Siegenia AEROPAC Original Operating Instructions

Window systems
Door systems
Comfort systems
AERO
Wall mounted ventilator with noise absorbtion.
deutsch english français nederlands русский
AEROPAC Original Operating Instruction
30 02.2016
deutsch english français nederlands русский
Target group of this documentation ...................................................................................................31
Appropriate Use ................................................................................................................................. 31
Safety information .............................................................................................................................. 32
Function ............................................................................................................................................... 33
Carton contents ..................................................................................................................................33
Installation ...........................................................................................................................................34
AEROPAC wave Unit Type: Start-Up .................................................................................................. 43
Operation ...........................................................................................................................................45
Care and maintenance .......................................................................................................................47
Accessories ......................................................................................................................................... 51
Technical Data .................................................................................................................................... 52
Product Liability ...................................................................................................................................54
Declaration of Conformity ..................................................................................................................55
Original Operating Instruction AEROPAC
02.2016 31
Target group of this documentation
This documentation is intended for use by specialists only. All work described in this document is to be performed by experienced professionals with training and practice in the assembly, installation and maintenance of ventilation units. Safe and proper assembly of this unit is not possible without expert knowledge.
Appropriate Use
• This unit is to be used exclusively for ventilating enclosed indoor spaces.
• The unit is not suitable for use in swimming pools and/or damp locations.
• Be sure to attach the supplied protective SIEGENIA weather grill from the outside.
• Do not install the appliance in contaminated rooms and ensure that no pollutants can be drawn in.
• If the unit is to be used in a room with a heating unit that draws combustion air from the room, prior
authorisation must be obtained from the proper authorities.
• Pay attention to appropriate possibilities such as adequately dimensioned overflow openings. We can provide you with advice on overflow openings on request (H45.WANS001INT).
• Maintain a room temperature of 0 °C – 40 °C.
• Use this unit only with original accessories from SIEGENIA.
• Installation of the unit must always be undertaken by a specialist, in accordance with the installation
and planning documentation from SIEGENIA.
• The assembly instructions contained in this manual are to be adhered to.
• Observe the safety regulations for working with electrical tools as well, where necessary, as those
for the use of ladders, steps, working above one‘s head and working at particular heights.
• Use the unit only in a technically perfect state.
• Do not make any changes on the components of the unit.
• Ensure that the air openings remain vacant and are not blocked by other equipment, furniture or
objects.
• Please do not place any objects on the appliance.
• Please ensure that the slider on the appliance is not left closed over a long period of time (several
days), to enable minimum ventilation and also prevent insects from nesting there.
• At least one of the two ventilation openings must be open while the blower is switched on.
• In case of defects the unit must be checked by a specialist.
deutsch english français nederlands русский
AEROPAC Original Operating Instruction
32 02.2016
Safety information
• This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance must not be carried out by children without supervision.
• Do not allow children to play with the unit.
• Electrically operated unit. Danger of death by electrocution or fire.
To avoid injury and material damage it is mandatory to observe the following instructions:
- Only insert the Europlug of the standard connecting cable into a suitable 230 V AC socket.
- If the mains connection cable for this device is damaged, it must be replaced by SIEGENIA,
their customer service department, or similar qualified personnel in order to prevent hazards.
- Should work on the 230 V AC mains power supply be necessary in order to connect the device,
it may only be performed by a qualified electrician.
- An all-pole safety isolation is required when the customer lays the power cable. The fuses may
need to be removed.
- Current local regulations (such as VDE 0100 in Germany) must be observed. Relevant
country-specific regulations must be strictly followed for all work on the voltage supply system or house wiring system.
- Should a hard object or fluid get into the interior of the device, stop operation immediately and
disconnect the device from the mains power supply.
deutsch english français nederlands русский
Original Operating Instruction AEROPAC
02.2016 33
Function
The low-noise AEROPAC wall-mounted ventilator uses an electrically operated blower to draw in fresh air from the outside and provide controlled and energy-efficient fresh filtered air inside.
When the blower is switched off, the unit equalises the pressure of the indoor and outdoor air to allow fresh air from the outside to flow inside (pressure differential principle).
Various filters may be used, depending on the intended use of the unit:
AEROPAC G3 dust filter For coarse dust AEROPAC F5 dust filter For pollen/fine dust AEROPAC activated carbon filter E.g. exhaust fume odours
Features
The AEROPAC offers the following features:
• Sound absorption
• Low internal noise
• Filters dust and exhaust fume odours
• Filter change indicator
• Adjustable airflow
• Timer function
The AEROPAC wave unit type offers the following additional features:
• Device control by means of a Z-Wave wireless network
The AEROPAC DD unit type exchanges the air in a room without a blower (pressure differential principle).
Carton contents
• AEROPAC wall-mounted ventilator with G3 dust filter
• Original Operating Instruction plus drilling template
• Mounting kit consisting of two screws, two dowels and one stopper
• Weather grill F. (made of plastic)
• PVC ventilation pipe, Ø 80 mm, 500 mm long
deutsch english français nederlands русский
AEROPAC Original Operating Instruction
34 02.2016
Installation
Installation requirements
• If the unit is to be installed in a room with a heating unit that draws air from the room (e.g. a fireplace), prior authorisation must be obtained from the proper authorities.
• Suitable location for installation:
- In the vicinity of a 230 V AC power connection (max. cable length: 4.5 m)
- When a permanent mains connection is used: over a flush-mounted box
- Not in the immediate vicinity of radiator thermostats
• On a smooth, even wall.
• Ensure that no cables or pipes are concealed inside the wall at the unit’s designated position.
• Keep the unit free from dirt during installation and before start-up.
• To prevent damage to the high-quality surface of the unit, it is advisable to wear suitable gloves
during the installation.
Recommended unit position
min. 350 mm
max. 1000 mm
min. 300 mm
deutsch english français nederlands русский
Original Operating Instruction AEROPAC
02.2016 35
Step1: Marking the holes and drilling the core hole
Risk of damage to property by drilling through concealed cables or pipes.
Before installing the unit, use a suitable cable and pipe detector at the installation location to
identify the presence of concealed cables or pipes in the wall (such as water pipes):
1. Use a level to ensure the drilling template (included) is vertical (see the installation requirements) and fix to the wall.
2. Mark two drilling mounting holes and the core hole bore (for the supply air from outside) on the wall. If required, mark an additional mounting drill hole (B) that may be used to additionally secure the unit.
B
mm
3. Drill the core hole: (Ø =>82 mm). Using a hammer drill at an angle of approx. 2° to 5°, drill a hole through to the outside wall.
Attention! If the AEROPAC is combined with a reveal channel, follow the appropriate assembly instructions.
Room side
Outside
deutsch english français nederlands русский
AEROPAC Original Operating Instruction
36 02.2016
Step 2: Drilling the mounting holes and inserting the fixing screws
1. Drill the two marked mounting holes and, if required, the additional mounting hole (B) (all drilled holes should have a diameter of 8 mm and be at least 45 mm deep).
B
2. Insert two S8 dowels (included in the delivery) into the drill holes (B). Note: depending on the type of wall (e.g. plasterboard), suitable dowels may need to be provided by the customer for inserting into the drill holes.
3. Insert the two supplied countersunk wood screws (DIN 7995 – 5 x 50 mm) into the dowels and screw in so that each screw protrudes by 8 mm.
B
Step 3: Inserting the PVC ventilation pipe into the core boring
1. Shorten the PVC ventilation pipe (included in the delivery) to the thickness of the wall (dimension X).
2. Push the ventilation pipe into the core boring so that both ends are flush with the wall.
deutsch english français nederlands русский
Original Operating Instruction AEROPAC
02.2016 37
Installation recommendations for the PVC ventilation pipe
The gap between the PVC ventilation pipe and the core boring must be properly sealed inside the room and outside.
Please note the following:
• Ensure that the gap to be sealed is wide enough to allow for movement in the materials.
• Insulate the gap (heat insulation)
• Seal the gap outside so that it is resistant to driving rain
• Seal the gap inside the room so that it is air-tight
• The following principle applies: “inside tighter than outside”
Heat insulation
For gaps over >6 mm, it is essential that the insulation is free of voids and suitable insulating material is used for all wall systems.
Clean the gap. Ensure that the holding surfaces are clean and free of grease. In particular, remove any residues of insulating material.
Insert the insulating material
PVC-pipe ø 80 mm
Gap > 6 mm
Core hole bore, e. g. ø 93 mm