INSTALLATION - RK100PK (BLACK), RK100PKW (WHITE)
The RK100PK and RK100PKW preamp comes assembled for use with microphones using a miniature 4-pin connector. To wire a microphone cable directly to the preamp, follow these instructions:
1. the case.
Remove the cap (C) by removing the set screw (B) with
2. the provided hex wrench (.05 in.).
Preampler Kit User Guide
5.
Insert the rubber ex relief (G) into the cap (C) and feed
through the microphone cabling.
Note: You will need to reuse the rubber ex relief from your old preamp. If the rubber ex relief is unavailable, please contact the
Shure Service Department.
FIGURE 3
6.
Solder the wires directly back onto the circuit board. Match wires as marked on the circuit board using the fol­lowing key:
R = RED
B = BLACK
S = (GROUND) SHIELD
FIGURE 1
Push the circuit board out from the case interior to expose
3. the black and red wires (D).
Unsolder the wires from the circuit board (E).
4.
FIGURE 4
7.
Push the circuit board back into the case, making sure that the set screw (A) is lined up with the screw hole in the side of the case (if the circuit board does not go in all the way, twist it slightly until the screw and hole are aligned). Raise the set screw (A) by turning clockwise
so that the preamplier is held securely in place. Screw
on the cap (C). Do not use the set screw with the cap.
FIGURE 2
27A3252 (Rev. 1) Printed in U.S.A. ©2007, Shure Incorporated
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 847-600-2000 U.S. Fax: 847-600-1212 Int’l Fax: 847-600-6446 Europe, Middle East, Africa: Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414 Asia, Pacific: Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055