Shyam Telecom BTSLINK-208 User Manual

r
A
A
A
A
Next Generation Signal Enhancement
OPTICAL / MOU Series / BTS LINK
OOPPEERRAATTIIOONN && IINNSSTTAALLLLAATTIIOONN MMAANNUUAALL
BBTTSS LLiinnkk ®® --220088
MOU
DDIISSTTRRIIBBUUTTEED
FFIIBBEERR OOPPTTIICCAALL
D
NNTTEENNN
N
SSYYSSTTEEMMwwiitthh88DDBBRROOUUss
DBROU
5920 0020 200 April 2008
The information contained herein is proprietary to Shyam Telecom Limited. Unauthorized access, copy, and replication are prohibited. This document must not be copied in whole or part by any means or it shall not be disclosed o divulged to any third Party without the prior written consent of Shyam Telecom
Limited.
All Rights Reserved Shyam Telecom Limited Page 1 / 40
Proprietary Information
Contents
Next Generation Signal Enhancement
1. DOCUMENT HISTORY......................................................................................2
2. DISCLAIMER................................................................... ...................................3
3. SAFETY INSTRUCTIONS AND WARNINGS ........................................... ........4
3.1. P
ERSONNEL SAFETY
3.2. E
QUIPMENT SAFETY
3.3. E
LECTROSTATIC SENSITIVITY
.......................................... ...........................................4
........................................... ...........................................4
........................................ ................................5
4. INTRODUCTION ................................................. ...............................................5
4.1. P
URPOSE
4.2. S
COPE
4.3. D
EFINITIONS.................................................................................................6
4.4. R
EFERENCES
4.5. G
ENERAL
.......................................... ...........................................................5
.......................................... ...............................................................6
........................................ .......................................................6
.......................................... ...........................................................7
5. FUNCTIONAL DESCRIPTION OF BTS LINK-208 REPEATER.......................7
5.1. G
5.2. I
ENERAL DESCRIPTION
NDOOR/OUTDOOR COVERAGE .................................................. ....................9
......................................... .......................................7
6. TO GET STARTED-BASIC SOFTWARE CONTROL OF THE SYSTEM.......11
6.1. G
6.2. T
6.3. B
ENERAL ...................................................................................................11
ERMINAL SET-UP LOCK DESCRIPTION
.......................................... .............................................11
......................................... .........................................21
7. BTS LINK-208 REPEATER SPECIFICATIONS.............................................24
7.1. E
LECTRICAL SPECIFICATIONS
7.2. E
LECTRICAL SPECIFICATION POWER REQUIREMENT
7.3. E
XTERNAL ELECTRICAL/OPTICAL INTERFACE
7.4. M
7.5. E
7.6. C
7.7. S
ECHANICAL SPECIFICATION..................................................... ..................24
NVIRONMENTAL SPECIFICATION ONTENTS OF DELIVERY AFETY PRECAUTIONS-HANDLING OPTICAL EQUIPMENT
-RF & O
PTICAL
...............................................24
.....................................24
...............................................24
........................................... ......................25
............................................ .................................25
...............................25
8. INSTALLATION............................................................... .................................26
8.1. P
REPARATION SHEET-PRE INSTALLATION.....................................................26
8.2. MOU I
8.3. O
8.4. I
8.5. D
8.6. C
NSTALLATION
PTICAL FIBER CABLE LAYING ....................... .............................................29
NSTALLATION
& DON’T DOS......................................... .............................................31
OS
HECKLIST-POST INSTALLATION..................................................................32
-DBROU...............................................................................30
........................................... .........................................27
9. SYSTEM MAINTENANCE ...............................................................................34
9.1. G
9.2. P
ENERAL ...................................................................................................34
REVENTATIVE MAINTENANCE
........................................... ..........................34
1. Document History
Document Number
Document Name
Date Compiled
by
Approved by
Revision
5920 0020 200 BTS Link- 208 April Inderjit D.S.Nagi
All Rights Reserved Shyam Telecom Limited Page 2 / 40
Next Generation Signal Enhancement
Repeater 2008
Revision Revised Section Date
Intentionally Left Blank
2. Disclaimer
Every attempt has been made to make this material complete, accurate, and up-to-date. Users are cautioned, however, that Shyam Telecom Limited reserves the right to make changes without notice and shall not be responsible for any damages including consequential, caused by reliance of
All Rights Reserved Shyam Telecom Limited Page 3 / 40
Next Generation Signal Enhancement
the contents presented, including, but not limited to, typographical, arithmetic al, or listing errors.
Product name(s) referenced in this document may be trademarks or registered trademarks of their respective companies, and are hereby acknowledged.
In areas with unstable power grids (mains) all repeaters must be installed with a voltage regulator ensuring a constant voltage level at the repeater power input. A maximum voltage deviation should remain within the input range to the repeaters for warranty purposes.
All antennas must be installed with lighting protection. Damage to internal modules, as a result of lightning is not covered by the warranty.
All specifications are subject to change without prior notice
3. Safety Instructions and Warnings
3.1. Person n el Safety
Before installing or replacing any equipment, the entire manual should be read and understood. The user needs to supply the appropriate AC power to the Repeater. Incorrect AC power settings can damage the repeater and may cause injury to the user.
Throughout this manual, there are
"Caution"
warnings,
"Caution"
attention to a procedure or practice, which, if ignored, may result in injury or damage to the system or system component or even the user. Do not perform any procedure preceded by a "Caution" until the described conditions are fully understood and met.
calls
3.2. Equipment Safety
When installing, replacing or using this product, observe all safety precautions during handling and operation. Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product.
Shyam Telecom Limited
assumes no liability for the customer's failure to comply with these precautions. This entire manual should be read and understood before operating or maintaining the repeater system.
CAUTION
It calls attention to a procedure or practice which, if not followed, may result in personal injury, damage to the system or damage to individual components. Do not perform any procedure preceded by a
All Rights Reserved Shyam Telecom Limited Page 4 / 40
Next Generation Signal Enhancement
CAUTION
until described conditions are fully understood and met.
3.3. Electr o sta t i c S e n sitivity
CAUTION
ESD = ELECTROSTATIC DISCHARGE SENSITIVE DEVICE
Observe electrostatic precautionary procedures. Semiconductor transmitters and receivers provide highly reliable
performance when operated in conformity with the intentions of their design. However, a semiconductor may be damaged by an electrostatic charge inadvertently imposed by careless handling.
Static electricity can be conducted to the semiconductor chip from the centre pin of the RF input connector, and through the AC connector pins. When unpacking and otherwise handling the Repeater, follow ESD precautionary procedures including the use of grounded wrist straps, grounded workbench surfaces, and grounded floor mats.
4. Introduction
4.1. Purpose
The purpose of this document is to describe the electrical and mechanical specifications, operation and maintenance of the BTS Link-208 Repeater.
All Rights Reserved Shyam Telecom Limited Page 5 / 40
Next Generation Signal Enhancement
4.2. Scope
This document is the product description of the Shyam BTS Link-208 Repeater.
4.3. Definitions AGC
ALC APC BTS CDMA CMC DBROU DCS DL
Automatic Gain Control Automatic Level Control Automatic Power Control Base Transceiver Station Coded Division Multiple Access Configuration & Monitoring Console software Dual Band Remote Optical Unit Digital Communication System Downlink signal (from base station via repeater to mobile station)
EGSM ETSI FDF GSM IMD LAC LED LNA LO MOU MS NMS PCN PCS PSU RF RMS ROU RSSI UL (Uplink)
Extended Global System for Mobile Communication European Telecommunications Standard Institute Fiber Distribution Frame Global System for Mobile communication Inter Modulation Distortion Location Area Code of the BTS site Light Emitting Diode Low Noise Amplifier Local Oscillator Master Optical Unit Mobile Station Network Management System Personal Communication Network Personal Communication System Power Supply Unit Radio Frequency Remote Management System Remote Optical Unit Received Signal Strength Indication Uplink signal direction (from mobile station via repeater to base station)
UMTS
Universal Mobile Telecommunication System
4.4. References
[1] ETS 300 086.
Radio Equipment and Systems Land mobile service Technical characteristics and test conditions for radio equipment with an internal or external RF connector intended primarily for analogue speech.
All Rights Reserved Shyam Telecom Limited Page 6 / 40