Shure M96 LT User Manual

Page 1
-
P
r
"
1
~nn~on,eoulll~lon~~l~nnn
&
-
\
#
BIRADIAL ELLIPTICAL
Page 2
The Shure M96 LT Cartridge, mounts directly to Technics Linear Tracking Turn­tables such as Models
SL5, SL7, SLlO and SL15. This cartridge brings outstanding trackability and transparent frequency response to the Technics Linear Tracking Turntables.
La Shure M96 LT s'adapte directement sur les platines Technics SL5, SL7, SLlO et SL15, platines a bras tangentiel. Cette cellule apporte aux platines Technics, une formidable reporter
capacite de lecture et une reponse en frCquences tres etendue. Se
a
la page 8 pour plus ample information en Francais.
Das SHURE Tangential-Tonarmen.
Modell M96 LT paRt direkt zu Technics Plattenspielern mit
Zum Beispiel zu den Modellen SLS, SL7, SLlO und SL15. Dieser Tonabnehmer bietet hervorragende Abtastfahigkeit, einenglatten Frequen­zgang mit dem Tangential-Tonarm einiger Plattenspieler von Technics. Siehe
8
fijr
Seite
La Shure M96 LT se monta directamente en
weitere Hinweise in Deutsch.
10s giradiscos tangenciales Technics, Modelos SL5, SL7, SLlO y SLIS. Esta capsula consigue una extraordinaria habilidad de lectura y una transparente respuesta de frecuencias en 10s giradiscos tangenciales Technics. Vea en la pdgina 9 mas instrucciones en espaiiol.
Page 3
SPECIFICATIONS Frequency Response:
Typical Trackability
400 Hz
1,000 Hz - 44 cmlsec
Output Voltage Channel Balance: Channel Separation Optimum Load:
capacitance per channel. Load resistance can be up to 70,000 ohms with almost no audible change in frequency response. Total tone arm wiring and amplifier input circuit.
Inductance: DC Resistance: Tracking Force: Net weight: Replacement Stylus:
diamond tip, Yellow grip
700 millihenries
6 grams
20 to 20,000 Hz
(at 1.25 grams tracking force, in cmlsec peak velocity):
-
30 cmlsec
(at 1,000 Hz, 5 cmlsec peak velocity): 4.0 mV per channel
Within 2 dB
(minimum): 25 dB at 1,000 Hz
47,000 ohms resistance in parallel with 200 to 300 picofarads
1550 ohms
1.25 grams optimum; 1 5 grams maximum
N96LT with 5 x 18p(.0002 x .0007 in.), biradial elliptical nude
5,000 Hz - 41 crnlsec
10,000 Hz - 31 cmlsec
capac~tance includes both the
PREAMPLIFIER SETTING
The M96 LT is a moving magnet cartridge. If your Technics Linear Track~ng Turn­table has a preamplifier selector switch, (see Figure 2) be sure to set the switch to the moving magnet position
TRACKING FORCE
The M96 LT is designed to operate at a tracking force of 1.25 grams optimum. Do not use tracking forces heavier than 1.5 grams. Consult the turntable manufac­turer if you have any doubts about whether its tracking force is appropriate.
(MM)
MM
-MC
AMP
FIGURE
@hO
PHONO
OUT
2
Page 4
TELESCOPED SHANK AND HIGH-ENERGY MAGNET
The effective mass of the M96 telescoped shank structure and a new lightweight high-energy magnet (see Figure
3)
With no sacrifice in either electrical output level or required shank stiff­ness, the dynamic mechanical jm­pedance has been significantly reduc­ed. The outcome is flat frequency re­sponse and improved trackability in the critical mid and high frequencies.
TRACKABILITY
Trackability - the ability of the stylus to stay in contact with both groove walls- remains the single overwhelming measure of a cartridge's overall perfor­mance In the trackability chart (Figure recommended theoretical limits of record cutting velocities. The small scattered circles are the "hottest" recorded velocities actually measured on difficult-to­track records. Although a cartridge with moderate trackability will be able to track all the recorded velocities within the theoretical record-cutting limits, substantially higher trackability is obviously needed to track the recorded velocities actually found on today's discs.
LT
moving system has been lowered by utilizing a
TELESCOPED
SHANK
STYLUS CROSS SECTION
FIGURE
4),
the pyramidal shape represents the
HIGH-ENERGY
3
STYLUS CLEANING
Use a soft brush w~th an alcohold~st~lled water solu­t~on or Shure Stylus Clean~ng Solut~on (See your dealer and ask for the Shure Brush only from back to front as shown In F~gure Other commerc~al clean~ng solut~ons may cause stylus damage
STYLUS REPLACEMENT STYLUS CLEANING
Place the Technics Linear Tracking arm in a conve­nient position as follows.
1. With the lid closed, use the "manual" mode to move the arm to approximately the center of its travel.
2. Make certain the cartridge is cued "up" (raised off the record), and press the Off-On switch "Off."
3.
Raise the lid.
Replace the stylus as shown in Figure 6 Always hold the stylus only by the plastic grip; take care not to touch or damage the shank or diamond tip
SK-I, Stylus Clean~ng
Kit
)
5
FIGURE
kTDk
~
1
I
STYLUS REPLACEMENT
FIGURE
5
6
The trackability of the M96 LT at 1.25 grams is shown below
100 400 IK 4K IOK 20K
FREQUENCY
TRACKABILITY
FIGURE
IN
HERTZ
4
6
SPECIAL NOTE
As the only source of contact between the record groove and the balance of your high fidelity system, the stylus in your cartridge plays a critical role in the ultimate quality of sound reproduction. Additionally, because records can be irreparably damaged by a worn stylus, it is essential to ensure that your Shure stylus is in peak condition in order to preserve your records in perform at original operating specifications for many years with these simple maintenance steps:
1. Follow the stylus cleaning instructions given above
2. See your Shure dealer at least once a year for a checkup of your cartridge's stylus He'll clean it and inspect it for wear.
3
When ~t becomes necessary to replace your stylus, lnslst on a genulne Shure replacement grave flaws To be spec~f~cat~ons, look for the name SHUREO on the stylus grlp and the words "Th~s Stereo DYNETIC@ stylus 1s preclslon manufactured by Shure Brothers
"
on the stylus box
Inc
Extenswe testlng of ~m~tat~ons of Shure sty11 revealed numerous
certaln that your replacement stylus meets or~g~nal
"mint"condition. Your cartridge can
-
-+..----
Page 5
FULL
ONE-YEAR WARRANTY:
trey Avenue, Evanston, Illinois
Shure Brothers lncorporated ["Shure"),
60204,
warrants to the owner of this product that it
222
Har-
will be free, in normal use, of any defects in workmanship and materials for a period of one year from date of purchase. You should retain proof of date of pur­chase. Shure is not liable for any consequential damages. If this Shure product has any defects as described above, carefully repack the unit and return it prepaid to:
Shure Brothers Incorporated Attention: Service Department
1501
West Shure Drive
Arlington Heights, Illinois
60004
If you are not in the United States, return the unit to your dealer or Authorized
Service Center for repair. The unit will be repaired or replaced and returned to you
a
promptly, and if it cannot be repaired or replaced, you may elect to receive
re-
fund. This warranty does not include stylus wear.
PATENT NOTICE:
more of the following U.S. Patents:
4,270,758; 4,194,744; 4,275,888;
All Shure Styli and Cartridges are manufactured under one or
3,055,988; 3,077,521; 3,077,522; 3,463,889;
D193,854; D193.934; D201,803; D235.070;
D235.351; D235,352; D245.022; D245,433; D252,628; D254.004; D257,676;
D255,898; D258.586;
Copyright
27A1749 (AL)
1981,
other patents pending.
Shure Brothers Inc.