Shure PA421SWB User Manual

Page 1
Model PA421SWB
PA421SWB
PSM Antenna Combiner
470-952MH
MAINOUT
ACTIVE COMBINER
1
2
3
4
50OHMS
POWER
INPUT SIGNAL
User Guide
PA421SWB
Antenna Combiner
27A12082 (Rev. 1) Printed in U.S.A. ©2008 Shure Incorporated
Page 2
! IMPORTANT SAFETY INSTRUCTIONS !
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Install in accordance with the manu­facturer's instructions.
8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. DO NOT defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your out­let, consult an electrician for replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer .
12.
13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is dam­aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.
USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
OVERVIEW
WARNING:
Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The
safety certifications do not apply when the operating voltage is changed from the factory setting.
POWER
The Shure PA421SWB Antenna Combiners actively combine antenna outputs from up to four PSM wireless transmitters to a single antenna, improving RF performance and reducing rack clutter.
INSTALLATION
Before installing, set the front panel power switch to OFF. (See Figure 1)1. Using the supplied power cable connect the unit to an AC power source.2. To use the device set the front panel power switch to ON. The power light will illuminate.3. Before disconnecting the unit from the AC power source, or when not in use, power the unit OFF. 4.
PA421SWB Benefits
Reduction of intermodulation artifacts for cleaner RF environment • and more channels on air
Simplified antenna placement• Power distribution•
Figure 1
2
Switch Off
Page 3
4-TO-1 COMBINING FOR PSM TRANSMITTERS
®
PA 805W B
N108
Using the supplied BNC-BNC cables, connect the Antenna Output 1. of each transmitter to the Antenna Inputs of the PA421SWB (See Figure 2).
Attach an antenna to the MAIN Out of PA421SWB. For wideband 2. applications, use PA805SWB directional antenna (Figure 2).
Connect the PA421SWB to a power outlet using one of the supplied 3. power cables. The PA421SWB contains a universal power supply to operate anywhere in the world.
If you have a Shure PSM system that has the same power input 4. connectors as the PA421SWB power outputs, such as the PSM400, connect the PSM system to the PA421SWB via the supplied power cables (see figure 2). This replaces the need for an external power supply.
NOTE: The PA421SWB supplied power is 15 V and up to 660 mA.
Operating Temperature Range
NOTE: Electrical safety approval is based on a maximum ambient
temperature of 30°C.
Overall Dimensions 43.4 mm high x 398.8 mm wide x331.5 mm
Net Weight 4.53 Kg
Input/Output Connector Type BNC-type 4 input, 1 output ACTIVE Power Outputs (4) 15 VDC, 660 mA each
0° F (-18° C) to +135° F (+57° C)
deep (1 11/16 in. H x 15 11/16 in. W x
(10 lbs unpackaged, without power and
13 1/2 in. D)
RF cables)
FURNISHED ACCESSORIES
(4) 2 ft. Coaxial Cable (RG58C/U) (4) 2 ft. Output Power Cable 95B8420 120 VAC Power Line Cord 95A8389 230 VAC Power Line Cord 95A8247 240 VAC Power Line Cord (U.K.) 95A8713
UA802
OPTIONAL ACCESSORIES
AC Power
PSM Transmitters
50Ω BNC
Figure 2
NOTE: When the PA421SWB is powered on, the input signal indicators (1-4) on the front panel will illuminate if an active transmitter is connected to the corresponding input (1-4) on the back panel (Figure 2).
SPECIFICATIONS
RF Carrier Frequency Range System Gain +0/-5 dB Input AC Line Voltage 100-240 Vac, 50/60 Hz Maximum Input Line Power 120 W Maximum Current Drain 0.42-1.0 Amperes
(Amperes = 100 VA/Input AC Line Voltage)
Maximum RF Input Power 24 dBm (250 mW) per channel
Input Signal Indicator Threshold
Impedance
+4 dBm (2.5 mW), +2 dBm (1.6 mW) typical
470-952 MHz
50Ωnominal
Wideband Unidirectional Antenna (470-952 MHz)
10 ft. Coaxial Cable (RG-8X/U) PA725 25 ft. Coaxial Cable (RG-8X/U) UA825 50 ft. Coaxial Cable (RG-8X/U) UA850
Wide Band Omnidirectional Antenna (470-1100 MHz)
Helical Antenna HA-8089 (480-900 MHz)
HA-8241(944-952 MHz)
PA805SWB
UA860SWB
CERTIFICATIONS
PA421SWB: Certified to FCC Part 74 (FCC ID No. DD4PA421SWB). Certified in Canada by IC to RSS-123 AND RSS-102 (Certification No. IC: 616A-PA421SWB). UL LISTED to UL60065, 7th Edition and cUL LISTED to CAN/CSA E60065-00. Meets the Essential Requirements of the European R&TTE Directive 99/5/EC, eligible to bear CE mark. Meets EMC requirements of EN 301 489 Parts 1 and 9 and is GS-Certified to EN EN60065, 7th Edition. Conforms to Australian EMC requirements, eleigible to bear C-Tick mark (N108).
LICENSING
Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability depends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies.
THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFESSIONAL ENTERTAINMENT AND SIMILAR APPLICATIONS.
NOTE THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON SOME FREQUENCIES NOT AUTHORIZED IN YOUR REGION. PLEASE CONTACT YOUR NATIONAL AUTHORITY TO OBTAIN INFORMATION ON AUTHORIZED FREQUENCIES FOR WIRELESS MICROPHONE PRODUCTS IN YOUR REGION.
Licensing: Note that a ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements.
3
Page 4
www.shure.com
United States:
Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA
Phone: 847-600-2000 Fax: 847-600-1212 Email: info@shure.com
©2008 Shure Incorporated
Europe, Middle East, Africa:
Shure Europe GmbH Wannenäckestr. 28, 74078 Heilbronn, Germany
Phone: 49-7131-72140 Fax: 49-7131-721414 Email: info@shure.de
Asia, Pacific:
Shure Asia Limited Unit 301, 3rd Floor Citicorp Centre 18, Whitfield Road Causeway Bay, Hong Kong
Phone: 852-2893-4290 Fax: 852-2893-4055 Email: info@shure.com.hk
Canada, Latin America, Caribbean:
Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA
Phone: 847-600-2000 Fax: 847-600-6446 Email: international@shure.com
Loading...