Product data sheet
CFS50-AEV10X03
CFS50
MOTOR FEEDBACK SYSTEMS ROTARY INCREMENTAL WITH COMMUTATION
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
CFS50-AEV10X03 | CFS50
MOTOR FEEDBACK SYSTEMS ROTARY INCREMENTAL WITH COMMUTATION
Ordering information
Type Part no.
CFS50-AEV10X03 1065229
Other models and accessories www.sick.com/CFS50
Illustration may differ
Detailed technical data
Performance
Number of lines per revolution
Measuring step
Commutation signals
Reference signal, number
Reference signal, position
Operating speed
1)
Number of lines from 1… 1,000and >4,096… 65,536on request.
Interfaces
Communication interface
Electrical data
Connection type
Supply voltage
Power consumption
Maximum output frequency
1)
Without load.
Mechanical data
Shaft version
Flange type / stator coupling
Dimensions
Weight
Moment of inertia of the rotor
Operating speed
Angular acceleration
Operating torque
Start up torque
Permissible movement of the drive element,
static
Permissible movement of the drive element,
dynamic
1,024
90° /number of lines
3pole pairs (See diagram, different commutation on request)
1
90° electric, logically gated with A and B
≤6,000min⁻¹
Incremental
Stranded wire, 15-pin, radial
4.5VDC... 5.5VDC
60mA
≤820kHz
Tapered shaft
Rubber support
See dimensional drawing
0.1kg
10gcm²
12,000min⁻¹
≤200,000rad/s²
0.2Ncm
0.4Ncm
Radial
±0.75mm axial
±0.1mm radial
±0.2mm axial
1)
1)
2 MOTOR FEEDBACK SYSTEMS | SICK Product data sheet | 2020-08-22 08:21:24
Subject to change without notice
CFS50-AEV10X03 | CFS50
MOTOR FEEDBACK SYSTEMS ROTARY INCREMENTAL WITH COMMUTATION
Angular motion perpendicular to the rota-
±0.005mm/mm
tional axis, static
Angular motion perpendicular to the rota-
±0.0025mm/mm
tional axis, dynamic
Life of ball bearings
3.6x 109revolutions
Ambient data
Operating temperature range
Storage temperature range
Relative humidity/condensation
Resistance to shocks
Frequency range of resistance to vibrations
EMC
Enclosure rating
1)
The EMC according to the standards quoted is achieved when the motor feedback system is mounted in an electrically conductive housing, which is connected to
the central earthing point of the motor controller via a cable screen. The GND-(0V) connection of the supply voltage is also grounded here. If other shielding concepts
are used, users must perform their own tests.
–20°C... +115°C
–40°C... +125°C, without package
90%, Condensation not permitted
100g, 10ms (according to EN60068-2-27)
20g, 10Hz... 2,000Hz (according to EN60068-2-6)
According to EN61000-6-2 and EN61000-6-3
IP40 (according to IEC60529)
1)
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ECl@ss 10.0
ECl@ss 11.0
ETIM 5.0
ETIM 6.0
ETIM 7.0
UNSPSC 16.0901
27270501
27270501
27270590
27270590
27270501
27270501
27270501
27270501
27273805
27273901
EC001486
EC001486
EC001486
41112113
2020-08-22 08:21:24 | Product data sheet
Subject to change without notice
MOTOR FEEDBACK SYSTEMS | SICK 3