Shure PGA58 User Manual

PG ALTA SERIES
WIRED MICROPHONE
TM
PGA 58 USER GUIDE
© 2015 Shure Incorporated 27A24476 (Rev. 3)
MONITOR
P.A. LOUDSPEAKER
On
Off
PG Alta Microphones
Congratulations on the purchase of a new Shure PG Alta series microphone. The PG Alta series delivers professional quality audio at an affordable price, with solutions for capturing nearly any source, including voice, acoustic instruments, drums, and amplified electric instruments. Suitable for live and studio applications, PG Alta microphones are built to last, and meet the same rigorous quality testing standards that make all Shure products trustworthy and reliable.
General Rules for Use
• Do not cover any part of the microphone grille with your hand, as this will adversely affect microphone performance.
• Aim the microphone toward the desired sound source (such as the talker, singer, or instrument) and away from unwanted sources.
• Place the microphone as close as practical to the desired sound source.
• Work close to the microphone for extra bass response.
• Use only one microphone to pick up a single sound source.
• For better gain before feedback, use fewer microphones.
• Keep the distance between microphones at least three times the distance from each microphone to its source (“three to one rule”).
• Place microphones as far as possible from reflective surfaces.
• Add a windscreen when using the microphone outdoors.
• Avoid excessive handling to minimize pickup of mechanical noise and vibration.
Proximity Effect
Directional microphones progressively boost bass frequencies as the microphone is placed in closer proximity to the source. This phenomenon, known as proximity effect, can be used to create a warmer, more powerful sound.
Avoiding Pickup of Unwanted Sound Sources
Place the microphone so that unwanted sound sources, such as monitors and loudspeakers, are directly behind it. To minimize feedback and ensure optimum rejection of unwanted sound, always test microphone placement before a performance.
Recommended Loudspeaker Locations for Cardioid
Microphones
On/Off Switch
2
Specifications
20
Hz
1000 Hz
Type
Dynamic (moving coil)
Frequency Response
50 to 16,000 Hz
Polar Pattern
Cardioid
Output Impedance
150 Ω
Sensitivity
at 1 kHz, open circuit voltage
-55 dBV/Pa¹ (1.79 mV)
Polarity
Positive pressure on diaphragm produces positive voltage on pin 2 with respect to pin 3
Weight
294 g (10.37oz.)
Switch
On/Off Switch
Connector
Three-pin professional audio (XLR), male
Environmental Conditions
Operating Temperature
Relative Humidity
1 Pa=94 dB SPL
-20° to 165°F (-29° to 74°C)
0 to 95%
Optional Accessories and Replacement Parts
Microphone Clip A25D
5/8" to 3/8" Thread Adapter 31A1856
7.6 m (25 ft.) Cable (XLR-XLR) C25J
TRIPLE-FLEX® Cable and Plug 7.6 m (25
C25F
ft.)
Grille RPMP58G
PGA58 Replacement Grille RPM150
Certifications
This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking.
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance
Authorized European representative: Shure Europe GmbH Headquarters Europe, Middle East & Africa Department: EMEA Approval Jakob-Dieffenbacher-Str. 12 75031 Eppingen, Germany Phone: 49-7262-92 49 0 Fax: 49-7262-92 49 11 4 Email: EMEAsupport@shure.de
15
0,6 m (2 ft.) from sound source
10
5
0
-5
dB
-10
-15
-20
-25
-30
20 100 1k 10k 20k
Typical Frequency Response
166 mm (6.54 in)
55.1 mm diameter (2.17 in.)
Overall Dimensions
Typical Polar Pattern
3