The SZ 6104 Switcher is used to connect together two central units for installa­tions that share resources and for advanced system configurations. Two sepa­rate systems are routed to the SZ 6104 Switcher, so when one CU is turned off, the other will automatically begin operating the equipment as a single large system. This is useful for collapsible rooms that may operate occasionally as one large room, or for providing redundancy with a backup CU. For remote manage­ment, the SZ 6104 connects to an external control system (AMX, Crestron).
Advantages to Using the SZ 6104
Partitioned Rooms
The Switcher simplifies the installation in a partitioned room. The space is set up as a two standalone systems that connect together via the SZ 6104. To use the entire space for a large event, simply turn off one CU and the switcher automatically operates the entire system from a single CU.
Multiple Rooms
Multiple SZ 6104s are used to connect several rooms together, functioning as a patch panel that can be controlled remotely.
Redundancy
For security, the switch enables the connection of a backup CU for a redundant setup. If one CU is turned off or loses power, the switch instantly selects the other device to maintain system operation.
Advanced Setup
The switcher is useful in many installations where a single resource is shared with multiple CU configurations, such as a shared interpreter room.
Features
The SZ 6014 Switcher has the following main features:
• Automatic- or manual-controlled switching
• Adjustable front-panel DIP switches and manageable from a third party external controller (AMX/Crestrion)
• Front-panel status indicators
• Delay setting protects the DCS-LAN equipment when switching between CUs
Specifications
Front Panel
Back Panel
Mechanical
Dimensions (H x W x D) 41,3 x 288 x 128 mm
Weight ??? g
Temperature range 5° to 40° C
Color Black
Electrical
Power Supply From DCS-LAN
Power Consumption 6W (with four relays on)
Switches
Approvals KC, CCC, CE, cULus, TUV
SZ 6104 Interface
• One Local/Remote switch
• Three on/off switches
How To Order
SZ 6104 DCS-LAN Switcher 15 09 05800
Europe, Middle East, Africa:
Shure Europe GmbH Jakob-Dieffenbacher-Str. 12, 75031 Eppingen, Germany
Phone: 49-7262-92490 Fax: 49-7262-9249114 Email: info@shure.de
PT. GOSHEN SWARA INDONESIA
Kompleks Harco Mangga Dua Blok L No. 35 Jakarta Pusat
I.16.GSI31.00501.0211
Loading...