Mounting instructions
1 The ideal mounting height for door loudspeaker units lies between
1.40 and 1.60 m above the height of the finished floor.
Surface mounting, vertical or horizontal
2 f the plaster is highly uneven, additionally glue the four provided distance washers on the back panel of the surface mount housing GA 611-... over the screw holes on the already mounted washers (a). Open the cable entry (b) at the required position and glue the provided water deflector (c) like a roof on the back panel. Cable entries which are not required must remain closed. 3 Strip the connecting cable of its sheathing to max. 3 cm, insert through the back panel into the GA 611-... and fasten the housing on the wall. Pay attention to the indication „top“. 4 In order to prevent material fatigue of the catch lugs, ensure that they are not pushed backwards but correctly locked in position. If necessary, release these using a small screwdriver. 5 Remove the combination terminal strip from the module packaging, centre on the retaining plate turned by around 45° to the left, and lock into position with a quarter turn in the clockwise direction so that the terminal designations are legible vertically one above the other. 6 Press the connecting cables with the cable holding-down devices onto the floor of the housing. In the case of multiple-row units, fix the connecting wires using the wire holding brackets. Connect the unit using the relevant circuit diagram at the combination terminal strip. 7 Insert the mounting frame in such a way that the sealing film is located at the upper and right-hand edge of the mounting frame. When positioned horizontally, multiple-row housings must always be fitted from bottom to top, so ensuring that the
sealing film of the lower mounting frame overlaps that of the lower frame in fish-scale formation. When mounting vertically, ensure that the lateral film is positioned under the adjacent mounting frame. Clip the mounting frames in the surface mount housing using a light pressure. Catch lugs which are not required can be pressed out of the surface mount housing with a screwdriver and moved if required. 8 The mounting frame can be removed from the GA 611-... by pressing back the red catches. Note! Turning back can cause the catches to become locked in position. (see Fig. 4)
Flush mounting
9 Position flush mounting housings GU 611-... next to each other and connect using the provided system connectors. These connectors are mounted on a pin in the GU 611-... together with the cable holding­down device as injection moulded parts. The connectors can be broken off by a twisting action. 10 For combination frames bigger than 300 x 300 mm, the corners of the GU 611-... must be broken out. For in-row mounting involving a large number of units, specially produced combination frames are required.
11 (Not illustrated) Break out the cable gland between the housing units.
12 Plaster in the horizontal or vertical GU 611-... and insert the provided cardboard into the
GU 611-... . This serves as a plaster
protection and for reinforcement and remains in the housing until final assembly. Up to a maximum of 15 mm plaster height difference can be compensated. 13 Remove the combination terminal strip from the module packaging, centre on the retaining plate turned appr. 45° to the left and lock into position with a quarter turn in the clockwise direction so that the terminal designations are
legible vertically one above the other. 14 If combination frames of 600 X 500 mm and bigger are used, a cross is created in the substructure of the peripheral frame. There is an adjusting screw let into this cross, which allows the substructure to be supported away from the flush mount housing. Turn the adjusting screw inwards until the substructure is positioned parallel to the front. This guarantees that the front of the inserted module is correctly aligned. 15 Strip the connecting cables of their sheathing, press onto the floor of the housing, fix using the cable holding-down devices and connect the unit in accordance with the relevant circuit diagram at the combination terminal strip. 16 Insert the mounting frame together with the combination frame in such a way that the sealing profile of the combination frame is open towards the bottom. The mounting frame must be inserted in such a way that the sealing film is located at the upper and right-hand edge of the mounting frame. When positioned horizontally, multiple-row housings must always be fitted from bottom to top, so ensuring that the sealing film of the lower mounting frame overlaps that of the lower frame in fish-scale formation. When mounting vertically, ensure that the lateral film is positioned under the adjacent mounting frame. Clip the mounting frames in the surface mount housing using a light pressure. 17 Press the combination frame together with the mounting frame completely against the wall and screw in the flush mount housing using the provided quick-locking screws, turning a quarter turn to the right (until the stop).
Hollow wall mounting
18 Trace the cut-out for the flush-
mount housing GU 611-... . To do
this, lay the provided cardboard template flat on the wall and draw on the slit and drill hole markings.