Sick DFS20A-A2P1D065536 Data Sheet

Product data sheet
DFS20A-A2P1D065536
DFS2x
INCREMENTAL ENCODERS
A
B
C
D
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
DFS20A-A2P1D065536 | DFS2x
INCREMENTAL ENCODERS
Ordering information
Type Part no.
DFS20A-A2P1D065536 1073247
Other models and accessories www.sick.com/DFS2x
Illustration may differ
Detailed technical data
Performance
Measuring step
Measuring step deviation
Error limits
Initialization time
1)
Valid positional data can be read once this time has elapsed.
Interfaces
Communication interface
Communication Interface detail
Factory setting
Programmable/configurable
Electrical data
Connection type
Power consumption
Supply voltage
Load current
Output frequency
Reference signal, number
Reference signal, position
Code sequence
Reverse polarity protection
Short-circuit protection of the outputs
±90° electric/pulses per revolution
±0.002° pulses > 10,000
±0.03°
1)
40ms
Incremental
TTL
Factory setting: output level TTL
Male connector, MS, 10-pin, radial
0.7W (without load)
4.75... 30V
30mA
820kHz
1
180°, electric, gated with A
Clockwise
1)
1)
Short-circuit opposite to another channel or GND permissable for maximum 30s.
2)
This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of com-
ponents, average ambient temperature 40°C, frequency of use 8760h/a. All electronic failures are considered hazardous. For more information, see document no.
8015532.
2 ENCODERS | SICK Product data sheet | 2020-05-26 18:06:42
Subject to change without notice
DFS20A-A2P1D065536 | DFS2x
INCREMENTAL ENCODERS
MTTFd: mean time to dangerous failure
1)
Short-circuit opposite to another channel or GND permissable for maximum 30s.
2)
This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of com-
ponents, average ambient temperature 40°C, frequency of use 8760h/a. All electronic failures are considered hazardous. For more information, see document no.
8015532.
330years (ENISO13849-1)
2)
Mechanical data
Mechanical design
Shaft diameter
Shaft length
Weight
Shaftmaterial
Flange material
Housing material
Start up torque
Operating torque
Permissible shaft loading radial/axial
Moment of inertia of the rotor
Bearing lifetime
Solid shaft, Square flange
3/8"
16mm
+0.4kg
Stainless steel 1,4305
Aluminum
Aluminum
0.5Ncm (+20°C)
0.3Ncm (+20°C)
40N (axial) 80N (radial)
15gcm²
3.6x 109revolutions
1)
1)
Relates to encoders with male connector outlet MS.
Ambient data
EMC
Enclosure rating
Permissible relative humidity
Operating temperature range
Storage temperature range
Resistance to shocks
Resistance to vibration
1)
With mating connector fitted.
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
According to EN61000-6-2 and EN61000-6-3
IP65, shaft side (according to IEC60529) IP67, housing side, male connector connection (according to IEC60529)
90% (Condensation not permitted)
–30°C... +85°C
–40°C... +100°C, without package
100g, 11ms (according to EN60068-2-27)
30g, 10Hz... 2,000Hz (according to EN60068-2-6)
27270501
27270501
27270590
27270590
27270501
27270501
27270501
27270501
EC001486
EC001486
41112113
1)
2020-05-26 18:06:42 | Product data sheet
Subject to change without notice
ENCODERS | SICK 3
Loading...
+ 5 hidden pages