ACCUMULATOR TANK: Model 182
Typical Accumulator Installations
Accumulator installed next to pump
INSTALLATION MANUAL
The SHURflo Accumulator tank is a bladder type pressure storage vessel and/or pulsation -dampening device designed to
hold water under pressure. The accumulator tank provides additional water storage to assist the pump in meeting the total
demands of the system. It extends pressure switch-controlled pump life by reducing pump on-off pulsation.
NOTE: This product is not recommended for use with a 4900 or 5900 Series Smart Sensor Pump.
• See Product label and Specifications section on page 2 for factory pre -charge pressure. Do not exceed
40 psi [2.7 bar] pressure for long-term storage, shipping, or during system non-use.
• It is recommended the pre-charge be checked seasonally, or any time the accumulator does not appear to be
functioning properly. Temperature extremes and changes in altitude can affect accumulator pressure and
performance. Use a standard tire pressure gauge to check the pressure. The valve stem cap MUST be tight to
prevent air leakage.
• The accumulator may be placed anywhere in the pressurized side of the plumbing. It should be installed after the
pump and before any filters or check valves that can add backpressure to the pump or system. The ports are nondirectional in flow and do not have to be plumbed in line (one side can be capped).
• The accumulator can be mounted in any position. However, for complete sanitizing/winterizing, the recommended
mounting position is with pre -charge valve stem up. Do not freeze or mount near a high heat source.
• Threaded fittings (plastic/nylon only) should be torqued approximately 1/2 to 1 turn after hand-tightened. Never
exceed 6 ft/lbs [88 Nm] of torque on the ports. Plumb the system using high pressure (2x pump rating), braided,
flexible tubing to minimize vibration/noise.
RV/MARINE APPLICATIONS WITH PRESSURE SWITCH -CONTROLLED PUMPS
The accumulator contributes to longer pump life, less noise, less amperage draw, and reduced water pulsation. The most
efficient use of the accumulator occurs with the pre-charge set at the SAME pressure as the pump’s pressure switch “turn
on” setting. Typically, a 45 psi [3 bar] pump will turn on around 30 psi [2.07 bar]. Therefore, the pre-charge should also be
30 psi [2.07 bar]. The pre-charge MUST be set in a “static” conditio n (pump off and at least one water fixture opened).
Depending on pre-charge pressure to the accumulator, in relation to the pump turn on/off pressures, stored liquid is about
2 to 4 oz. [60-120 ml]. If accumulator tank pre -charge exceeds pump turn on pressure, the liquid volume is reduced.
WATER HAMMER APPLICATIONS
When used as a dampening device/water hammer or noise suppressor, the pre-charge should be set at the operating
(dynamic) pressure. Place a gauge in the offending plumbing where the accumulator can be mounted. Adjust the valve so
the noise is generated and read the pressure. Set the pre-charge to the observed pressure, remove the gauge, and install
the accumulator. Refer to SHURflo Service Bulletin #1024 for more application information.
Valve
Base
Accumulator installed with tee fitting
NPSM
Dual swivel included
in retail pack.
911-731-E 03/09 ECN 16260 Page 1 of 2
182 Accumulator
tank and cut ½” flex line on outlet side of pump.
Use hose clamps to tighten hose to fittings.
port is
capped
Tee installation: Water does not need to go
through accumulator. Cap one end of tank and
install as shown. Tank still adds pressurized
volume to system.
ACCUMULATOR TANK: Model 182
INSTALLATION MANUAL (cont.)
TROUBLESHOOTING
SYMPTOMS POSSIBLE SOLUTIONS
Does not function; pump cycles rapidly Check air pressure. Add or remove air as necessary.
Water leaks from valve Diaphragm is torn or has a hole. Replace accumulator.
Does not hold air pressure Screws loose, air valve, torn/hole in diaphragm. Replace accumulator.
Leaks from fittings or ports Check fitting connection. Ports must seal on internal port taper,
Ports should not be sealed on threads with NPT fittings
TESTING AIR PRESSURE
Check air pressure with pump off and one or more faucets open [no water pressure in the system]. Adjust pressure as
needed. If unit leaks water from air valve or does not hold pressure, unit must be replaced.
NOTE: There are no replacement parts or kits for this accumulator. If it is not working, it must be removed or
replaced.
WINTERIZING
To winterize, drain all water from the system. Blow system out with low -pressure air, or add potable water anti-freeze.
Never use automotive anti-freeze. Death or severe injury can occur.
SPECIFICATIONS
Maximum Working Pressure: 125 psi [25 bar]
Pre-Charge Pressure: Models 182-100 & 182 -200: 30 psi [2.07 bar]
Models 182-102 & 182 -202: 20 psi [1.4 bar]
Total Volume: (gas/liquid): 21 oz. [620 ml]
Temperature Range:
34-120° F [1-49°C]
Diameter: 3 3/4” [95 mm]
Length: 8 3/4” [22 cm]
Listings: CSA & NSF listed
Housing Material: Nylon
Bladder Ma terial: Butyl
Ports: 1/2-14NPSM -Male
Mounting Bracket:
Two 7/32" [5.3 mm] φ holes at 4-1/16" [103 mm] centerline apart
LIMITED WARRANTY
SHURflo warrants the 182 series accumulator to be free from material and workmanship defects (under normal use and service) for a
period of one (1) year from the date of manufacture or one (1) year use, with proof of purchase, not to exceed two (2) years in any
event.
The limited warranty will not apply to accumulators that were improperly installed, misapplied, or are incompatible with components or
liquid not manufactured by SHURflo. Failure due to foreign debris is not covered under the terms of this limited warranty. SHURflo will
not warrant any accumulator, which is physically damaged or altered outside the SHUR flo factory. SHURflo’s obligation under this
warranty policy is limited to the repair or replacement of the accumulator. SHURflo is not responsible nor will it reimburse for labor
necessary to remove and reinstall an accumulator if found defective.
This limited warranty covers products distributed within the United States of America. Other world market areas should consult with
their distributors for any deviation from this document.
SHURflo, LLC Headquarters
5900 Katella Ave.
Cypress, CA 90630
Phone (562) 795-5200 Toll Free (800) 854-3218
FAX (562) 795-7554
SHURflo reserves the right to update specifications, prices, or make substitutions.
SHURflo East
52748 Park Six Court
Elkhart, IN 46514-5427
Phone (562) 795-5200 Toll Free (800) 854 -3218
FAX (574) 264-2169
© 2005 All rights reserved
SHURflo Europe, Middle East, Africa
Pentair Water Belgium bvba,
Industriepark Wolfstee, Toekomstlaan 30
B-2200 Herentals, Belgium
Phone +32 -14-283500
Fax +32-14-283505
911-731-E Page 2 of 2