Shure EPG-1139x Specification Sheet

ELECTRONICS
ELECTRONICS DISTRIBUTING
DISTRIBUTING
COMPANY INC.
COMPANY INC.
Product Data Sheet
Rose Electronics # EPG-1139(x)
The products referenced herein are “articles” under 29 CFR 1910.1200(c) and are not subject to OSHA's requirements for material safety data sheets under its Hazard Communication Standard, 29 CFR 1910.1200. This Product Data Sheet is provided as a service to our customers.
Identity: Lithium Ion Batteries Manufacturer: Models: EPG-1139x Rose Electronics Distributing Company, Inc. WH Rating: 8.82Wh 2030 Ringwood Avenue Date: 1/17/13 San Jose, CA 95131 Phone: 1-408-943-0200
Section II: Composition Information:
Rose Electronics EPG-1139x contains 1S1P Panasonic CGR18650EA
Component: Material: Formula Positive Electrode Lithium Cobalt Oxide LiCoO2 Negative Electrode Graphite C Electrolyte Ethylene Carbonate-Solvent C3H4O3 Diethyl Carbonate-Solvent C5H10O3 Lithium Hexaflurophosphate-Salt LiPF6
Section III: Hazards Information
Potentially hazardous materials are fully contained in a hermetically sealed case designed to withstand normal handling and use. Exposure could occur only if the battery or cells have been opened,
disassembled, crushed, burned, exposed to high temperatures (> 60o C or 140o F), or subjected to other types of abuse. Exposure to cell contents may be harmful under some circumstances. Follow instructions and precautions for safe use of the battery pack.
Section IV: First Aid Measures
If you get electrolyte in your eyes, flush with water for 15 minutes without rubbing and immediately contact a physician. If you get electrolyte on your skin wash the area immediately with soap and water. If irritation continues, contact a physician. If the battery is ingested, call the National Capital Poison Center (NCPC) at 202-625-3333 (Collect) or your local poison center immediately.
Section V: Firefighting Measures
In case of fire, you can use dry chemical, alcohol resistant foam or carbon dioxide fire extinguishers. Cooling the exterior of the batteries will help prevent rupturing. Burning of these batteries will generate toxic fumes. Fire fighters should use self-contained breathing apparatus. Detailed information on
2030 Ringwood Avenue ● San Jose, CA 95131 ● 800-632-4789 ● www.rosebatteries.com
fighting a lithium ion battery fire can be found in Guide 147 (Lithium Ion Batteries) of the US DOT Emergency Response Guide.
Section VI – Accidental Release Measures
If batteries are spilled and damaged, they should be disposed of according to the disposal section.
Section VII – Handling and Storage
The battery pack and enclosed cells should not be opened, disassembled, crushed, burned, or exposed to high temperatures (> 60o C or 140o F).
Section VIII – Exposure Controls / Personal Protection
No personal protection is required during normal handling and use. Exposure to the ingredients contained within the cells within the battery pack could be harmful under some circumstances. In case of exposure to cell contents, wash affected area for at least 15 minutes with generous amounts of water and seek medical attention.
Section IX – Physical and Chemical Properties
These batteries are solid articles. Properties such as odor, pH, vapor pressure, solubility, etc. are not applicable. There are no known toxicological properties of the batteries during normal handling and use.
Section X – Stability and Reactivity
Reactivity: None during normal handling and use Incompatibility: None during normal handling and use Hazardous Decomposition Products: None during normal handling and use Conditions to Avoid: The battery pack and enclosed cells should not be opened,
disassembled, crushed, burned, or exposed to high temperatures.
Section XI – Toxicological Information
There are no known toxicological properties of the batteries during normal handling and use.
Section XII – Ecological Information
There are no known ecological risks of the batteries during normal handling and use.
Section XIII – Disposal
All Rose Electronics Li-ion batteries contain recyclable materials. Recycling options available in your local area should be considered when disposing of this product. Do not dispose of in fire. Rose Lithium ion batteries are classified by the federal government as non-hazardous waste and are safe for disposal in the normal municipal waste stream. These batteries, however, do contain recyclable materials and are accepted for recycling by the Call2Recyce Battery Recycling Program. Please call 1­800-8-BATTERY for information on recycling your used Lithium Ion battery or go to the Call2Recycle website at www.rbrc.org for additional information.
Section XIV – Transport Information
These cells (and therefore the 1-cell pack) have been tested and pass in accordance with the United Nations Manual of Tests and Criteria, Part III subjection 38.3. Not regulated for transport under Special Provision 34 of the Canadian Transport of Dangerous Goods Regulations
2030 Ringwood Avenue ● San Jose, CA 95131 ● 800-632-4789 ● www.rosebatteries.com