Shure A96F User Manual

Model A96F
User Guide
MODEL A96F LINE MATCHING TRANSFORMER
This transformer connects microphones with an XLR-type connector to the 3.5 mm (1/8 in.) inputs found on camcorders and other recording devices. It increases the signal level from the microphone, provides a balanced input, and prevents distortion due to the d.c. bias typically found in camcorder microphone inputs.
IMPEDANCE SELECTION
The A96F can be modified for microphones rated at 150  This modification is o nly necessary if the output level from the A96F is insufficient for your recording device. Use the following steps:
1. Access the wiring in the XLR plug element of the A96F by loosening the
screw and sliding the plug from the case.
2. Unsolder the RED lead from pin 2. Insulate the bare wire at the end of the
lead with the insulator from the YELLOW lead.
3. Solder the YELLOW lead to pin 2.
4. Rotate the plug element three turns to twist the leads and replace the ele-
ment in the housing. Replace the screw.
©2009 Shure Incorporated 27D2991 (Rev. 5)
Printed in U.S.A.
TROUBLESHOOTING
RING
TIP
Remove wire here
RED
BLUE
600
150
2.5 k
YELLOW
WHITE
SHIELD
BLACK
+
3
2
1
RING
SLEEVE
TIP
WIRING DIAGRAM
1. Unscrew the housing from the miniature plug on the A96F to expose the wires inside the connector.
2. Use wire clippers to cut and remove the wire between the tip and ring leads (see figure below). Make sure to remove the wire completely from between the leads so that there is no contact between the tip and ring.
3. Reassemble the plug.
If the microphone still does not work, contact Shure Application Engineering at 1-800-
516-2525. Please have the camcorder user's guide available.
2
Loading...
+ 2 hidden pages