SICK CLV63 Series,CLV64 Series,CLV62 Series,CLV620,CLV632,CLV640,CLV631,CLV630 Technical Information

T E C H N I C A L I N F O R M A T I O N

CLV62x, CLV63x and CLV64x with IP69K Protec‐ tive Housing
Bar Code Scanners
Described product
CLV62x, CLV63x and CLV64x in IP69K protective housing
Manufacturer
SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐ tion, abridgment or translation of this document is prohibited without the express writ‐ ten permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2
T EC H NI C AL IN F OR M AT I ON | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
Subject to change without notice

Contents

CONTENTS
1 About this document........................................................................ 4
1.1 Information on the Technical Information............................................... 4
1.2 Explanation of symbols............................................................................ 4
2 Safety information............................................................................ 6
2.1 Intended use............................................................................................. 6
2.2 Improper use............................................................................................. 6
2.3 Hazard warnings and operational safety................................................. 6
2.3.1 Laser radiation......................................................................... 6
3 Product description........................................................................... 10
3.1 Product ID.................................................................................................. 10
3.1.1 Type label................................................................................. 10
3.2 Design........................................................................................................ 11
3.3 Scope of delivery....................................................................................... 13
3.4 Differences between devices in IP65 standard housing and devices
in IP69K protective housing..................................................................... 14
3.5 Reading fields........................................................................................... 15
4 Transport and storage....................................................................... 18
4.1 Bar code scanners CLV62x, CLV63x and CLV64x with IP69K protec‐
tive housing............................................................................................... 18
5 Mounting............................................................................................. 19
5.1 Overview of mounting procedure............................................................. 19
5.2 Mounting requirements............................................................................ 19
5.3 Mounting options...................................................................................... 19
5.4 Mounting the protective double bushing on the protective housing..... 20
5.4.1 Assembly with use of the Ethernet connection..................... 20
5.4.2 Assembly without use of the Ethernet connection................ 22
6 Electrical installation........................................................................ 24
6.1 Safety......................................................................................................... 24
6.1.1 Notes on electrical installation............................................... 24
6.2 Prerequisites for safe operation of the device in a system.................... 25
6.3 Pin assignment of the connections......................................................... 25
7 Technical data.................................................................................... 27
7.1 Bar code scanner CLV62x in IP69K protective housing......................... 27
7.2 Bar code scanner CLV63x in IP69K protective housing......................... 29
7.3 Bar code scanner CLV64x in IP69K protective housing......................... 31
8 Accessories........................................................................................ 34
8.1 Brackets.................................................................................................... 34
8.2 Cables........................................................................................................ 34
8021479/0000/2018-03-12 | SICK T E C HN I CA L I N FO R MA T IO N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
Subject to change without notice
3

1 ABOUT THIS DOCUMENT

1 About this document

1.1 Information on the Technical Information

This Technical Information supplements the respective operating instructions and describes mounting and electrical installation of CLV62x, CLV63x and CLV64x bar code scanners which are equipped with an IP69K protective housing.
The operating instructions for the individual product families can be downloaded online from the respective product page on the Internet.
Table 1: Operating instructions for the CLV62x, CLV63x and CLV64x bar code scanners
Device Material number
Operating instructions German
CLV62x 8011964 8011965 8019585 www.sick.com/
CLV63x 8019587 8019588 8019589 www.sick.com/
CLV64x 8019587 8019588 8019589 www.sick.com/
Material number Operating instructions English
Material number Operating instructions French
Product page
CLV62x
CLV63x
CLV64x
This Technical Information contains the device-specific information on the device, mounting and electrical connection. See the operating instructions of the respective product family for more information.
Adherence to all the specified safety notes, warnings and guidelines in this Technical Information and in the corresponding operating instructions is a prerequisite for work‐ ing safely.
This Technical Information is intended to be used by qualified personnel and electrical specialists.
NOTE
Carefully read this Technical Information and the operating instructions of the bar code scanner before carrying out any work with the device.

1.2 Explanation of symbols

Warnings and important information in this document are labeled with symbols. The warnings are introduced by signal words that indicate the extent of the danger. These warnings must be observed at all times and care must be taken to avoid accidents, per‐ sonal injury, and material damage.
DANGER
… indicates a situation of imminent danger, which will lead to a fatality or serious injuries if not prevented.
WARNING
… indicates a potentially dangerous situation, which may lead to a fatality or serious injuries if not prevented.
CAUTION
… indicates a potentially dangerous situation, which may lead to minor/slight injuries if not prevented.
4
T EC H NI C AL IN F OR M AT I ON | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
Subject to change without notice
ABOUT THIS DOCUMENT 1
NOTICE
… indicates a potentially harmful situation, which may lead to material damage if not prevented.
NOTE
… highlights useful tips and recommendations as well as information for efficient and trouble-free operation.
8021479/0000/2018-03-12 | SICK T E C HN I CA L I N FO R MA T IO N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
Subject to change without notice
5

2 SAFETY INFORMATION

2 Safety information

2.1 Intended use

The device consists of a bar code scanner of the product family CLV62x, CLV63x or CLV64x in the Ethernet version with a protective housing with enclosure rating IP69K.
The protective housing comprises two parts, the bar code scanner that is permanently installed in the protective housing at the factory and the supplied protective double bushing including sealing materials for the two electrical connections.
The device is protected against water from high-pressure or steam cleaners and against dust subject to use of the corresponding cables and correct mounting. For the specifi‐ cation, see "Technical data", page 27
NOTICE
The following requirements must be met in order to achieve the IP69K enclosure rating:
Use only the connection cables specified by SICK.
Seal the two cable outlets at the protective double bushing with the corresponding
O-rings.
The O-rings are included in the device scope of delivery and are matched to the outer diameters of the plug connectors.
The device is an intelligent, opto-electronic SICK ID sensor and is used for automated, fixed identification and decoding of bar codes on moving or stationary objects. The device transmits the data content of the decoded bar codes to a higher-level control (PLC) for coordinating further processing.
SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
2.2

Improper use

The protective housing of the factory-installed bar code scanner must not be opened.
The device must not be used in explosion-hazardous areas.
The device does not constitute a safety-relevant device according to the EC Machinery Directive (2006/42/EC).
Any other use that is not described as intended use is prohibited.
Any use of mounting accessories not specifically approved by SICK AG is at your own risk.

2.3 Hazard warnings and operational safety

To reduce health risks and to avoid dangerous situations, observe the safety notes and warnings set out in the following chapters of these operating instructions.

2.3.1 Laser radiation

6
T EC H NI C AL IN F OR M AT I ON | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
The devices work with a red light laser diode in the wavelength 655 nm. They corre‐ spond to laser class 2.
Subject to change without notice
1 2
3 3
SAFETY INFORMATION 2
CAUTION Optical radiation: Laser class 2
The human eye is not at risk when briefly exposed to the radiation for up to 0.25 sec‐ onds. Exposure to the laser beam for longer periods of time may cause damage to the retina. The laser radiation is harmless to human skin.
Do not look into the laser beam intentionally.
Never point the laser beam at people's eyes.
If it is not possible to avoid looking directly into the laser beam, e.g., during com‐ missioning and maintenance work, suitable eye protection must be worn.
Avoid laser beam reflections caused by reflective surfaces. Be particularly careful during mounting and alignment work.
Do not open the housing. Opening the housing may increase the level of risk.
Current national regulations regarding laser protection must be observed.
It is not possible to entirely rule out temporary disorienting optical effects, particularly in conditions of dim lighting. Disorienting optical effects may come in the form of daz‐ zle, flash blindness, afterimages, photosensitive epilepsy, or impairment of color vision, for example.
Output of laser radiation at the device
The entire reading window is a laser output aperture.
Figure 1: Reading window and output aperture of laser radiation in IP69K protective housing
Bar code scanners CLV62x, CLV63x and CLV64x with front reading window
1
Bar code scanners CLV63x and CLV64x with oscillating mirror and side reading window
2
Reading window and laser output aperture
3
NOTE
No maintenance is required to ensure compliance with Class 2 laser.
8021479/0000/2018-03-12 | SICK T E C HN I CA L I N FO R MA T IO N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
Subject to change without notice
Warning symbol on the device
The laser warning label is lasered onto the protective housing. The type label is attached on the housing side of the connections.
In addition to other information, the type label also contains the laser output data. This data consists of: Laser output power (maximum/average), wavelength or wavelength range, and pulse time duration, see "Type label", page 10.
7
4
1
3
4
3
2
2 SAFETY INFORMATION
Figure 2: Position of type label and laser warning label on the IP69K protective housing
1 2 3 4
Bar code scanners CLV62x, CLV63x and CLV64x with front reading window
Bar code scanners CLV63x and CLV64x with oscillating mirror and side reading window
Position of the type label
Position of the laser warning label
Figure 3: Inhalt des Laserwarnschildes am Gerät
What the laser warning label means: Laser radiation – Never look into the light beam – Laser class 2
NOTE Additional laser warning label
If the laser warning label applied to the protective housing is concealed when the device is installed into a machine or paneling, the laser beam output aperture must be suitably labeled. For this purpose, an additional warning label of the same type must be applied next to the output aperture.
Controlling the laser diode
NOTE
The CLV62x, CLV63x and CLV64x bar code scanners in IP69K protective housing do not have an externally visible visual indicator (LED) for laser diode activity.
When operating properly, the device only switches the laser diode on if there is an object in the reading area, or if a reading is required (cyclic reading operation).
A laser timeout can switch off the laser diode automatically in this type of object trigger control if the pulse has stopped for too long (e.g. the conveyor system has stopped). In this case, the current internal reading interval of the device remains open.
Irrespective of the selected configuration type, the laser timeout can be set as follows:
8
T EC H NI C AL IN F OR M AT I ON | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
Subject to change without notice
SAFETY INFORMATION 2
Using the SOPAS ET configuration software, on the Illumination Control device page
During GSD configuration with the “10_Object Trigger Ctrl” module (PROFINET/
PROFIBUS)
At the default setting, laser timeout is deactivated.
The laser diode is permanently or repeatedly switched on in the following device sta‐ tuses:
In the “Percentage Evaluation” and “Auto Setup” operating modes (only used tem‐ porarily for configuration or diagnosis)
In reading operation in the PSDI types “Auto pulse” (adjustable duty cycle) or “free.”
If timeout is activated, it will have no effect here.
8021479/0000/2018-03-12 | SICK T E C HN I CA L I N FO R MA T IO N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
Subject to change without notice
9
D-79276 Reute Made in Germany
1 2
4
6
3
7
8
ß
9
à
5
CLV631-0831S01 P/N: 1062070 S/N: 1249 0001 DC 18...30V 8.5W Imax=800mA
Pmax=7.0mW P<1.0mW average λ=655nm Pulse duration <80μS
MAC 00:00:00:00:00:00 Manufactured: April 2017

3 PRODUCT DESCRIPTION

3 Product description

3.1 Product ID

3.1.1 Type label

The type label is attached on the housing side with the electrical connections.
Figure 4: Type label on IP69K protective housing (example)
Type designation
1
Part number
2
Serial number
3
Supply voltage and power consumption
4
Maximum current consumption
5
Maximum laser output
6
Average laser output
7
Laser wavelength
8
Laser pulse duration
9
MAC address
ß
Date of manufacture
à
10
T EC H NI C AL IN F OR M AT I ON | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
Subject to change without notice

3.2 Design

50°
70 (2.76)
1
2
30
(1.18)
52.5
(2.07)
71.5 (2.81)
30.4
(1.20)
84 (3.31) 59 (2.32)
12.5
(0.49)
24
(0.94)
3
85 (3.35)
110 (4.33)
44
(1.73)
24
(0.94)
4
4
PRODUCT DESCRIPTION 3
CLV62x in IP69K protective housing, front reading window
Figure 5: CLV62x: design and device dimensions of the IP69K protective housing with front read‐ ing window (dimensions in mm or inch)
Fixing holes, dia. 5.5 mm (4 x)
1
“Ethernet” connection, female connector, M12, 4-pin, D-coded
2
“Power/Serial Data/CAN/I/O” connection, male connector, M12, 17-pin, A-coded
3
Threaded hole, M5 (2 x)
4
Reference point for reading distance (housing edge – object)
5
Light emission position (central position of the deflected laser beam)
6
Protective double bushing for the electrical connections
7
8021479/0000/2018-03-12 | SICK T E C HN I CA L I N FO R MA T IO N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
Subject to change without notice
11
Loading...
+ 25 hidden pages