ventilation of closed rooms (kitchen, bathroom, living rooms and bedrooms).
• The AEROTUBE is not suitable for dehumidification (e.g. for the drying of new buildings).
• The unit must always be installed by an experienced specialist, in accordance with the installation and planning documents of SIEGENIA. The installation instructions in this document must be complied with at all times.
• Be sure to attach an original SIEGENIA weather grille to protect the device from the outside.
• Do not install the unit in contaminated rooms and ensure that no hazardous substances can be drawn in.
• Do not use the AEROTUBE in environments with corrosive or explosive atmospheres (dust, vapour or gas).
• The unit is not suitable for use in swimming pools and/or damp locations.
• The AEROTUBE must be mounted in a vertical position. Mounting on inclines (e.g. walls and ceilings), is not permissible.
• If the unit is to be used in a room with a heating unit that draws air from the room, prior authorisation must be obtained from the proper authorities, such as the officially appointed district chimney sweep.
• Only operate and/or store the AEROTUBE at temperatures between -15°C and +40°C.
• Use the unit only with original accessories from SIEGENIA.
• Observe the safety regulations for operating electrical equipment and, if necessary, for ladders, steps and work overhead or at certain heights.
• Use the unit only when it is in a technically sound condition.
• Do not modify the unit's components in any way.
• Please do not put any objects on top of the unit.
• Do not use the device as a seat.
• Make sure that air can flow in and out at the two outer sides without impedance. Do not hang any textiles or paper or similar items over the air inlet and outlet ports and do not place any objects directly in front of or beside the unit. Do not insert any objects into the openings of the unit.
• Do not remove any covers or unit components that are not defined in the "Maintenance" chapter. Do not remove the cover of the connecting clamps inside the unit.
• The unit must be checked by a specialist in the event of a fault.
Dimensions
• All the dimensions in this documentation are specified in mm.
4
AEROTUBE Original operating instructions
11.2016
Safety notes
• This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance must not be carried out by children without supervision.
• Electrically operated unit. Risk of fatal injury from electric shock or fire. To prevent personal injury or damage to property, always comply with the following instructions.
- Insert the Euro mains plug of the standard connecting cable only into a suitable 230VAC mains power supply socket.
- If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, its customer service or an equally qualified person to eliminate hazards.
- Only a qualified electrician may perform any work on the 230V AC mains power supply that is required in order to connect the unit.
- All-pole safety isolation is required if the customer is routing the mains cable.
- Current local regulations (such as those of the VDE in Germany) must be observed.
- Relevant country-specific regulations with regard to installation, functional testing, repair and maintenance of electrical products must be strictly followed for all work carried out on the voltage supply system or house wiring system.
- Should a solid object or any liquid get inside the unit, stop operation immediately and disconnect the unit from the mains power supply.
• Hazard due to third party attacks on SIEGENIA WLAN devices! Please observe the following notes to protect your system against attacks by third parties:
- Every SIEGENIA WLAN device is protected by two passwords (user and administrator). It is essential that you change these passwords after the initial setup. Do not leave in the default setting.
- If the SIEGENIA WLAN devices are integrated in your home WLAN, this must be encrypted for operation.
- Please choose secure passwords consisting of lower case and capital letters, numbers and special symbols.
• Slipping hazard – In order to prevent personal injury, it is essential to ensure that condensate does not flow onto pavements and freeze during outdoor temperatures below 0°C.
Original operating instructions AEROTUBE
11.2016 5
Scope of delivery / equipment
Item Designation AEROTUBE
WRG smart AZ smart
Scope of delivery
1
Front panel
2
Casing with slider
3
Mounting cover
4
Axial ventilator
5
Pipe inset (2-part)
6
Filter holder
7
Filter G3
8
Heat storage/ceramic heat accumulator
9
Ventilation pipe Ø 160
10
Bag of screws (4 screws and dowels)
11
Translation of the original operating instructions
12
Weather grille (optional, see accessories page 19)
(
) ( )
Function
Heat recovery
Active exhaust and/or supply air operation (blower)
Passive exhaust air supply air operation (pressure differential)
Operation via SI Comfort app
Temperature and humidity sensor
Optional electrical locking slider
(
) ( )
10
1
11
12
2
AEROTUBE WRG smart
AEROTUBE AZ smart
3
4
5
7
9
3
3
4
5
6
7
8
9
3
6
AEROTUBE Original operating instructions
11.2016
Installation
Risk of injury due to pipe inset falling out.
Ensure that the pipe inset does not fall down. Proceed with caution.
• The installation site of the AEROTUBE should not be accessible to third parties.
• The AEROTUBE should be installed to be as free from interference as possible. The following interferences can have a negative influence on the WLAN signal:
- Water lines
- Stone and concrete walls
- Metal objects
- Air conditioning units
- Wireless devices (e. g. radio telephones, baby monitors, Bluetooth loudspeakers, etc.)
- WLAN networks on the same wireless channels (e. g. the neighbour's WLAN router)
• If energy-carrying cables are routed in parallel to data cables (ISDN, DSL, etc.), this could lead to interference e.g. in the speed of the data transmission.
1. Mark drill holes (room side)
Risk of damage to property by drilling holes through concealed cables or pipes!
Before installing the unit, use a suitable cable and pipe detector at the installation location to identify the presence of
concealed cables or pipes in the wall (such as water pipes).
2
1
6x
min. 400min. 400
Original operating instructions AEROTUBE
11.2016 7
2. Drill core hole
Note: To prevent condensate from discharging outwards, the hole must have an incline of 0.5–2°. However, the slope must
not exceed 3° as this would make it impossible to remove the pipe inset from the ventilation pipe for maintenance purposes.
≥ ø 162
0,5–2°
3. Drill fixing holes and route cable 4. Remove mounting cover and complete pipe inset
8
AEROTUBE Original operating instructions
11.2016
5. Shorten pipe 6. Insert pipe
Attention! The pipe must be at least 270 mm long.
X
X
7. Insulate pipe (according to requirement) 8. Seal pipe
Inside airtight seal Outside free-air seal
Loading...