EASYFLEX EZB SERIES MICROPHONE
EasyFlex EZB
Specification Sheet
DESCRIPTION
FEATURES
AVAILABLE
MODELS
ARCHITECTS’
and
ENGINEERS’
SPECIFICATION
TL1047 (Rev. 3)
©2007 Shure Incorporated
Shure Easyflex EZB Series microphones are small, surface mounted electret condenser microphones designed
for mounting on conference tables, stage floors, and lecterns. Their wide frequency range makes them especially
suitable for picking up speech and vocals in sound reinforcement and recording applications.
• Flat frequency response across the vocal range for uncolored sound.
• Sleek, low-profile design for unobtrusive appearance.
• In-line preamp reduces visible size of microphone
• Available in either cardioid or omnidirectional models
EZB/C: Cardioid polar pattern.
EZB/O: Omnidirectional polar pattern.
The microphone shall be a small surface-mounted electret condenser microphone, with options for a cardioid
or omnidirectional polar pattern. The microphone shall have wide frequency response and a high sensitivity, making it ideal for use in challenging sound reinforcement and recording environments. The microphone shall include
an external preamplifier.
The microphone shall be designed so that it can be either set in place temporarily, or securely installed. The
microphone shall be available in both white and charcoal gray to blend with any surrounding.
The microphone shall be of the Shure Easyflex EZG series.
EasyFlex EZB Specification Sheet
500 1K 2K 5K 10K
20K
50 100 20020
dB
Hz
CARDIOID
OMNI
+10
0
–10
SPECIFICATIONS
Frequency Response
(Figure 1)
Polar Pattern
(Figure 1)
Output Impedance
(at 1 kHz)
Open Circuit Sensitivity
(at 1 kHz, ref. 1 V/Pascal*)
Maximum SPL (1 kHz at 1% THD, 1 kW load)
Maximum Equivalent Output Noise
(A-weighted at 1kΩ load)
Signal to Noise Ratio
(referenced to 94 dB SPL)
Dynamic Range (at 1 kΩ Load)
Common Mode Rejection
Preamplifier Output Clipping Level (1 kHz at 1%
THD, 1 kΩ load)
Polarity
Power Requirements
Environmental Requirements
Dimensions
Weight
Certification
50 to 17,000 Hz
Cardioid or Omnidirectional
Ω (
Rated at 150
Cardioid: -39.0 dB (11.2 mV)
Omni: -34.0 dB (20.0 mV)
*1 Pascal = 94 dB SPL
Cardioid: 122.5 dB
Omni: 117.5 dB
Cardioid: 23.0 dB
Omni: 17.5 dB
Cardioid: 71.0 dB
Omni: 76.5 dB
Cardioid: 99.5 dB
Omni: 100.0 dB
45 dB minimum
-12.0 dBV (0.25 V)
Positive sound pressure on diaphragm produces positive voltage on pin 2 relative
to pin 3 of output connector.
11 to 52 Vdc phantom, 2.0 mA
Operating Temperature Range:
-18
°
C to 57° C (0° F to 135° F)
Relative Humidity: 0 to 95%
2-15/16" L x 2-1/16 W x 17/32" H
1lb
Eligible to bear CE Marking. Conforms to European EMC Directive 89/336/EEC.
Meets applicable tests and performance criteria in European Standard EN55103
(1996) parts 1 and 2, for residential (E1) and light industrial (E2) environments.
170 Ω actual)
TL1047 (Rev. 3)
o
180
150
o
120
120
90
o
150
o
o
–20 dB
o
CARDIOID
60
30
o
–10 dB
30
0
OMNI
SHURE Incorporated http://www.shure.com
United States, Canada, Latin America, Caribbean:
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446
Europe, Middle East, Africa:
Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414
Asia, Pacific:
Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055
60
o
1000 Hz
90
o
o
o