Siegenia AEROMAT VT WRG 1100, AEROMAT VT WRG 1100 SMART Operating Instructions Manual

AERO
Sound absorbing ventilator with heat recovery.
AEROMAT VT WRG 1100
Window systems
Door systems
ORIGINAL OPERATING INSTRUCTIONS
Original operating instructions AEROMAT VT WRG 1100
10.2018 3
Contents
1. Target group of this documentation ........................................................................................................................................... 4
2. Intended use................................................................................................................................................................................ 4
3. Dimensions .................................................................................................................................................................................. 5
4. Safety notes ................................................................................................................................................................................ 5
5. Scope of delivery / equipment .................................................................................................................................................. 6
6. Installation ................................................................................................................................................................................... 7
7. Mains supply ............................................................................................................................................................................10
8. Unit function .............................................................................................................................................................................. 12
9. Membrane key and LED display ..............................................................................................................................................13
10. Commissioning ....................................................................................................................................................................... 14
11. Operation ............................................................................................................................................................................... 14
12. Care and maintenance ..........................................................................................................................................................18
13. Rectification of malfunctions ..................................................................................................................................................23
14. Accessories ............................................................................................................................................................................. 23
15. Technical specifications ..........................................................................................................................................................24
16. Feedback on documentation ................................................................................................................................................. 25
17. EU Declaration of Conformity with regard to CE marking .................................................................................................... 26
4
AEROMAT VT WRG 1100 Original operating instructions
10.2018
1. Target group of this documentation
• This documentation is intended for use by specialists and end users.
• All instructions concerning assembly, installation and repairs described in this document are to be performed exclusively by experienced professionals with training and practice in the installation, commissioning, servicing and maintenance of decentralised ventilation units.
• All instructions on operation, care and maintenance as well as the rectification of malfunctions described here are intended for specialists end users.
• After the successful assembly and installation, the installation company is committed to handing over the operating instructions to the end user.
2. Intended use
• The AEROMAT VT WRG 1100 is intended for installation in the exterior windows/walls of permanent structures in accordance with our installation and design documents and the specifications of our operating instructions and is only suitable for the ventilation of enclosed rooms.
• The AEROMAT VT WRG 1100 must be installed in the intended installation position (horizontal or vertical). The intended installation position results from the weather grille preassembled in the factory.
Weather grille: 911 HW Installation position:
Horizontal
Weather grille: 911 HW-g (concealed installation in the wall) Installation position: Horizontal
Weather grille: 911 CW Installation position:
Horizontal
• Do not use the AEROMAT VT WRG 1100 in environments with corrosive or explosive atmospheres (dust, vapour or gas).
• Do not install the unit in contaminated rooms and ensure that no hazardous substances can be drawn in.
• The AEROMAT VT WRG 1100 may be installed in damp locations in protection class 2; however, the socket used must be in at least protection class 3.
• If the AEROMAT VT WRG 1100 is to be used in a room with a heating unit that draws air from the room, prior authorisation must be obtained from the proper authorities, such as the officially appointed district chimney sweep. Intended use requires that any combustion air lines and exhaust gas systems of solid fuel heating units must be able to be shut off.
• Only operate and/or store the AEROMAT VT WRG 1100 at temperatures between ‒ 15°C and +40°C.
• Use the AEROMAT VT WRG 1100 only with genuine accessories from SIEGENIA.
• Comply with the safety regulations for operating electrical equipment and, if necessary, for ladders, steps and work overhead or at certain heights.
• Use the AEROMAT VT WRG 1100 only when it is in a technically sound condition.
• Do not modify the unit's components in any way.
• Ensure that the device's ventilation openings are kept free and are not blocked by other equipment, furniture or objects.
Original operating instructions AEROMAT VT WRG 1100
10.2018 5
• Please do not put any objects on top of the unit.
• If the AEROMAT VT WRG 1100 is fitted with filters, you must make sure that these cannot become the source of elements that are odorous and harmful to health; this also includes regular inspection and replacement of filters.
• In the event of a fault, only have the AEROMAT VT WRG 1100 repaired by experienced specialists with training and practice in the repair of ventilation units.
• Any use or application of this product that is not in accordance with its proper use, or any adaptation of or modifications made to the product and its associated components, for which the express consent of SIEGENIA has not been obtained, are strictly prohibited. SIEGENIA accepts no liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.
3. Dimensions
• All the dimensions in this documentation are specified in millimeter (mm).
4. Safety notes
• This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance may not be carried out by unsupervised children.
• Electrically operated unit. Risk of fatal injury from electric shock or fire. To prevent personal injury or damage to property, always comply with the following instructions:
- Work on a 230 V AC mains power supply may only be performed by a qualified electrician.
- If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, the company's customer service
department, or similarly qualified personnel in order to prevent personal injury or damage to property.
- All-pole safety isolation is required if the customer is routing the network connection cable.
- All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regulations
(e.g., VDE 0100) and any relevant country-specific requirements.
- Relevant country-specific regulations must be strictly followed for all work carried out on the voltage supply system or house
wiring system.
- Should a solid object or any liquid get inside the unit, stop operation immediately and disconnect the
AEROMAT VT WRG 1100 from the mains power supply: Check whether the AEROMAT VT WRG 1100 is damaged If necessary, repair work can be performed by experienced professionals
• Hazard due to third party attacks on SIEGENIA WLAN devices! Please observe the following notes to protect your system against attacks by third parties:
- Every SIEGENIA WLAN device is protected by two passwords (user and administrator). It is essential that you change these
passwords after the initial setup. Do not leave in the default setting.
- If the SIEGENIA WLAN devices are integrated in your home WLAN, this must be encrypted for operation.
- Please choose secure passwords consisting of lower case and capital letters, numbers and special symbols.
6
AEROMAT VT WRG 1100 Original operating instructions
10.2018
5. Scope of delivery / equipment
Item Designation AEROMAT VT WRG 1100 AEROMAT VT WRG 1100
smart
Var.1 Var. 2 Var. 3 Var. 4
Scope of delivery
1
Unit
2
Translation of the original operating instructions
3
SIEGENIA Comfort app* quick start instructions
Function
Heat recovery
Automatic mode
Air quality sensor and/or Temperature and humidity sensor
Operation via SIEGENIA Comfort app
Optional electrical locking slider
(
) ( ) ( ) ( )
* The quick start instructions for the SIEGENIA Comfort app are located behind the front panel (To open the front panel, see page 19).
2 31
-
Original operating instructions AEROMAT VT WRG 1100
10.2018 7
6. Installation
6.1 Prerequisites for installation
• The position from which the outdoor air is drawn in must be selected so that any nearby emission sources have as little impact as possible on the quality of the air being drawn in.
• The maximum permissible area load is 1,000 kg per running metre of ventilator length.
• Installation options:
Installation in the window sill Concealed installation in the wall
with wall duct
Installation in the window lintel Concealed installation in the window lintel
6.2 Additional requirements for AEROMAT VT WRG 1100 smart
• The AEROMAT VT WRG 1100 smart should be installed to be as free from interference as possible. The following interferences can have a negative influence on the WLAN signal:
- Water pipes
- Stone and concrete walls
- Metal objects
- Air conditioning units
- Wireless devices (e. g. radio telephones, baby monitors, Bluetooth loudspeakers, etc.)
- WLAN networks on the same wireless channels (e. g. the neighbour's WLAN router)
• If energy-carrying cables are routed in parallel to data cables (ISDN, DSL, etc.), this could lead to interference e.g. in the speed of the data transmission.
AEROMAT VT
AEROMAT VT
AEROMAT VT
AEROMAT VT
8
AEROMAT VT WRG 1100 Original operating instructions
10.2018
6.3 Installation sequence
1. Remove the AEROMAT VT WRG 1100 carefully from the packaging and do not place it on the weather grille or front panel. We recommend storing the unit on a soft surface (e.g. cardboard or sheet) during installation.
2. Close the sliders on the front to prevent dirt (e.g. dust) from entering the unit during installation. If the AEROMAT VT WRG 1100 does not have sliders, tape up the recesses in the front panel with film.
3. Make sure that no dirt and liquids can get inside the AEROMAT VT WRG 1100 including the weather grille prior to the installation of the exterior insulation or cladding. Attention! According to the installation location, it is therefore necessary to adhere the AEROMAT VT WRG 1100 at points where rain could permeate.
Example
"Concealed installation in the wall
with wall duct"
Example
"Concealed installation in the lintel"
AEROMAT VT
Film
Adhesive tape
Exterior insulation
Adhesive tape
AEROMAT VT
Exterior insulation
Film
Adhesive tape
Adhesive tape
4. Install the AEROMAT VT WRG 1100 in its intended installation position and seal it in accordance with the installation directives applicable on site.
5. Check AEROMAT VT WRG 1100 for cleanliness prior to starting it up. Clean if necessary (see "care and maintenance" on page 17).
Attention! Only drill in through-holes for wall plugs and screws in the area indicated (see marker tape). Important! Remove any marker tape that is visible after installation.
6.4 Interruption of installation work
Prior to stopping work or while work is interrupted, protect open ends or areas so that no dust or moisture can enter.
Original operating instructions AEROMAT VT WRG 1100
10.2018 9
6.5 Mounting angle
Screw on the mounting bracket in the area indicated (marker tape) or fasten it to the casing profiles with a rivet. We
recommend that you use SIEGENIA aluminium mounting angles.
AEROMAT VT WRG 1100 with 911 CW weather grille
AEROMAT VT WRG 1100 with 911 HW weather grille
Dimension Meaning
a Mounting area for bracket
b Screw and drilling area (e.g. for wall plugs or mounting screws)
c Overall depth
A Bracket 20 x 20 x 2 (optional)
B Z profile (optional)
C Stop profile (optional)
6.6 Z profile
First, fix the Z profile (optional) to the weather grille using double-sided tape, then drill and rivet it.
10
AEROMAT VT WRG 1100 Original operating instructions
10.2018
7. Mains supply
Depending on the design, the AEROMAT VT WRG 1100 is connected to a suitable socket of the 230-V AC mains power supply using the Euro plug or directly to the 230-V AC mains power supply using an external switch.
7.1 Socket connection
Important: When installed in damp locations, the socket for the AEROMAT VT WRG 1100 must be installed in at least
protection class3.
Insert the Euro plug into a suitable 230-V AC mains power supply.
7.2 External switch connection
Exposed electrical components. Risk of fatal injury from electric shock or fire.
Work on a 230 V AC mains power supply may only be performed by a qualified electrician. All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE
regulations (e.g. VDE 0100) and any relevant country-specific requirements.
Switch off or unscrew the security devices.
Important: If the AEROMAT VT WRG 1100 is connected directly to the 230-V AC mains power supply, the customer must install a mains isolator.
Original operating instructions AEROMAT VT WRG 1100
10.2018 11
7.3 Wiring diagram AEROMAT VT WRG 1100 (3-stage rotary switch and changeover switch if required)
L1 N
18 17
16 15
13
11
10
9
8 7
14
12
6 5 4 3 2 1
4321
0
321
S1
S2
Level 1
Flat ribbon cable
20 V∼ 20 V∼
Red Black Yellow
Red Black Yellow
Supply air + Supply air ―
Exhaust air + Exhaust air ―
+ 24 V
button
button
button
Level 2
Level 1
Inputs
Blower
Supply
air
Exhaust
air
Slider
Trans-
former
Transformer
Level 2
Level 3
Auto
Black
Grey
White
Red
Blue
Brown
Switch Value
S1 Blower level 0, 1, 2, 3 S2 Automatic*
Colour Value
Black Blower level 1 Grey Blower level 2 White Blower level 3 (power level) Red Automatic* Brown L1 Blue N
*only with AEROMAT VT WRG 1100 Var. 2 and Var. 4 (with sensors)
7.4 Wiring diagram AEROMAT VT WRG 1100 (series switch)
L1 N
18 17
16 15
13
11
10
9
8 7
14
12
6 5 4 3 2 1
4321
S1
S2
Black
Grey
Blue
Brown
Level 1
Flat ribbon cable
20 V∼ 20 V∼
Red Black Yellow
Red Black Yellow
Supply air + Supply air ―
Exhaust air + Exhaust air ―
+ 24 V
button
button
button
Level 2
Level 1
Inputs
Blower
Supply
air
Exhaust
air
Slider
Trans-
former
Transformer
Level 2
Level 3
Switch Value
S1 Blower level 1 S2 Blower level 2 S1 + S2 Automatic*
Colour Value
Black Blower level 1 Grey Blower level 2 Brown L1 Blue N
*only with AEROMAT VT WRG 1100 Var. 2 and Var. 4 (with sensors)
12
AEROMAT VT WRG 1100 Original operating instructions
10.2018
8. Unit function
8.1 Ventilation with fans and heat recovery (schematic diagram)
• The outside air (1) is drawn in through the outside air filter (2) or insect grille (2, optional) using the supply air fan (3) and enters the room as supply air (4).
• The exhaust air (5) is drawn in through an exhaust air filter (6) using the exhaust air fan (7) and makes its way outside as exhaust air (8).
• Both streams of air are drawn through the heat exchanger (9). Here, particularly during cold times of the year, the outside air is pre-heated by the warm exhaust air before it enters the room as supply air.
No. Element No. Element
1 Outside air 6 G3 exhaust air filter
2 F7 outside air filter or insect grille (optional) 7 Exhaust air fan
3 Supply air fan 8 Exhaust air
4 Supply air 9 Heat exchanger
5 Exhaust air 10 Power supply, control, cable outlet, membrane key
8.2 Ventilation without fans
• When the fans are switched off and the sliders are open, the unit equalises the pressure of the indoor and outdoor air to allow fresh air from the outside to flow into the room (pressure differential ventilation). Because the fans are not moving, the air in both air canals flows in the same direction, meaning that air is generally drawn in from the outside into the room – depending on the weather, the wind pressure increases the air flow into the room. Heat recovery does not take place when the fans are not used for ventilation.
8.3 Operation in automatic mode (only for AEROMAT VT WRG 1100 Var. 2 and Var. 4 - with sensors)
• AEROMAT VT WRG 1100 automatically switches to blower levels 0, 1 or 2 according to the air quality, the temperature and the air humidity.
• In automatic mode, the fans are controlled according to the humidity and temperature inside the room if an indoor sensor has been installed. The levels are based on comfort criteria.
• If indoor and outdoor sensors are connected, the room is ventilated if the absolute water content of the air outside is lower than that of the air inside (Example: Automatic ventilation will not take place if the outside air is relatively warm and humid).
• If several sensors are connected, the highest required blower level is always selected.
*
VOC are volatile organic compounds in the form of gases, e.g. cigarette smoke, perspiration, kitchen odours, etc.
Original operating instructions AEROMAT VT WRG 1100
10.2018 13
9. Membrane key and LED display
9.1 Operating status
Membrane key/LED Operating status
2 LEDs flash red Membrane key flashes blue
Calibration of the sensors
Blower level 0 (device is switched off)
1 LED lights up red Blower level 1
2 LEDs light up red Blower level 2
2 LEDs flash red Blower level 3
1)
(power level)
Membrane key lights up blue
Automatic mode: Blower level 0
2)
(device is ready for operation)
1 LED lights up red Membrane key lights up blue
Automatic mode: blower level 1
2 LEDs light up red Membrane key lights up blue
Automatic mode: blower level 2
1)
The power level can only be controlled manually and is not available in automatic mode.
2)
In automatic mode, the fans are not switched off, but continue to run at a minimum level.
9.2 Malfunctions
Malfunctions are displayed in addition to the current operating status.
Membrane key/LED Malfunction Solution
1 LED flashes red
Frost protection function (Outside temperature below − 15 °C):
• Supply air fan is switched off
• Exhaust air fan continues to run
As soon as the outside temperature increases above -15°C again, the device switches to the last level to be used.
2 LEDs flash red alternately
Air quality sensor or sensor is defective.
Contact your specialist company.
Membrane key flashes blue
Filter soiled
Replace the filter (see page 20) Please note: Filters must be replaced not cleaned.
14
AEROMAT VT WRG 1100 Original operating instructions
10.2018
10. Commissioning
10.1 Automatic calibration of the air quality sensor (AEROMAT VT WRG 1100 Var. 2 and Var. 4)
• The sensors are calibrated automatically as soon as the AEROMAT VT WRG 1100 is connected to the power supply (and also following a power failure).
• 2 LEDs flash red and the membrane key flashes blue during the calibration.
• The calibration is completed after approx. 20 min.
Requirements for a faultless calibration
• The room must be well aired before the calibration.
• The room temperature must be between 5°C and 40°C.
• There should be no persons or animals in the room.
• The membrane key must not be activated during the process.
11. Operation
11.1 Ventilation without fans
1. Open both sliders
2. Set the blower level to 0
11.2 Ventilation with fans
1. Open both sliders
2. Set the required blower level using either the membrane key or the external switch
2.
1.
External switchMembrane key
(left)
Original operating instructions AEROMAT VT WRG 1100
10.2018 15
11.2.1 Adjustment of the blower level (using the membrane key)
• By pressing the membrane key several times, you can activate the required blower levels and automatic mode (relaying).
• The automatic mode is only available in designs with sensors (AEROMAT VT WRG 1100 Var. 2 and Var. 4).
• Following a power failure, the AEROMAT VT WRG 1100 switches to the last level to be used (automatic sensor calibration is performed first in units with sensors, see page14).
Switching sequence
AEROMAT VT WRG 1100 − Var. 1 and Var. 3 (without sensors)
Blower level 0 Blower level 1 Blower level 2 (Power level)
AEROMAT VT WRG 1100 − Var. 2 and Var. 4 (with sensors)
Blower level 0 Blower level 1 Blower level 2 Power level
1)
Automatic
1)
The power level can only be controlled manually and is not available in automatic mode.
16
AEROMAT VT WRG 1100 Original operating instructions
10.2018
11.2.2 Adjustment of the blower level (using the external switch)
• By pressing the external switch, you can activate the required blower levels and automatic mode directly (without relaying).
Attention! If the membrane key is pressed when an external switch is installed, the next blower level will be activated (for switching sequence see page 15). Pressing the external switch again takes you back to the required blower level or automatic mode.
• The automatic mode is only available in designs with sensors (AEROMAT VT WRG 1100 Var. 2 and Var. 4).
• Following a power failure, the AEROMAT VT WRG 1100 switches to the last level to be used (sensor calibration is performed first in units with sensors, see page14).
AEROMAT VT WRG 1100 − Var. 1 and Var. 3 (without sensors)
Recommendation: use a 3-stage rotary switch provided onsite.
0
1
2
3
0
1
2
3
0
1
2
3
0
1
2
3
Blower level 0 Blower level 1 Blower level 2 (Power level)
AEROMAT VT WRG 1100 − Var. 2 and Var. 4 (with sensors)
Recommendation: use a changeover switch in combination with a 3-stage rotary switch provided onsite.
Auto
Manuell
0
1
2
3
0
1
2
3
Auto
Manuell
Auto
Manuell
0
1
2
3
Auto
Manuell
0
1
2
3
Auto
Manuell
0
1
2
3
Blower level 0 Blower level 1 Blower level 2 Automatic(Power level)
AEROMAT VT WRG 1100 − all versions
Recommendation: use the SIEGENIA type VT series switch („14. Accessories“ see page 23)
0 0
1 2
-Au- -to-
0
0
1
2
-Au-
-to-
0
0
1
2
-Au-
-to-
0 0
1 2
-Au- -to-
Blower level 0 Blower level 1 Blower level 2 Automatic*
*only with AEROMAT VT WRG 1100 Var. 2 and Var. 4 (with sensors)
Original operating instructions AEROMAT VT WRG 1100
10.2018 17
11.3 Operation via smartphone or tablet (AEROMAT VT WRG 1100 smart only)
AEROMAT VT WRG 1100 smart can be controlled via tablet or smartphone and offers additional device functions via the SIEGENIA Comfort app.
11.3.1 Teaching in the device
Please follow the enclosed quick start instructions (H47.MOTS005EN) to integrate the device in your home WIFI.
11.3.2 Device functions in the app
Blower performance
• The blower performance can be set manually.
• On application of the automatic mode, the manually adjusted blower performance is overridden.
Automatic mode
• For information on the automatic mode, see page 13.
Warning (replace filter)
• As soon as a filter replacement is required, this will be indicated as a warning.
Temperature and air humidity
• The temperature of the exhaust air and supply air is indicated in degrees Celsius (°C).
• The air humidity of the exhaust air and supply air is indicated in percent (%).
• The air quality is indicated in the form of a traffic light:
- Red = bad air quality
- Yellow = mediocre air quality
- Green = good air quality
18
AEROMAT VT WRG 1100 Original operating instructions
10.2018
12. Care and maintenance
Electrically operated unit. Risk of fatal injury from electric shock or fire.
To prevent personal injury or damage to property, always comply with the following instructions:
Pull the mains plug out of the socket prior to every cleaning process or maintenance work. Never pull at the cable to
disconnect the device from the electricity grid.
For all devices with a fixed connection to the 230 V AC mains power supply, switch off all poles of the feeder. The fuses
may need to be removed.
12.1 Cleaning
Important: When cleaning the AEROMAT VT WRG 1100, do not allow liquids to get inside the unit.
• Never use cleaning agents that are aggressive or contain solvents, or sharp-edged objects, as these may damage the surfaces of the casing.
• Never clean the unit with a high-pressure cleaner or steam-jet cleaner.
• Clean the AEROMAT VT WRG 1100 with a cloth moistened with a mild soap solution or cleaning agent.
12.2 Maintenance intervals
Component Check and clean Replace
Insect screen Every 6 months
Air ducts and heat exchanger
3)
Every 12 months
Filter
4)
Every 12 months or when the filter
change notification illuminates
3)
Condensation does not generally develop. If the surface of the heat exchanger becomes wet for a short period, as can
happen in damp locations, for example, the moisture will dissipate quickly with the outgoing air.
4)
Filters must be replaced, not cleaned. Only use genuine filters from SIEGENIA. You can purchase replacement filters from
SIEGENIA or from specialist retailers.
Original operating instructions AEROMAT VT WRG 1100
10.2018 19
12.3 Removing the front panel
The figure below shows the opening direction for a AEROMAT VT WRG 1100 that has been installed horizontally.
1. Open the locking bolts on the right and left
2. Pull out the front panel
3. Slide the membrane key out sideways (if present)
4. Remove the front panel and place it on a soft surface (cardboard, sheet)
1.
2.
3.
4.
20
AEROMAT VT WRG 1100 Original operating instructions
10.2018
12.4 Replacing the outside air filter
1. Remove the front panel (see also page19)
2. Remove the retaining spring
3. Remove the exhaust air filter and dispose of it as household waste
4. Insert a new exhaust air filter
5. Reassemble the AEROMAT VT WRG 1100 in the reverse order
6. Hold down the membrane key for 5 seconds to reset the LED indicator (filter replacement indicator)
3.
2.
Original operating instructions AEROMAT VT WRG 1100
10.2018 21
12.5 Replacing the outdoor air filter / cleaning the insect grille (subject to version)
1. Remove the front panel (see also page 19)
2. Remove the exhaust air filter (see also page 20)
3. Turn the supporting piece 90°
4. Remove the cover
5. Remove the insulation
6. Remove the filter compartment cover
7. Remove the foam padded wedge
8. Remove the outside air filter and dispose of it as household waste
9. Remove the insect grille, vacuum it and, if necessary, clean it under running water and leave it to dry
10. Insert the cleaned insect grille
11. Insert the foam padded wedge
12. Insert a new outside air filter
13. Reassemble the AEROMAT VT WRG 1100 in the reverse order
5.
6.
7.
9.
8.
4.
3.
22
AEROMAT VT WRG 1100 Original operating instructions
10.2018
12.6 Cleaning the heat exchanger
Caution! Sharp edges on the casing profile - Wear protective gloves!
1. Remove the front panel (see also page 19)
2. Remove the exhaust air filter (see also page 20)
3. Turn the supporting piece 90°
4. Remove the cover
5. Remove the foam padding
6. Remove the heat exchanger and clean it thoroughly under running water
7. Leave the heat exchanger to dry completely
8. Insert the cleaned heat exchanger so that it is sealed on all sides in the casing
9. Reassemble the AEROMAT VT WRG 1100 in the reverse order
6.
5.
4.
3.
Original operating instructions AEROMAT VT WRG 1100
10.2018 23
13. Rectification of malfunctions
In case of a malfunction, do not open the device or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your installation firm or SIEGENIA directly: Tel. +49 271 3931-0
Problem Possible cause Solution
AEROMAT VT WRG 1100 shows no reaction when button is pressed
No power supply Check power supply Wiring wrong/defective or cable
defective
Have the wiring checked by a qualified electrici­an
Power supply defective
Have the supply voltage checked by a qualified electrician
AEROMAT VT WRG 1100 smart does not respond to smartpho­nes/tablets
No WLAN connection to the router of the home network
Restart WLAN router of the home network
No WLAN connection to the smartphone/tablet
Restart smartphone/tablet
No WLAN connection to the AEROMAT VT WRG 1100 smart
Reset AEROMAT VT WRG 1100 smart:
1. Press membrane key 3 times briefly in succession
2. Then immediately press and hold the membra­ne key once (for approx. 4 seconds)
3. The AEROMAT VT WRG 1100 smart has been reset to the factory settings.
13.1 SIEGENIA Comfort app
You will find detailed operating information as well as information on how to rectify disturbances on the SIEGENIA Smartho­me Internet page.
https//smarthome.siegenia.com
14. Accessories
Designation Contents Material number
Filter set AEROMAT VT WRG 1100 1x outside air filter F7
1x exhaust air filter G3 1x retaining spring
L4270060-093010
Filter set NOx filter F7 (nitrogen dioxide, fine dust, pollen)
1x outside air filter NOx F7 1x exhaust air filter G3 1x retaining spring
L4270090-099010
Switch UP type:VT WHITE 1x series switch Type VT 131322
24
AEROMAT VT WRG 1100 Original operating instructions
10.2018
15. Technical specifications
The values can vary according to the specific equipment configuration.
AEROMAT VT WRG 1100
Var. 1 Var. 2 Var. 3 Var. 4
Sensors
WLAN module
Sound absorption (with sliders open)
1)
R
w-1.9
= 48 dB
D
n,e,w
= 55 dB
Max. permissible area load per linear metre of ventilator length
1,000 kg
Heat transition coefficient
2)
U = 0.55 W/m2K
Permissible operating temperature
‒15 °C to +40 °C
Outside air filter (if present)
F7, 193 x 88 mm
Exhaust air filter (if present)
G3, 330 x 90 mm
Effective air throughput
(with filter)
With blower level 1 With blower level 2 With blower level 3 (power level)
approx. 21 m3/h approx. 37 m3/h approx. 56 m3/h
Heat recovery efficiency
3)
max. 62%
Inherent noise
4)
at blower level 1 With blower level 2 With blower level 3 (power level)
LpA = approx. 21 dB(A) LpA = approx. 27 dB(A) LpA = approx. 38 dB(A)
Supply voltage
230 V∼
Unit operating voltage
24 V
Power consumption With blower level 1 With blower level 2 With blower level 3 (power level)
4W 7W
18W
5W 8W
20W
Mains supply
230 V
/ 50 Hz
Protection class II
Thermal protection in transformer
Length of connecting cable
1.50 m or 5m
1)
Measured in accordance with DIN EN 10140‒2 at an overall depth of 320 mm.
2)
calculated according to DIN EN ISO 6946.
3)
Based on EN 308.
4)
Measured in accordance with DIN EN ISO 3745 (with room insulation 8 db).
15.1 Dimensions
LL BT
100 mm
BA
room side
Ventilator length (LL) 1,100 to 1,400 mm, cable outlet A = 225 mm
1,401 to 3,000 mm, cable outlet B = 80 mm
Installation depth (BT) Min. 380 mm (subject to weather grille variant)
Original operating instructions AEROMAT VT WRG 1100
10.2018 25
15.2 Product data sheet (in accordance with EU Regulation 1254/2014)
a Manufacturer
SIEGENIA
b Model identification
AEROMAT VT WRG 1100
Var. 1 Var. 3 Var. 2 Var. 4
c Energy consumption (SEV);
Energy efficiency class (SEV class) (according to climatic zone warm / average / cold)
‒7.9 kWh/(m² · a); F
‒25.7 kWh/(m² · a); C
‒56.8 kWh/(m² · a); A+
‒13.5 kWh/(m² · a); E
‒34.5 kWh/(m² · a); A
‒71.1 kWh/(m² · a); A+
‒6.2 kWh/(m² · a); F
‒24.1 kWh/(m² · a); C
‒55.2 kWh/(m² · a); A+
‒13.5 kWh/(m² · a); E
‒34.5 kWh/(m² · a); A
‒71.1 kWh/(m² · a); A+
d Type
WLA / ZLA
e Type of drive
Multi-stage drive
f Heat recovery system
recuperative
g Degree of temperature change
52 %
h Highest air flow rate
56 m³/h
i Electrical input power
18 W 20 W
j Noise level
35 dB (A)
k Relative air flow rate
37 m³/h
l Relative pressure differential
m Specific input power
0.19 W/(m³/h) 0.23 W/(m³/h)
n Control factor / control typology
1.21 / 1 1.21 / 0.65 1.21 / 1 1.21 / 0.65
o Highest degree of inner and outer
leakage rate (inner / outer leakage)
9 % / 8 %
p
Mix rate (inner area / outer area)
‒13 % / 1 %
q Instructions for replacing filter
Replace filter see page21
r Instructions for the mounting of outside
air / exhaust air grilles (for one-directional ventilation units)
s Instructions for dismantling
t Pressure fluctuation sensitivity of the air
flow (at +20 Pa and –20 Pa)
12 % / 12 %
u Air tightness between inside and outside
1.4 m³/h
v Annual power consumption
3.013 kWh/a 1.8 kWh/a 3.7 kWh/a 1.8 kWh/a
w Annual saving of heating energy
(according to climatic zone warm / average / cold)
14.7 kWh/a
32.5 kWh/a
63.7 kWh/a
17.3 kWh/a
38.3 kWh/a
74.9 kWh/a
14.7 kWh/a
32.5 kWh/a
63.7 kWh/a
17.3 kWh/a
38.3 kWh/a
74.9 kWh/a
16. Feedback on documentation
We welcome your comments and suggestions on how to improve our documentation. Please email your comments to dokumen­tation@siegenia.com.
26
AEROMAT VT WRG 1100 Original operating instructions
10.2018
17. EU Declaration of Conformity with regard to CE marking
For our product AEROMAT VT WRG 1100, we confirm that the general safety of the defined product, in accordance with Directive 2001/95/EC, is compliant with the relevant protection requirements which are laid down in the Council Directives about electrical and electronic products.
The following listed test standards, which are harmonised in the relevant directives, have been employed for the evaluation:
a) 2014/30/EC EMC Directive
EN 55014-1:2006+A1:2009+A2:2011 EN 55014-2:1997+A1:2001+A2:2008 EN 61000-3-2:2014 EN 61000-3-3:2013
b) 2014/35/EC Low voltage directive
EN 60335-1:2012+A11:2014 EN 62233:2008
c) 2014/53/EC RED Directive
c1) Electromagnetic compatibility
EN 301489-1, V.1.9.2 EN 301 489-17, V.2.2.1 EN 61000-3-2:2014 EN 61000-3-3:2013
c2) Electrical safety - Establishment of information technology
EN 60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013
c3) Safety of persons in electromagnetic fields (10 MHz to 300 GHz)
EN 62479:2010
c4) Funkspektrumangelegenheiten - Datenübertragungsgeräte im 2,4- GHz-ISM-Band
EN 300 328 V1.9.1
d) 2006/42/EC Machinery Directive
EN 12100:2010 Risk assessment
e) 2011/65/EU RoHs
EN 50581:2012 Technical documentation on the evaluation of electrical and electronic devices with reference to the restriction of hazardous substances
This declaration is responsible for the manufacturers / importers based in the European Union submitted by:
SIEGENIA-AUBI KG Hardware and ventilation technology Duisburger Straße 8 57234 Wilnsdorf
Siegen, 2017-10-10
Contact your dealer:
Head O ce:
Industriestraße 1–3
57234 Wilnsdorf
GERMANY
Phone: +49 271 3931-0
Telefax: +49 271 3931-333
info@siegenia.com
www.siegenia.com
SIEGENIA worldwide:
Austria Phone: +43 6225 8301
Belarus Phone: +375 17 3143988
Benelux Phone: +31 85 4861080
China Phone: +86 316 5998198
France Phone: +33 3 8 9618131
Germany Phone: +49 271 39310
Great Britain Phone: + 44 2476 62 2000
Hungary Phone: +36 76 500810
Italy Phone: +39 02 935 3601
Poland Phone: +4 8 77 447 7700
Russia Phone: +7 495 7 211762
South Korea Phone: +82 31 7985590
Switzerland Phone: +41 33 346 1010
Turkey Phone: +90 21 6 5934151
Ukraine Phone: +380 4 4 4637979
You can fi nd address details for our
international sites at: www.siegenia.com
H47.FENS039EN/2