Siamp STORM 33A, COMPACT 99B Assembly Instructions Manual

SINGLE FLUSH VALVE STORM 33A BOTTOM INLET VALVE COMPACT 99B
ASSEMBLY INSTRUCTIONS
PJH
DESCRIPTION
a
c
d
e
h
i
f
g
b
j
k
m
n
l
o
Tools required (not spplied):
• Slotted screwdriver and adjustable spanner.
FITTINGS SUPPLIED
Advice:
• Before you Start
- Read these instructions carefully.
- Check the pack and make sure you have all the parts on the pack list.
- Remove all packaging from pottery and check for surface damage or defects.
- Prepare a firm working surface (e.g; floor or bench) for cistern assembly, covering work surface with cloth to prevent scratching the glazed faces of the cistern.
• Care & Use
- Wipe clean with a soft damp cloth around the WC suite.
- Never use scourers or abrasives.
• Water connection
- Water connection should be made only with an approved tap connector (not supplied). Preparatory sealing compounds should not be used.
• Maintenance
Your new product is designed to have a long life span, however under certain conditions e.g. hard water, «water hammer», excessive water pressure or installation debris in the water pipe, it is possible that the life span of the diaphragm washer will be reduced. To ensure long lasting customer satisfaction, a spare diaphragm washer is included in this pack.
Pushbutton (1) Valve body (1) Rubber Washer (1) Fixing nut (1) Sealing Gasket (1) Inlet valve (1) Inlet Rubber Washer (1) Backnut (1)
a
b
c
d
e
f
g
h
PARTS SUPPLIED
Spanner (1)
Bolt (2)
Sealing washer (2)
Washer (4)
Nut (2)
Butterfly nut (2)
Spare Diaphragm Washer (1)
i
j
k
l
m
n
o
I - ASSEMBLING THE INLET VALVE
II - ASSEMBLING THE OUTLET VALVE
Place Inlet valve (F) through Inlet hole with inlet Rubber Washer (G) inside the cistern.
Secure with backnut (H) but ensure float moves freely up and down valve body.
NB : Manually screw the backnut until it is in contact with the ceramic. If necessary give an extra quarter turn (maximum). Excessive tightening can damage the mechanism and would not be covered by the guarantee.
Slide bolt (J) through washer (K) and sealing washer (L) then place through cistern and secure with washer (K) and nut (M) using adjustable spanner.
Assemble the valve body (B) through cistern with rubber washer (C) on inside of the cistern.
Secure Fixing nut (D).
NB : Manually screw the flush valve nut until it is in contact with the ceramic. If necessary give an extra quarter turn (maximum) with the spanner (I).
Excessive tightening can damage the mechanism and would not be covered by the guarantee.
1
2
3
1
2
An approved double check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting.
Try the lid on the cistern to see if the valve is too high or too low :
To adjust :
Remove clips (x2) (1)
Unclip rod (2)
Adjust to correct height
Replace clips (x2) (1)
Push down at point (3) and clip rod in at (2).
III - ASSEMBLING CISTERN TO PAN
Slide sealing gasket (E) over fixing nut
Slide cistern onto W.C. backplate by locating screws through W.C.
Secure using butterfly nut (N).
IV - ADJUSTMENT OF VALVE HEIGHT
4
5
Butterfly nut (N)
Cistern
Pan
(3)
(2)
(1)
1
2
3
1
2
3
V - SETTING WATER LEVEL
Connect the supply to the inlet valve.
N.B. : Make connecting tightness with filter
seal.
WARNINGS:
1 - Do not overtight in any case. 2 - Do not use any sealing paste and/or
compound in any case
3 - Do not use connector handling the
internal part of the inlet valve.
SIAMP will be not responsible in case these warnings are not respected.
Allow cistern to fill and by screwing the grey bolt slide the float to set water level to waterline.
Ensure movement of float is not restricted.
VI - ASSEMBLING THE BUTTON
Screw the button down, without pushing the central part.
1
2
3
1
THE FINISHED ASSEMBLY INSIDE THE CISTERN
MAINTENANCE
Servicing the valve
To access the valve, unscrew the assembly as shown.
(2)
(1)
For further enquiries
Contact Customer Services PJH on 0161 703 3360
1
To change the diaphragm washer inside the inlet valve
Turn off the water supply to the inlet valve.
Unscrew the knurled nut at the top of the inlet valve
Remove the black rubber diaphragm washer
Insert the replacement washer
Screw the nut back onto the inlet valve, ensuring that the lift arm is holding the float valve correctly
Turn the water supply back on
1
2
3
4
5
6
3
4
4, quai Antoine 1er - BP 219 - MC 98007 MONACO Cedex
Tél. 00 377 93 15 53 75 - Fax : 00 377 92 05 71 04
E-mail: contact@siamp.com
Site Internet : http//: www.siamp.com
Réf. 50 5292 00
SINGLE FLUSH VALVE STORM 33A BOTTOM INLET VALVE COMPACT 99B
Loading...