GENERAL DESCRIPTION
The Shure® SM137 is a versatile, flat-response cardioid probe microphone with an ultra-thin diaphragm. Its frequency response combines smooth high-end and tight, controlled low-end. A 15 dB pad provides natural, consistent sound reproduction in both acoustic and high-volume performance applications.
FEATURES
• Cardioid polar pattern to reduce the pickup of unwanted sounds
Ultra-thin, 2.5 μm 24 karat gold-layered, low mass Mylar® diaphragm for superior transient response
• Class A, discrete, transformerless preamplifier for transparency, extremely fast transient response, no crossover distortion, and minimal harmonic and intermodulation distortion
• Premium electronic components, including gold-plated internal and external connectors
• Two-position switchable pad (0 dB and 15 dB) for handling extremely high sound pressure levels (SPLs)
PERFORMANCE CHARACTERISTICS
• Extended frequency response
• Low self-noise
• Exceptional low-frequency reproduction
• Can withstand high sound pressure levels (SPLs)
• High output level
• No crossover distortion
• Superior common mode rejection and suppression of radio frequency interference (RFI)
Mounting the Microphone
Thread the supplied stand adapter onto a floor or boom stand and insert the microphone.
NOTE: Since this microphone reproduces ultra-low frequencies, use an isolating shock mount (available at www.shure.com) to reduce low-frequency mechanical vibrations transmitted through the stand.
Setting Attenuation
The attenuation switch lets you reduce the signal level without altering the fre­quency response. This can prevent extremely loud sounds from overloading the microphone.
0 dB For “quiet” to “normal” sound levels.
-15 dB For use with extremely loud sound sources such as drums, horns, or loud
guitar cabinets.
Integral Pop Filter
The microphone grille consists of 3 separate mesh layers that act as an integral pop filter. This helps reduce wind and breath noise. Depending on the performer, an external pop-protection screen or windscreen may be necessary when close­miking vocalists.
Load Impedance
Maximum SPL capability, output clipping level, and dynamic range varies with the input load impedance of the preamplifier to which you connect the microphone.
Shure recommends a minimum input load impedance of 1000 Ω, and most modern
microphone preamplifiers meet this requirement. Higher impedance results in bet­ter performance for these specifications.
APPLICATIONS
• Electric guitar amplifiers
• Brass and woodwind instruments
• Orchestras, choirs, and wind ensembles
• Overhead miking of drums and percussion instruments
• Close-miking of acoustic instruments such as piano, guitar, violins, drums, and percussion
• Low-frequency instruments such as double bass and kick drum
• Room ambience pick-up (guitar amplifier or drums)
Note: Sound quality is strongly affected by microphone location and room acous­tics. To achieve the best overall sound for a particular application, it may be neces­sary to experiment with microphone placement and room treatments.
Power Requirements
This microphone requires phantom power and performs best with a 48 Vdc supply (IEC-268-15/DIN 45 596). However, it will operate with slightly decreased head­room and sensitivity with supplies as low as 11 Vdc. Most modern mixers provide phantom power. Phantom power can only be transmitted through a cable termi­nated with XLR connectors at each end.
3
SPECIFICATIONS CERTIFICATION
Type Electret Condenser Frequency Response 20 to 20,000 Hz Polar Pattern Cardioid
Output Impedance 150 Ω (actual)
Sensitivity
(at 1 kHz, open circuit voltage)
Maximum SPL
(1 kHz at 1% THD)
Signal-to-Noise Ratio
(referenced at 94 dB SPL at 1 kHz)
Dynamic Range
(at 1 kHz)
Common Mode Rejection
(10 Hz to 100 kHz)
Clipping Level
(20Hz-20 kHz at 1% THD)
Self Noise
(typical, equivalent SPL, A-weighted)
Polarity Positive pressure on diaphragm produces positive
Weight Net: 195 g (6.9 oz.)
Switch Attenuator: −15 dB Connector Three-pin professional audio (XLR), male Power Requirements 48 Vdc phantom, 5.2 mA
−41 dBV/Pa
1 Pascal=94 dB SPL
1000 Ω load: 139 dB (154 dB, Pad on) 2500 Ω load: 144 dB (159 dB, Pad on)
75 dB S/N ratio is difference between 94 dB SPL and
equivalent SPL of self noise, A-weighted
1000 Ω load: 120 dB 2500 Ω load: 125 dB
> 50 dB
1000 Ω load: 3 dBV 2500 Ω load: 9 dBV
THD of microphone preamplifier when applied input signal is equivalent to cartridge output at specified SPL
19 dB
voltage on pin 2 with respect to pin 3
Eligible to bear CE Marking. Conforms to European EMC Directive 2004/108/EC. Meets Harmonized Standards EN55103-1:1996 and EN55103-2:1996, for residen­tial (E1) and light industrial (E2) environments.
The Declaration of Conformity can be obtained from:
Authorized European representative: Shure Europe GmbH Headquarters Europe, Middle East & Africa Department: EMEA Approval Jakob-Dieffenbacher-Str. 12 75031 Eppingen, Germany Phone: 49-7262-92 49 0 Fax: 49-7262-92 49 11 4 Email: info@shure.de
ACCESSORIES AND PARTS
Furnished Accessories
Storage Bag 95C2313 Windscreen A3WS Swivel Stand Adapter A25D
Optional Accessories
Shock Stopper™ Isolation Mount A55M, A55HM Popper Stopper™ PS-6
4
DESCRIPTION GÉNÉRALE
Le Shure® SM137 est un microphone sonde cardioïde à réponse uniforme polyva­lent, équipé d’un diaphragme ultra-mince. Sa réponse en fréquence combine aigus réguliers et graves profonds bien contrôlés. Son atténuateur de 15 dB garantit une reproduction naturelle et stable du son lors de concerts acoustiques ou aux niveaux sonores élevés.
Montage du microphone
Visser l’adaptateur de pied fourni sur un pied ou un flexible et insérer le microphone.
REMARQUE : Ce microphone reproduit les fréquences ultra-basses ; utiliser une monture antichoc isolante (disponible sur www.shure.com) pour réduire les vibra­tions mécaniques à basse fréquence transmises par le pied.
CARACTÉRISTIQUES
• La courbe de directivité cardioïde minimise le captage des sons indésirables.
• Le diaphragme Mylar® ultra-mince, à couche d’or 24 carats de 2,5 µm et de faible masse assure une réponse transitoire inégalée.
• Préamplificateur discret, sans transformateur, de classe A, assurant la transparence, une réponse transitoire extrêmement rapide, l’absence de distorsion de recoupement et des distorsions harmoniques et d’intermodulation minimales
• Composants électroniques haut de gamme, y compris des connecteurs internes et externes plaqués or
• Sélecteur d’atténuation commutable à deux positions (0 et 15 dB) permettant de prendre en charge des niveaux de pression acoustique (SPL) extrêmement élevés
CARACTÉRISTIQUES DES PERFORMANCES
• Réponse en fréquence étendue
• Bas niveau de bruit propre
• Reproduction des basses fréquences exceptionnelle
• Supporte des niveaux de pression acoustique (SPL) élevés
• Niveau de sortie élevé
• Aucune distorsion de recoupement
• Réponse polaire régulière
• Rejet en mode commun et suppression des parasites haute fréquence exceptionnels
Réglage de l’atténuation
Le sélecteur d’atténuation permet de réduire le niveau du signal sans modifier la réponse en fréquence. Ceci évite que des sons extrêmement puissants entraînent une surmodulation du microphone.
0 dB Pour les niveaux sonores « faibles » à « normaux ».
-15 dB Pour les sources sonores extrêmement bruyantes, telles que les batteries,
les cuivres ou les caisses de guitares à forte résonance.
Filtre anti-bruit intégré
La grille du microphone consiste en 3 couches de mailles distinctes agissant comme filtre anti-bruit intégré. Cela contribue à réduire les bruits de vent et de res­piration. Suivant l’utilisateur, un écran anti-bruit externe ou une bonnette anti-vent peut s’avérer nécessaire pour enregistrer des voix à faible distance.
Impédance de charge
La capacité NPA maximum, le niveau d’écrêtage en sortie et la gamme dynamique varient avec l’impédance de charge d’entrée du préamplificateur auquel le mi­crophone est branché. Shure recommande une impédance de charge d’entrée
d’au moins 1000 Ω, disponible sur la plupart des préamplificateurs de microphone
modernes. Une impédance élevée donne de meilleures performances pour ces spécifications.
APPLICATIONS
• Amplificateurs de guitare électrique
• Cuivres et les bois
• Orchestres, choeurs et ensembles d’instruments à vent
• Prise de son en overhead de batteries et percussions
• Prise de son en proximité d’instruments acoustiques tels que le piano, la guitare, les violons, la batterie et les percussions
• Instruments à basse fréquence tels que la contrebasse et la grosse caisse
• Prise de son d’ambiance (amplificateur de guitare ou batterie)
Remarque : Le placement du microphone et l’acoustique des locaux ont des répercussions significatives sur la qualité du son. Pour obtenir le meilleur son dans une application donnée, il peut être souhaitable de faire des essais de placement du microphone et de traitements de la pièce.
Alimentation
Ce microphone exige une alimentation fantôme et donne les meilleurs résultats avec une alimentation de 48 V c.c. (IEC-268-15/DIN 45 596). Cependant, l’usage est possible avec une alimentation minimale de 11 V c.c., au prix d’une capacité d’aménagement et d’une sensibilité légèrement réduites. La plupart des mélan­geurs modernes offrent une alimentation fantôme. L’alimentation fantôme ne peut être transmise que par l’intermédiaire d’un câble pourvu de connecteurs XLR à chaque extrémité.