WIRING CONNECTIONS
Refer to Figure 1 and Table 1 below. For unbalanced opera­tion, the GREEN wire is connected to the audio input, the WHITE wire is connected to the audio ground, and the SHIELD is connected to chassis ground. In some cases, au­dio ground and chassis ground will be the same.
For balanced operation, the GREEN wire is connected to the positive audio input, the WHITE wire is connected to the negative audio input, and the SHIELD is connected to chas­sis ground.
IMPEDANCE SWITCH PRESS-TO-TALK SWITCH
GREEN
YELLOW
SHURE MODEL 450 SERIES II PAGING AND DISPATCHING MICROPHONE
The Shure Model 450 Series II is a high output dynamic mi­crophone designed for paging and dispatching applications. This extremely rugged microphone features an omnidirec­tional pickup pattern and a frequency response tailored for optimum speech intelligibility. It also includes an impedance selection switch and a locking press-to-talk switch. The press-to-talk switch can be converted to a monitor/transmit switch with the Shure RK199S Split-Bar Conversion Kit.
Features
Dual impedance
Locking press-to-talk switch
Rugged ARMO-DURR base and case
Adjustable height
Optional monitor/transmit switch conversion kit
PRESS-TO-TALK SWITCH OPERATION
To operate the control bar as a press–to–talk switch, simply hold it down and begin speaking. When you are finished speaking, release the control bar.
To lock the control bar in the “on” position, press it down and pull it forward. To unlock the control bar, push it back and re­lease it.
IMPEDANCE SELECTION
To select high or low impedance, move the impedance selec­tion switch, located under the microphone base, to either the HIGH or LO position. The switch is factory pre–set to LO.
Shure recommends the low impedance setting if long lengths of cable are used, or if severe hum is encountered. Use Shure A95 Line Matching Transformers to match a low impedance (300 ) microphone line to a high impedance amplifier input.
BLACK
12 3
BLACK RED GREEN WHITE
SHIELD
ORANGE
RED
HILO
GREEN
WHITE
WIRING DIAGRAM
FIGURE 1
Table 1. Typical Cable-to-Connector Wiring
INPUT TYPE WIRE
UNBALANCED WHITE AUDIO GROUND PIN 3 SLEEVE
BALANCED WHITE AUDIO – PIN 3 RING
COLOR
GREEN AUDIO PIN 2 TIP
SHIELD CHASSIS GROUND PIN 1 SLEEVE
GREEN AUDIO + PIN 2 TIP
SHIELD CHASSIS GROUND PIN 1 SLEEVE
FUNCTION XLR
CONNECTOR
1/4 IN.
PHONE JACK
NOTE: The RED and BLACK leads are not part of the audio
circuit. These wires provide a contact closure when the press­to-talk switch is depressed. This closure may be used to con­trol an external relay or a transmit/receive circuit.
CHANGING PTT CIRCUIT TO NORMALLY OPEN
Using microphones in parallel requires a normally open mi­crophone circuit. To modify the press–to–talk switch so that it provides a normally open circuit, proceed as follows:
1. Remove the screws, washers, and bottom plate from the microphone.
2. Unsolder the black, red, and white leads from the terminal of the press–to–talk switch (see Figure 1). Make sure these leads are still soldered together. If necessary, resolder them and insulate the connection.
3. Replace the bottom plate and secure it with the screws and washers removed in Step 1.
2005, Shure Incorporated 27C2917 (Rev. 3)
Printed in U.S.A.
TRANSMIT/MONITOR SWITCH CONVERSION KIT
When the optional split-bar Transmit/Monitor Switch Conver­sion Kit is installed, the Monitor bar must be depressed before the Transmit switch can be depressed, requiring the operator to verify that the channel is open before transmitting. The Monitor bar can be locked in the “on” position. The Transmit bar is momentary and cannot be locked.
NOTE: Transceiver wiring information must be obtained from the transceiver schematic and/or the manufacturer.
SPECIFICATIONS
Type
Dynamic
Frequency Response
200 to 5,000 Hz (see Figure 2)
TYPICAL FREQUENCY RESPONSE
FIGURE 2
Polar Pattern
Omnidirectional
Impedance (at 1,000 Hz)
High Impedance: 30,000 Low Impedance: 225
Recommended Load Impedance
High Impedance: 100,000 Low Impedance: 1,000
Output Level (at 1,000 Hz, Open Circuit Voltage)
High Impedance Low Impedance
–35.0 dBV/Pa* –57.0 dBV/Pa*
(17.8 mV) (1.4 mV)
*1 Pa = 94 dB SPL
Switches
Locking Press-to-Talk Switch: Activates microphone cir­cuit and an external relay or control circuit. The micro­phone circuit is normally shorted.
Impedance Selection Switch: Double-pole, double-throw slide switch located in the base of the microphone.
Cable
2.1 m (7 ft.) four-conductor, two conductors shielded, non-detachable
Case
Two-tone gray ARMO-DUR
R
OVERALL DIMENSIONS
FIGURE 3
Net Weight
737 grams (1 lb., 10 oz.)
Shipping Weight
1020 grams (2 lb., 4 oz.)
Certification
Conforms to European Union directives, eligible to bear CE marking; meets European Union EMC Immunity Re­quirements (EN 50082–1, 1992).
REPLACEMENT PARTS
Cartridge R96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable C31C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
On/Off Switch RK141S. . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONAL ACCESSORIES
Transmit/Monitor Split-Bar Switch Kit RK199S. . . . . . . .
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446 Europe, Middle East, Africa: Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414 Asia, Pacific: Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055