First check that the valve position is as shown above,
the valve should be clear of the cistern wall, if not
remove the valve and re-position.
If the valve position is correct, check the valve settings
are still in the factory set positions detailed in the table
(right).
If the problem persists please contact Siamp Aftersales
on 0161 681 2120 or aftersales@siamp.co.uk
✘
✘
NoDescriptionSettingFigure
1Stirrup Position 7 (number 6 will be visible)A
2Lift RodPosition 5 (4 holes above will be visible)B
3OverflowFactory set. D will be visibleB
4 Residual Water0C
5Short flush cursor10D
✘
Fig A.
Stirrup in position 7.
(number 6 will be visible)
Fig B.
Lift Rod in position 5
(4 holes visible above)
Overflow tube pre-cut at D
Fig C.
Residual Water set at 0
Fig D.
Short flush cursor set at 10
Vitra S20 Troubleshooting
Sticking or not flushing
Passing water
a
Button
Short flush
Long flush
b
Optional escutcheon
(not always supplied)
GB
Stirrup
Overflow
Stirrup
catch clip
Short
flush
cursor
j
Valve gasket
Strainer gasket
Pan gasket
m
l
c
Lift rod
k
d
Residual sliding valve
e
i
h
g
Strainer
f
Strainer nut
OPTIMA 49
Ref.: 50 5498 01
ASSEMBLY INSTRUCTIONS
I - PREPARING THE MECHANISM
D
H
Check the position of the stirrup
If the stirrup (m) is correctly positioned
on the basis of the below table, proceed
to step ➏. Otherwise, carry out all of the
following steps:
Unclip the lift rod (c)
➊
Remove the stirrup (m) , by pressing on
➋
the two catch clips (k)
Cut the overflow (l) if necessary according
➌
to the table
Reposition the stirrup in its seat and slide
➍
it to the required position (desired setting
notch number visible)
Clip lift rod (c) back into the hole of the
➎
overflow (l) which has the same number as
that of the setting notch
Unscrew the strainer nut (f)
➏
Measure the cistern
-H (from the top of the lid to the inside base of the cistern)
-D (diameter of the hole in the lid)
+ ➋ =
➊
➋
➊
➌
➍
Height H of cistern
Diameter D Diameter D
of hole in lid of hole 18 to 38 mm in lid
and 38 to
45 to 50 mm 44 mm
11 430 to 417 448 to 435
10 416 to 405 434 to 423
9 404 to 393 422 to 411
8 392 to 381 410 to 399
7 380 to 369 398 to 387
6 368 to 357 386 to 375
5 356 to 345 374 to 363
4 344 to 333 362 to 351
3 332 to 321 350 to 339
2 320 to 309 338 to 327
No. of notch visible on lift rod
1 308 to 297 326 to 315
Mini
296 to 282 314 to 300
Stirrup notch Cut on overflow tube
3 C mark visible
2 F mark visible
1 I mark visible
Mini L mark visible
➎
Visible stirrup notch
no. 4 = position of lift rod no. 4
II - INSTALLATION
Position the mechanism
in the cistern and secure
it in place with the nut (f)
Manually screw the
flush valve nut (f) until
it is in contact with
the ceramic. If
necessary give an
extra quarter turn
(maximum) with the
appropriate spanner.
NB : Excessive
tightening can damage
the mechanism and
would not be covered by
the guarantee.
ASSEMBLING BOWL AND CISTERN
WATER LEVEL MAX 6L - MIN 4.5L PER FLUSH
Fix screws at the bottom
➊
of the cistern (see order of
parts below)
Position the latex foam
➋
gasket on the nut (f)
M6x78 screw
Washer
Conical seal
Bottom of cistern
Washer
Hexagon nut
Wall of bowl
Position the cistern on
➌
the bowl and secure it
with wing nuts
IV - SETTING WATER LEVELIII -
After having connected your ballcock to the water
supply, open the tap and set the level of the long flush
using the ballcock (see overleaf).
Note: The max. water level should be 20 mm lower
than the overflow tube (l).
Overflow
Max.
water level
20 mm
To adjust the water level of the short flush, slide the
cursor along (j). Immerse the cursor of 40 mm.
Note : The closer the cursor is to 18, the more
water will be flushed.
Wing nut
V - INSTALLATION OF BUTTON
Once the set-up has been completed, put on the lid
➊
on the cistern
If the hole in the lid (D) is > 38 mm and < 45 mm,
➋
remove the escutcheon (b)
Position the button on the lid and screw until tight.
➌
In some (rare) cases, the residual water level
(amount of water remaining after the long flush)
must be increased to ensure more efficient
cleaning. To do this, move the sliding valve (d) to
the left (the more it is open, the more the residual
water increases).
Note: Increasing the residual water reduces the
volume of water flushed. If necessary, readjust the
max. water level using the ballcock.
VI - MAINTENANCE
Changing the valve gasket
After having opened
➊
the cistern, turn the
mechanism 90° to
separate it from its
Valve gasket
Strainer
strainer
Change the valve
➋
gasket
Reposition the
➌
mechanism, locking it
into the strainer
Close the cistern
➍
again.
INSTALLING THE FLOAT VALVE
ROBECO 06 and STANDARD 15EL
Position valve
➊
Fasten with nut
➋
Connect to water supply
➌
Adjust water level with the adjustment screw
➍
(15 EL) or by bending the rod (06)
Adjustment screw
Fiber gasket
Insert rod
as far as
possible
Manually screw the backnut until it is in contact with the
ceramic. If necessary give an extra quarter turn (maximum).
N.B.: Excessive tightening can damage the mechanism and
would not be covered by the guarantee.
Ensure tightness of connection to cistern with filter gasket.
Locking nut
COMPACT 99B and HANDY 93B
COMPACT 95L
Position valve
➊
Fasten with nut
➋
Connect to water supply
➌
Adjust water level with the adjustment screw
➍
Adjustment screw
Fiber gasket
Locking nut
WARNINGS:
1 - Do not overtight in any case.
2 - Do not use any sealing paste and/or compound in any
case
3 - Do not use connector handling the internal part of the
inlet valve.
SIAMP will be not responsible in case these warnings
are not respected.