Siebert XC610 Series Operating Instructions Manual

Series XC610
Digital displays for work safety Operating instructions
1 Safety instructions 3
Important information ......................................................................................................................................... 3
Warning notice.................................................................................................................................................... 3
Intended use ....................................................................................................................................................... 3
Special safety precautions for installation .......................................................................................................... 3
Qualified staff...................................................................................................................................................... 3
Protective low voltage ........................................................................................................................................ 4
Mounting and installation .................................................................................................................................... 4
Transport ............................................................................................................................................................ 4
Disposal .............................................................................................................................................................. 4
2 Important information 5
Copyright ............................................................................................................................................................ 5
Disclaimer ........................................................................................................................................................... 5
Liability ................................................................................................................................................................ 5
Cleaning ............................................................................................................................................................. 5
Accuracy of the display ...................................................................................................................................... 5
3 Important start-up instructions 6 4 Product description 7 5 Installation 8
Requirements to the installation site .................................................................................................................. 8
Installation material ............................................................................................................................................ 8
Disassembly of the fastening elements .............................................................................................................. 8
Mounting the unit ................................................................................................................................................ 8
Power supply connection ................................................................................................................................... 9
6 Connecting the configuration interface 10
Configuration via serial interface (RS232) ....................................................................................................... 10
Configuration via Ethernet ................................................................................................................................ 10
7 Start-up and configuration 11
Configuration of the display .............................................................................................................................. 11
Start-up and test ............................................................................................................................................... 11
Controls ............................................................................................................................................................ 11
8 Technical data 12 9 Service and Support 13
BAL XC610 1.12 2/13
DANGER!
Disregarding this warning notice leads to death or serious bodily harm.
WARNING!
Disregarding the warning notice can lead to death or serious bodily harm.
CAUTION!
Disregarding the warning notice can lead to minor physical injuries or property damage.
CAUTION!
Carefully seal the electrical equipment for safety reasons after commissioning.
1 Safety instructions
Important information
Read these operating instructions before starting the unit. They provide you with important information on the use, safety and maintenance of the units. This helps you to protect yourself and prevent damage to the unit.
During the lifetime of the unit keep the operating instructions in an accessible place at all times. Hand over the operating instructions to any future owner of the unit. It is to be considered as part of the product.
The manufacturer is not liable if the information in these operating instructions are not complied with.
Warning notice
Information intended to help you to avoid death, bodily harm or considerable damage to property is highlighted by the warning triangle shown here; it is imperative that this information be properly heeded.
Intended use
The unit is intended for use in photovoltaic systems. It may only be operated within the limit values stipulated by the technical data.
During configuring, installing, testing, commissioning and maintenance of the unit, the applicable standards and safety regulations have to be observed.
Trouble-free, safety operation of the unit requires proper transport, storage, installation, mounting and careful operation and maintenance of the unit.
Special safety precautions for installation
The key to seal the unit is included in the mounting kit.
Qualified staff
These operating instructions are intended for trained professional electricians familiar with the safety standards of electrical technology and industrial electronics.
Components inside the unit are voltage-carrying during operation. For this reason mounting and maintenance work may only be performed by professionally trained personnel while observing the corresponding safety regulations.
BAL XC610 1.12 3/13
For safety reasons and due to the required compliance with the documented unit properties the repair and replacement of components and modules may only be carried out by the manufacturer or an authorized specialized company.
Protective low voltage
The unit is powered by an included wall wart with 12 V. The unit has no power switch. It is in operation immediately after applying operating voltage.
Mounting and installation
The attachment options for the units were conceived in such a way as to ensure safe, reliable mounting. The user must ensure that the used fixing material guarantees, under the given surrounding conditions, a secure mounting.
When installing and commissioning please note the appropriate national and regional regulations.
Transport
The unit must be transported clean and dry in the original packing. The transport temperature must be between –40 °C and +70 °C. Temperature fluctuations of more than 20 °C per hour are non­permissible.
Disposal
The unit is made of low-emission materials and is therefore recyclable. For an environmentally safe recycling contact a certified waste management enterprise. Units or parts which are no longer needed are to be disposed of in accordance with the regulations in effect in your country.
BAL XC610 1.12 4/13
2 Important information
Copyright
This documentation is protected by copyright. All rights are reserved. No part of this documentation may be translated without written permission by Siebert
Industrieelektronik GmbH. No part of this documentation may be reproduced in any form by print, photocopy or other methods, or processed by using electronic systems, duplicated or disseminated.
Siebert®, LRD® and XC-Board® are registered trade marks of Siebert Industrieelektronik GmbH. As far as other product names or company names are mentioned in this documentation they may be trade marks or trade names of their respective owners.
Disclaimer
This documentation has been prepared with utmost care. For any mistakes we can not accept any liability. Corrections, improvement suggestions, criticism and suggestions are welcome. Please write to: editing@siebert-solar.com
Liability
Availability and technical specifications of the product are subject to change. The data specified is indicated solely for product description. They are not intended to be guaranteed in a legal sense.
Cleaning
For the care of the front panel use a scratch-free cloth. Do not push in the front pane during cleaning. The unit must not be cleaned with a steam cleaner.
Accuracy of the display
If the digital display is connected to a data output unit (inverter, data logger, etc.) via its data interface (RS232, RS485 or Ethernet) it is purely an information output unit. It displays the data received via the data interface in readable digits. For the accuracy of information displayed, however, the data output unit is responsible. For problems or faulty display the data output unit has to be checked and to observe its operating instructions.
For problems or damages which are caused by changes of the data output unit (p. e. modified protocol structure, or modified product characteristics) no liability is assumed.
These operating instructions do not replace the operating instructions of the data output unit.
BAL XC610 1.12 5/13
3 Important start-up instructions
During the commissioning of the display you need the following facilities for configuration:
1. PC with the software Siebert SafetyDisplayConfigurator
2. A suitable cable depending on the type of display
With displays of the type ...-01 the configuration is done via the serial interface (RS232) of the display. For configuration via RS232 you need to have ready the following items:
A cross-type cable for the RS232 interface between the PC and the display.  If your PC does not have such an interface, you need an USB on RS232 converter. Siebert offers
such a converter, together with the matching ready-made cable, as accessories.
With displays of the type ...-05 with Ethernet interface the configuration is done via the Ethernet. Please have ready the following items:
A cross-type Ethernet cable if you connect the PC for configuration directly with the display.  A patch cable, if you connect the PC for configuration over a switch or router with the display.
BAL XC610 1.12 6/13
Order code
Interfaces
XC610-xxx-x-01
Serial (RS232) (screw-type terminals)
XC610-xxx-x-05
Ethernet (RJ45)
CAUTION!
Make sure that the glass pane is not damaged or, if the display is already mounted on the wall it doesn’t fall down.
4 Product description
The following figure shows the display in working condition.
The scope of information consists of the following characteristic values which you assign to the various fields according to the specific front foil during the first start-up.
Accident-free days  Number of accidents  Accident-free days record  Workdays lost  Custom field 1  Custom field 2
For each characteristic you can enter a fixed number. Alternatively, you can activated the automatic function to ensure that the field is counted by one further at midnight.
The displays of the XC610 series are differed in the following interface versions:
The configuration and the modification of the values is effected by the means of the Windows program ‘SafetyDisplayConfigurator’ included in delivery.
For installation and connection of the data source you must open the display. Thereto loosen the four setscrews on the sides at the fastening elements with the included Allen key.
Then the glass pane can be lifted together with the fastening elements.
In the following chapters the necessary steps for installation and start-up are described in detail.
BAL XC610 1.12 7/13
CAUTION!
If the wall surface is uneven the housing can be distored and damaged when mounting
5 Installation
Requirements to the installation site
The display is designed for wall mounting. The wall surface has to be plane and free of irregularities. The wall must have a sufficient capacity.
Installation material
A parts kid with screws and dowels is included in delivery.
Disassembly of the fastening elements
On delivery the fastening elements are mounted on the front glass. Loosen the setscrews with the supplied Allen key and remove the fastening elements. Pay particular
attention to the plastic panes which serve to protect the glass panels.
Mounting the unit
The lines for data and power supply are fed through the guide holes in the bottom of the housing or at the bottom edge of the device.
Mount the unit using the mounting holes with suitable screws and dowels on the wall. Thereby the mounts for the front panel are screwed as shown below. Make sure that the setscrews face outward because otherwise the subsequent fixing of the glass panel is no longer possible.
BAL XC610 1.12 8/13
Power supply connection
After mounting the device on the wall you connect the line for the power supply. Therefore there is a jack on the printed circuit board. Once the power supply unit is plugged into the 230 V outlet, the display should light up.
When first powered on numbers appear on all digits. Depending on the unit version, during later power-up – after implementing of the configuration – the decimal points light up.
BAL XC610 1.12 9/13
6 Connecting the configuration interface
Configuration via serial interface (RS232)
You need the serial interface for configuration during first start-up and for changing the figures shown, p. e. to update the display after an accident.
The connection of the counter is at the designated RS232 terminal, see figure. As connecting cable type J-Y(St)-Y, 2 x 0,6 mm² or similar is used. The maximum length is 10 meters. If your PC does not have a 9-pin sub-D connector, please use a matching USB adapter. You can get
this as an accessory from Siebert. For normal operation of the display the serial connection is not needed.
Configuration via Ethernet
Devices with the ending number -05 are intended for use in an Ethernet network. The connection to a network is limited to plug in the network connector.
If you connect the device to the network via a switch or a hub, then you need an Ethernet patch cable CAT5 or higher.
If you connect the device directly to the remote station, e.g. with a laptop for configuration or with the inverter/data logger, you need a cross cable CAT5 or higher.
All other settings (network addresses, protocols, etc.) will be set with the SafetyDisplayConfigurator.
BAL XC610 1.12 10/13
7 Start-up and configuration
Configuration of the display
For configuration of the display you need a PC. The necessary steps required for configuration are described in detail in the documentation of the program SafetyDisplayConfigurator.
Start-up and test
Expediently perform a functional test before you close the device permanently.
After you successfully completed the configuration the PC is no longer needed.
Controls
With the button on the printed circuit board the system can be reset to its basic configuration. Turn off the power supply of the display and keep the button pressed while the power supply is turned back on.
On the printed circuit board there is an LED that flashes quickly after starting. After a few minutes the LED turns off.
BAL XC610 1.12 11/13
Series XC610
Dimensions (W x H x D)
420 x 297 x 26 mm
LED display digit height
25 mm
Power supply
100…240 V AC, 50/60 Hz
Power consumption
25 W max.
Protection type
IP40
Weight
approx. 2 kg
Operating temperature
0…40 °C
Storage temperature
-25…85 °C
holes for wall mounting 4,5
Technicshe
8 Technical data
The following figures show the housing dimensions and the holes for wall mounting.
BAL XC610 1.12 12/13
9 Service and Support
If you have any questions or want to take advantages of our services, please contact one of the following addresses:
Germany Siebert Industrieelektronik GmbH
Siebertstrasse, D-66571 Eppelborn Phone +49 (0)6806 980-0 Fax +49 (0)6806 980-999 info.de@siebert-solar.com
France Siebert France Sarl
4 rue de l’Abbé Louis Verdet, F-57200 Sarreguemines BP 90 334, F-57203 Sarreguemines Cédex Phone +33 (0)3 87 98 63 68 Fax +33 (0)3 87 98 63 94 info.fr@siebert-solar.com
Italy Siebert Italia Srl
Via Galileo Galilei 2A, I-39100 Bolzano (BZ) Phone +39 (0)471 053753 Fax +39 (0)471 053754 info.it@siebert-group.com
The Netherlands Siebert Nederland B.V.
Jadedreef 26, NL-7828 BH Emmen Phone +31 (0)591-633444 Fax +31 (0)591-633125 info.nl@siebert-solar.com
Austria Siebert Österreich GmbH
Mooslackengasse 17, A-1190 Wien Phone +43 (0)1 890 63 86-0 Fax +43 (0)1 890 63 86-99 info.at@siebert-solar.com
Switzerland Siebert AG
Bützbergstrasse 2, Postfach 91, CH-4912 Aarwangen Phone +41 (0)62 922 20 43 (German) Phone +41 (0)62 922 20 44 (French) Fax +41 (0)62 922 33 37 info.ch@siebert-solar.com
Other countries Please find the addresses as follows:
www.siebert-solar.com
So that we can help you quickly and efficiently please have the following information ready on demand:
1. Information on the type plate, in particular type and serial number
2. Detailed description of the problem and the circumstances
3. Telephone and fax number and email address under which you can be contracted for queries
BAL XC610 1.12 13/13