Shyam Telecom DB6M33SA Users Manual

5920 003
0 200 September 2010
L
imited
.
Next Generation Sig n a l Enhancem e nt
RF / DB6M Series
OOPPEERRAATTIIOONN && IINNSSTTAALLLLAATTIIOONN MMAANNUUAALL
6 Sub-Band Repeater for Outdoor Applications
(FCC ID: S3CDB6M33SA and IC:5751A-DB6M33SA
for AWS and 700 LTE Upper C Sub-Bands only)
DDBB66MM (
(Dual Band)
The information contained herein is proprietary to Shyam Telecom Limited. Unauthorized access, copy and replication are prohibited. This document must
not be copied in whole or part by any means or it shall not be disclosed or divulged to any third Party without the prior written consent of
PROPRIETARY INFORMATION
Shyam Telecom
. Page All Rights Reserved Shyam Telecom Limited 1/43
CONTENTS
1. Document History.........................................................................................4
2. Disclaimer...................................................................................................... 5
3. Safety Instructions and Warnings ...............................................................6
3.1. Personnel Safety....................................................................................6
3.2. Equipment Safety...................................................................................6
3.3. Electrostatic Sensitivity..........................................................................6
4. Intr oduction...................................................................................................7
4.1. Purpose .................................................................................................7
4.2. Scope.....................................................................................................7
4.3. Definitions..............................................................................................7
4.4. References ............................................................................................8
Next Generation Sig n a l Enhancem e nt
4.5. General..................................................................................................9
5. Functional Description of DB6M Dual Band Repeater............................... 9
5.1. General Description...............................................................................9
6. To Get started-Basic Software Control Of the system.............................11
6.1. General................................................................................................11
6.2. Terminal Set-up ...................................................................................12
6.3. Block Schematic Description ...............................................................26
7. DB6M Repeater Specifications ..................................................................28
7.1. Electrical Specifications-RF...................................................................1
7.2. Electrical Specification Power Requirement ..........................................1
7.3. External Electrical Interface.................................................................29
7.4. Mechanical Specification .....................................................................29
7.5. Environmental Specification.................................................................29
7.6 Contents of Delivery............................................................................30
8. Installation................................................................................................... 31
8.1. Preparation Sheet- Pre Installation......................................................31
8.2. Engineering Consideration...................................................................32
8.3. Installation Tools..................................................................................34
8.4. Installation Procedure..........................................................................34
8.5. Repeater Gain Settings........................................................................35
8.6. Commissioning ....................................................................................35
8.7. Dos & Don’t Dos ..................................................................................36
. Page All Rights Reserved Shyam Telecom Limited 2/43
Next Generation Sig n a l Enhancem e nt
8.8. Checklist – Post Installation.................................................................37
9. Trouble Shooting........................................................................................40
10. System Maintenance.................................................................................41
10.1. General..............................................................................................41
10.2. Preventive Maintenance ....................................................................41
11. Shut Down Mechanisms……………………………………………………42
. Page All Rights Reserved Shyam Telecom Limited 3/43
Next Generation Sig n a l Enhancem e nt
1. Document History
Document Number
5920 0030 200
Revision Revised Section Date
Document Name
DB6M Dual Band Repeater
Date Compiled
by
September 2010
Inderjit Ramvir
Approved
by
Singh
Revision
. Page All Rights Reserved Shyam Telecom Limited 4/43
Next Generation Sig n a l Enhancem e nt
Intentionally Left Blank
2. Disclaimer
Every attempt has been made to make this material complete, accu rate, and up-to-date. Users are cautioned, however, that Shyam Telecom Limited
reserves the right to make changes without notice and shall not be responsible for any damages inc luding consequen tial, caused by reliance of the contents presented, including, but not limited to, typographical, arithmetical, or listing errors.
Product name(s) referenced in this document may be trademarks or registered trademarks of their respective companies, and are hereby acknowledged.
In areas with unstable power grids (mains) all repeaters must be installed with a voltage regulator ensuring a constant voltage level at the repeater power input. A maxi mum voltage d eviation should remain within the input ran ge to the repeaters for warranty purposes.
All antennas must be installed with lightening protection. Damage to inter nal modules, as a result of lightening is not covered by the warranty.
All specifications are subject to change without prior notice.
. Page All Rights Reserved Shyam Telecom Limited 5/43
3. Safety Inst r uctions and Warnings
3.1. Personnel Safety
Before installing or replacing any equipment, the entire manual should be read and understood. The user ne eds to supply the appropriate AC power to the Repeater. Inc orrect AC p ower settings can damage the re pea ter and may cause injury to the user.
Throughout this manual, there are "Caution" warnings, "Caution" calls attention to a procedure or prac tice, which, if ignored, may result in injury or damage to the system or system component or even the user. Do not perform any procedure preceded by a "Caution" until the described conditions are fully understood and met.
3.2. Equipment Safety
When installing, replacing or using this product, observe all safety precautions during handling and operation. Failure to comply with the following general s afety precautions and with spec ific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product. Shyam Telecom Limited assumes no liability for the customer's failure to comply with these precautions. This entire manual should be read and understood before operating or maintaining the repeater system.
It calls attent ion to a procedure or practice whi ch, if not followed, may res ult in personal injury, damage to the system or damage to individual components. Do not perform any procedure preceded by a
CAUTION until described conditions are fully understood and met.
CAUTION
3.3. Electrostatic Sensitivity
ESD = ELECTROSTATIC DISCHARGE SENSI TIVE DEVI CE
Observe electrostatic precaut ionary procedures .
CAUTION
Next Generation Sig n a l Enhancem e nt
. Page All Rights Reserved Shyam Telecom Limited 6/43
Next Generation Sig n a l Enhancem e nt
Semiconductor transmitters and receivers provide highly reliable performance
when operated in conformity with the intentions of their design. semiconductor may be damaged by an electrostatic charge inadvertently imposed by careless handling.
However, a
Static elec tricity can be conducted to the semico nductor chip fro m the centre
pin of the unpacking and otherwise handling the
procedures includin g the use of grounded wrist straps, grounded workbench surfaces, and grounded floor mats.
RF input connector, and through the AC connector pins. When
Repeater, follow ESD precautionary
The RF repeater mentioned is tested thoroughly for maximum composite power.
There is provision of control) which limits the output power in DL path and in UL path beyond the specified limit.
(
CF in UL 781 MHz & CF in DL 751 MHz) and AWS band 10 MHz sub-band (
It operates in LTS 700 band – upper C sub-band of 10 MHz BW
ALC / APC (automatic level control / automatic power
UL 1710-1755MHz, DL 2110-2155MHz). Donor antenna and server antenna
must be fixed on permanent structure with enough isolation between donor and server antenna to avoid any possible oscillations.
4. Introduction
4.1. Purpose
The purpose of this document is to describe the electrical and mechanical specifications, operation and maintenance of the
DB6M Dual Band
Repeater.
4.2. Scope
This docu ment is t he product description of the Shyam
DB6M Dual Band
Repeater for o u tdoor application.
4.3. Definitions
AGC ALC APC BCCH BTS BSEL
Automatic Gain Control Automatic Level Control Automatic Power Control Broadcast Control Channel Base Transceiver Station Band Selective
. Page All Rights Reserved Shyam Telecom Limited 7/43
Next Generation Sig n a l Enhancem e nt
CDMA CMC CMB CSEL DCS DL
EGSM ETSI GSM GUI LAC LED LNA LO MS MSC NMS PCN PCS PSU RF RMS
RSSI RTC SMS TACS TDMA VFD UL (Uplink)
4.4. References
[1] ETS 300 086
Radio Equipment and Systems Land mobile service Technical characteristics and test conditions for radio equ ipment with an internal or external RF connector intended primarily for analogue speech.
[2] ETS 300 609-4
Digital cellular telecommunications system (phase 2): Base Station
Coded Division Multiple Access Configuration & Monitoring Console software Combiner Unit Channel Selective Digital Communication System Downlink signal (from base station via repeater to
mobile station)
Extended Global System for Mobile Communication European Telecommunications Standard In stitute Global System for Mobile communicati on Graphics User Interface Location Area Code of the BTS site Light Emitting Diode Low Noise Amplifier Local Oscillator Mobile Station Mobile Switching Center Network Management System Personal Communication Network Personal Communication System Power Supply Unit Radio Frequency Repeater Management System/Remote Monitoring System Received Signal Strength Indication Real Time Clock Short Message Service Total Access Communication System Time Division Multiple Access Visual Florescent Display Uplink signal direction (from mobile station via
repeater to base station)
. Page All Rights Reserved Shyam Telecom Limited 8/43
Systems (BSS) equipment specification: Part 4: Repeaters.
[3] ETS 300 342-3
Radio Equipment and Systems (RES); Electro-Magnetic Compatibility (EMC) for European Digital Cellular Telecommunications Systems. Base Station Radio and ancillary equipment and Repeaters meeting phase 2 GSM requirements.
4.5. General
Mobile Communications Systems are pla nned as cellu lar systems and each
cell of the base station is required to provide geographical area as per defined propagation propert ies, even using high rad iated antenna systems, there are zones within the coverage area where the
signal strength from base station remains inadequate for establishing the desired connectivity to mobile users.
RF power levels. Due to the RF
RF coverage over a certain
RF powers or complicated
Repeaters tradi tionally are deplo yed in the Mobile Communication Network
to fill in the topologies such as mountains, valleys, dense foliage, high rising urban
landscapes and other man-made structures. station also adversely affects the
repeaters as a means to extend base stati on coverage so as to reduce the number of base stations and thereby accelerate network availability.
“Dead Zones caused by blocking of signals by geographic
The distance from the base
RF signal strength. The user views
Repeater systems ar e i nstalled a fter meticu lous plan ning between BTSs and
the mobile users to provide systems are available for different applications and ultimate choice shall depend on some of the factors mentioned below:
Area to be provided with coverage.
Indoor/outdoor coverage.
Availability of BTSs in the vicinity.
Antenna isolation to be achieved.
RF coverage in the s hadowed r eg ions. Repeater
5. Functional Description of DB6M Dual Band Repeater
5.1. General Description
The
DB6M dual band modular Repeater System is designed to provide
outdoor covera ge and can han dle signals in up to six sub bands maximum
3+3 configuration or as per requirement in two of the service bands,
with used around the selective amplification in the pre-set frequency bands.
operating service frequency bands are given below:
SNo Service Band
World by various service operators. It provides highly
DL Frequency (MHz) UL Frequency (MHz)
Next Generation Sig n a l Enhancem e nt
RF
The details of
. Page All Rights Reserved Shyam Telecom Limited 9/43
Next Generation Sig n a l Enhancem e nt
S.No. Service Band DL Frequency (MHz) UL Frequency (MHz)
1. SMR 800 851-866 806-821
2. Cellular 869-894 824-849
3. SMR 900 935-941 896-902
4. EGSM 925-960 880-915
5. GSM 900 935-960 890-915
6. DCS 1805-1880 1710-1785
7. PCS 1930-1990 1850-1910
8. UMTS 2110-2170 1920-1980
9. AWS 2110 – 2155 1710 - 1 755
10. LTE 700 Upper C, A and B sub-bands are avai lable
The Customer is requested to refer to the sticker on the repeater unit giving
the details of frequency bands set equipped in the repeater.
**Only sub bands of AWS and LTE700 Upper C are for FCC and IC approval under FCC ID:
S3CDB6M33SA and IC:5751A-DB6M33SA.
& the bandwidths of different sub bands
Models: OD6R2-Equipp ed with 2 sub bands
OD6R3-Equipped with 3 sub bands OD6R4-Equipped with 4 sub bands OD6R5-Equipped with 5 sub bands OD6R6-Equipped with 6 sub bands
The DB6M repeater is designed to provide optimal coverage, the
area covered shall primarily de pend on structures in the area (high rise buildings), the geograph ical topologies and availability of reflecting surfaces.
The ultimate performance & coverage shall depend on the
obstructions blocking between the Server antenna of
The repeater is specifically designed for the Operators who are
allocated frequency spectrum in different service bands and non­contiguous sub bands are specified.
The repeater adopts d uplex mode and bi-directional amplification for
/ absorbing of the RF signals by various ob jects
RF repeater and the mobile users.
RF power radiated, manmade
UL & DL signals between the base station and mobile users.
. Page All Rights Reserved Shyam Telecom Limited 10/43
It receives s ignals from the BTS thr ough a DONOR ant enna (highly
directional outdoor antenna after amplificati on through the
DL.
In the UL, the signals from the mobile users are picked up by
SERVER antenna and retransmitted to the
The repeater finds applications in tunnels, highways, large size
airports, and open market areas etc. where traffic requirement is high.
The system can be incor porated with optional Remote Management
) and distributes the signals to mobile users
SERVER antenna(s) of directional type in
BTS after amplification.
System (RMS) which can be used for configuration and monitoring
the status of the link. It helps not only sp eedy maintenance but remote configura tion also through wireless modem.
The repeater consists of the following modules/units:
LNA
Converter modules
Power amplifiers
Power supply module
Quad-plexer for segregating bands with DL/UL directions
Supervisory module
Modem with rechargeable battery & antenna (Optional)
External modem with power adapter & antenna along with software CD for RMS (optional) application
A metallic case houses the repeater. Arrangement is made for heat
dissipation especially for amplifiers, which generate more heat. choice of suitable metal as the case material gives a lightweight design with good heat conduction and waterproof protection.
conforms to
IP65 (NEMA 5) standards.
6. To Get started-Basic Software Control Of the system
6.1. General
The system is eq uipped with a s u perv is ory mod ule tha t allows the monitoring
and control of various parameters such as temperature, status of door and alarm conditions etc.
RF power, attenuation,
The communication interface between the local terminal and the control
module can be set up using the software monitoring.
required.
(CMC), which is an easy to use GUI for simple control and
It enables monitoring of parameters & subsequent ad justment if
Configuration & Monitoring Console
Next Generation Sig n a l Enhancem e nt
The
The housing
. Page All Rights Reserved Shyam Telecom Limited 11/43
This function can be perfor med either using a terminal (PC/laptop) locally, or
through remote login using the wireless modem repeater.
USB port is provisioned in the equipment for connecting
PC/laptop.
6.2. Terminal Set-up
The system is delivered with software loaded in order to perform
configuration as per requirement. Configuration o f parameters can be carried out local ly with the help of laptop /
PC connected to the repeater by means of local USB serial interface or
remo tely v ia wire less mod em laptop/ supplied
PC should be loaded with the CMC software available on the
CD along with the USB driver.
I) Login Repeater (Figure 3)
After runni ng the Configuration & Monitoring Console (CMC), use r needs
to login the repeater, sequence as under, may be followed:
Click the
Select the user type
Enter the password.
Finally click the “OK”.
A message Logged in successfully will appear on the screen after
successful login. There are two types of users viz. and
SUPERVISOR. If user logged in as an ADMINISTRATOR, all
the functions can be performed through the password for both users is
SUPERVISOR is allowed to perform monitoring of the status & alarms
but no change in configurat ion is permitted. can change password if so desired.
Next Generation Sig n a l Enhancem e nt
(Optional) located in the
It also enables monitoring the status.
(Optional) mou nted inside the repeater. The
“LOGIN” on the command bar.
(ADMINSTRATOR or SUPERVISOR).
ADMINISTRATOR
CMC. By default, the
SHYAM”.
However, the SUPERVISOR
II) Configuration
Configuring system means setting the system parameters for operation
as per the requirement at site.
Click on the command bar to display the configuration window, which
allows access to all the confi gurable repeater parameters . for configuration of parameters.
. Page All Rights Reserved Shyam Telecom Limited 12/43
SET is for updating the repeater parameters.
User can login
READ is for confirming the parameters set during the
configuration.
Information as detailed below can be incorporated after the
Next Generation Sig n a l Enhancem e nt
“CONFIGURATION” window is activated:
Figure 3: Login Repeater
a.
Repeater ID: User can assign a unique repeate r ID to each repeater
installed. Up to
Repeater Location: User can assign the address of location where
b.
repeater is installed. Up to
10 characters are allowed in this field. (Figure 4)
30 characters are allowed in this field.
(Figure 4)
Sub Band ON/OFF Settings: The system can be equip ped up to s ix
c.
sub bands; the sub bands equipped are specified as while others remain in
d.
Sub Band (UL/DL Frequency Bands) Settings: The frequency
bandwidths of all the 6 sub bands or loaded sub bands in are defined. (Figure 6)
OFF mode. (Figure 5)
ON in this window
UL & DL
. Page All Rights Reserved Shyam Telecom Limited 13/43