Siamp Optima 49 Troubleshooting And Assembly Instructions

Vitra S20 Troubleshooting
Sticking or not flushing Passing water
First check that the valve position is as shown above,
the valve should be clear of the cistern wall, if not remove the valve and re-position.
(right).
If the problem persists please contact Siamp Aftersales on 0161 681 2120 or aftersales@siamp.co.uk
No Description Setting Figure
1 Stirrup Position 7 (number 6 will be visible) A
2 Lift Rod Position 5 (4 holes above will be visible) B
3 Overflow Factory set. D will be visible B
4 Residual Water 0 C
5 Short flush cursor 10 D
Fig A.
Stirrup in position 7.
(number 6 will be visible)
Fig B.
Lift Rod in position 5
(4 holes visible above)
Overflow tube pre-cut at D
Fig C.
Residual Water set at 0
Fig D.
Short flush cursor set at 10
Vitra S20 Troubleshooting
Sticking or not flushing
Passing water
a
Button
Short flush
Long flush
b
Optional escutcheon
(not always supplied)
GB
Stirrup
Overflow
Stirrup
catch clip
Short
flush
cursor
j
Valve gasket
Strainer gasket
Pan gasket
m
l
c
Lift rod
k
d
Residual sliding valve
e
i
h
g
Strainer
f
Strainer nut
OPTIMA 49
Ref.: 50 5498 01
ASSEMBLY INSTRUCTIONS
I - PREPARING THE MECHANISM
D
H
Check the position of the stirrup
If the stirrup (m) is correctly positioned on the basis of the below table, proceed to step ➏. Otherwise, carry out all of the following steps:
Unclip the lift rod (c)
Remove the stirrup (m) , by pressing on
the two catch clips (k)
Cut the overflow (l) if necessary according
to the table
Reposition the stirrup in its seat and slide
it to the required position (desired setting notch number visible)
Clip lift rod (c) back into the hole of the
overflow (l) which has the same number as that of the setting notch
Unscrew the strainer nut (f)
Measure the cistern
-H (from the top of the lid to the inside base of the cistern)
-D (diameter of the hole in the lid)
+ ➋ =
Height H of cistern
Diameter D Diameter D of hole in lid of hole 18 to 38 mm in lid and 38 to 45 to 50 mm 44 mm
11 430 to 417 448 to 435
10 416 to 405 434 to 423
9 404 to 393 422 to 411
8 392 to 381 410 to 399
7 380 to 369 398 to 387
6 368 to 357 386 to 375
5 356 to 345 374 to 363
4 344 to 333 362 to 351
3 332 to 321 350 to 339
2 320 to 309 338 to 327
No. of notch visible on lift rod
1 308 to 297 326 to 315
Mini
296 to 282 314 to 300
Stirrup notch Cut on overflow tube 3 C mark visible 2 F mark visible 1 I mark visible Mini L mark visible
Visible stirrup notch
no. 4 = position of lift rod no. 4
II - INSTALLATION
Position the mechanism in the cistern and secure it in place with the nut (f)
Manually screw the flush valve nut (f) until it is in contact with the ceramic. If necessary give an extra quarter turn (maximum) with the appropriate spanner.
NB : Excessive tightening can damage the mechanism and would not be covered by the guarantee.
ASSEMBLING BOWL AND CISTERN
WATER LEVEL MAX 6L - MIN 4.5L PER FLUSH
Fix screws at the bottom
of the cistern (see order of parts below)
Position the latex foam
gasket on the nut (f)
M6x78 screw
Washer
Conical seal
Bottom of cistern
Washer
Hexagon nut
Wall of bowl
Position the cistern on
the bowl and secure it with wing nuts
IV - SETTING WATER LEVELIII -
After having connected your ballcock to the water supply, open the tap and set the level of the long flush using the ballcock (see overleaf).
Note: The max. water level should be 20 mm lower than the overflow tube (l).
Overflow
Max.
water level
20 mm
To adjust the water level of the short flush, slide the cursor along (j). Immerse the cursor of 40 mm.
Note : The closer the cursor is to 18, the more water will be flushed.
Wing nut
V - INSTALLATION OF BUTTON
Once the set-up has been completed, put on the lid
on the cistern
If the hole in the lid (D) is > 38 mm and < 45 mm,
remove the escutcheon (b)
Position the button on the lid and screw until tight.
In some (rare) cases, the residual water level (amount of water remaining after the long flush) must be increased to ensure more efficient cleaning. To do this, move the sliding valve (d) to the left (the more it is open, the more the residual water increases).
Note: Increasing the residual water reduces the volume of water flushed. If necessary, readjust the max. water level using the ballcock.
VI - MAINTENANCE
Changing the valve gasket
After having opened
the cistern, turn the mechanism 90° to separate it from its
Valve gasket
Strainer
strainer
Change the valve
gasket
Reposition the
mechanism, locking it into the strainer
Close the cistern
again.
INSTALLING THE FLOAT VALVE
ROBECO 06 and STANDARD 15EL
Position valve
Fasten with nut
Connect to water supply
Adjust water level with the adjustment screw
(15 EL) or by bending the rod (06)
Adjustment screw
Fiber gasket
Insert rod as far as possible
Manually screw the backnut until it is in contact with the ceramic. If necessary give an extra quarter turn (maximum).
N.B.: Excessive tightening can damage the mechanism and would not be covered by the guarantee.
Ensure tightness of connection to cistern with filter gasket.
Locking nut
COMPACT 99B and HANDY 93B
COMPACT 95L
Position valve
Fasten with nut
Connect to water supply
Adjust water level with the adjustment screw
Adjustment screw
Fiber gasket
Locking nut
WARNINGS:
1 - Do not overtight in any case. 2 - Do not use any sealing paste and/or compound in any
case
3 - Do not use connector handling the internal part of the
inlet valve.
SIAMP will be not responsible in case these warnings are not respected.
MAINTENANCE (95L & 99B)
Adjustment screw
Locking nut
Gasket/filter
Membrane
Filter
Adjustment
screw
Locking nut
Fiber gasket
Membrane