Model R98B Replacement Cartridge for
K
Model 577 Series Microphones
CASE FRONT
RETAINING RING
TAB
CHASSIS MODULE
CARTRIDGE
TAB
CABLE
EXPLODED VIEW
FIGURE 1
DISASSEMBLY
MODEL R98 CARTRIDGE
SWITCH ASSEMBLY
O–RING
TWIN NUT
SWITCH BOTTOM
TOP CABLE CLAMP
BOTTOM CABLE CLAMP
CASE BAC
6. Bend the cartridge-retaining tabs outward (away from cartridge).
7. Solder the leads to the cartridge terminals. See Figure 2 for proper lead connections.
8. Insert chassis module in case front and switch button in case back.
9. Fasten case halves with previously removed screws.
The R98B is a replacement microphone cartridge for the 577B microphone. To replace the present cartridge with the R98:
1. Disassemble the case as described above.
2. Using a low-wattage (50 W or less) soldering iron,
unsolder the leads connected to the present cartridge.
3. Bend the two cartridge-retaining tabs inward (toward
cartridge).
4. Slide the cartridge out of the chassis module, remove
the retaining ring from around the screen, and remove the O-ring from the rear of the cartridge.
5. Place the retaining ring and the O-ring on the replace-
ment cartridge and slide the replacement cartridge into the chassis module.
MODEL 577B INTERNAL WIRING DIAGRAM
FIGURE 2
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446 Europe, Middle East, Africa: Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414 Asia, Pacific: Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055
©2005, Shure Incorporated
27C1593 (Rev. 5)
Printed in U.S.A.